Development of an immunochromatographic assay based on carbon nanoparticles for the determination of the phytoregulator forchlorfenuron

被引:68
作者
Suarez-Pantaleon, Celia [1 ]
Wichers, Jan [2 ]
Abad-Somovilla, Antonio [3 ]
van Amerongen, Aart [2 ]
Abad-Fuentes, Antonio [1 ]
机构
[1] IATA CSIC, Dept Biotechnol, Valencia 46980, Spain
[2] Wageningen UR Food & Biobased Res, Biomol Sensing & Diagnost, NL-6700 AA Wageningen, Netherlands
[3] Univ Valencia, Dept Organ Chem, E-46100 Valencia, Spain
关键词
CPPU; Hapten; Immunoreactive strips; Lateral flow immunoassay; Carbon nanoparticles; Immunosensing; LATERAL FLOW IMMUNOASSAY; ANTIBODY-BASED IMMUNOASSAY; COMPUTER IMAGE-ANALYSIS; RAPID DETECTION; SENSITIVE DETECTION; STRIP TEST; VALIDATION; BIOSENSOR; LABEL; DIAGNOSIS;
D O I
10.1016/j.bios.2012.11.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Rapid analytical methods enabling the determination of diverse targets are essential in a number of research areas, from clinical diagnostics to feed and food quality and safety. Herein, the development of a quantitative immunochromatographic assay for the detection of the synthetic phytoregulator forchlorfenuron (CPPU) is described. The competitive lateral flow immunoassay (LFIA) was based on the immobilization onto a nitrocellulose membrane of an ovalbumin-CPPU conjugate (test line) and on the use of an immunodetection ligand consisting of carbon nanoparticles labeled with an anti-CPPU monoclonal antibody through interaction with a secondary antibody. The presence of CPPU in horticultural samples was visually interpreted by the decrease in the black signal intensity of the test line, according to the competitive character of the format. The quantitative determination of the analyte was easily performed by a two-step procedure consisting of flatbed scanning of the strips followed by computer-based image analysis of the pixel gray volumes of the test lines. Under optimized conditions, the immunochromatographic test afforded a limit of quantification in buffer of 89 ng/L. The accuracy of the strip test was assessed by the analysis of fruit samples with incurred residues, and the obtained results were compared with those derived from two reference methods, ELISA and HPLC. The LOQ of the CPPU-specific LFIA in kiwifruits and grapes was established at 33.4 mu g/kg. The excellent analytical performance of the developed strip test demonstrates the potential of immunochromatographic assays for the quantitative monitoring of small organic molecules in complex matrices. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 53 条
  • [1] Principles of some novel rapid dipstick methods for detection and characterization of verotoxigenic Escherichia coli
    Aldus, CF
    van Amerongen, A
    Ariëns, RMC
    Peck, MW
    Wichers, JH
    Wyatt, GM
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2003, 95 (02) : 380 - 389
  • [2] Usefulness of pneumococcal antigen detection in pleural fluid samples by immunochromatographic assay for diagnosis of pneumococcal pneumonia
    Andreo, F.
    Dominguez, J.
    Ruiz-Manzano, J.
    Prat, C.
    Blanco, S.
    Lores, L.
    Sanchez, M. D.
    Latorre, I.
    Gimenez, M.
    Ausina, V.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2006, 12 (07) : 682 - 684
  • [3] Microfluidic immunosensor systems
    Bange, A
    Halsall, HB
    Heineman, WR
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) : 2488 - 2503
  • [4] Immunochromatographic strip test for detection of genus Cronobacter
    Blazkova, Martina
    Javurkova, Barbora
    Fukal, Ladislav
    Rauch, Pavel
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) : 2828 - 2834
  • [5] Strip-based immunoassay for rapid detection of thiabendazole
    Blazkova, Martina
    Rauch, Pavel
    Fukal, Ladislav
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) : 2122 - 2128
  • [6] Immunochromatographic colloidal carbon-based assay for detection of methiocarb in surface water
    Blazkova, Martina
    Mickova-Holubova, Barbora
    Rauch, Pavel
    Fukal, Ladislav
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) : 753 - 758
  • [7] Development and validation of a lateral flow device for the detection of nicarbazin contamination in poultry feeds
    Campbell, Katrina
    Fodey, Terence
    Flint, Jonathan
    Danks, Christopher
    Danaher, Martin
    O'Keeffe, Michael
    Kennedy, D. Glenn
    Elliott, Christopher
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (06) : 2497 - 2503
  • [8] European Commission, 2006, OFFICIAL J EUROPEA L, VL25, P24
  • [9] Strip-based immunochromatographic assay using specific egg yolk antibodies for rapid detection of morphine in urine samples
    Gandhi, Sonu
    Caplash, Neena
    Sharma, Prince
    Suri, C. Raman
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (02) : 502 - 505
  • [10] Analytical sensitivity limits for lateral flow immunoassays
    Gordon, Julian
    Michel, Gerd