Array Biosensor: Optical and Fluidics Systems

被引:77
作者
Feldstein, Mark J. [1 ]
Golden, Joel P. [1 ]
Rowe, Chris A. [1 ]
MacCraith, Brian D. [2 ]
Ligler, Frances S. [1 ]
机构
[1] Naval Res Lab, Ctr Bio Mol Sci & Engn, Washington, DC 20375 USA
[2] Dublin City Univ, Dept Phys, Dublin 9, Ireland
关键词
array biosensor; automation; CCD imaging; fluorescence imaging; antibody patterning; waveguide;
D O I
10.1023/A:1009900608757
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical and fluidics systems have been developed as central components for an automated array biosensor. Disposable planar waveguides are patterned with immobilized capture antibodies using a physically isolated patterning (PIP) method. The PIP method enables simultaneous deposition of several antibodies and completely circumvents cross-immobilization problems encountered with other array deposition processes. A multichannel fluidics cell allows numerous assays to be performed on the patterned waveguide. The sensing arrays are optically interrogated using a diode laser with a tailored output to optimize coupling to and maximize excitation uniformity within the waveguide. A patterned cladding is employed to optically isolate the waveguide from perturbations induced by the permanently attached flow cells. Compact optics image the evanescently excited fluorescence onto a large area, cooled CCD array. The image data is processed and automated signal analysis corrects for local background and noise variations.
引用
收藏
页码:139 / 153
页数:15
相关论文
共 28 条
[11]   Novel bioaffinity sensors for trace analysis based on luminescence excitation by planar waveguides [J].
Duveneck, GL ;
Pawlak, M ;
Neuschafer, D ;
Bar, E ;
Budach, W ;
Pieles, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :88-95
[12]   LIGHT-DIRECTED, SPATIALLY ADDRESSABLE PARALLEL CHEMICAL SYNTHESIS [J].
FODOR, SPA ;
READ, JL ;
PIRRUNG, MC ;
STRYER, L ;
LU, AT ;
SOLAS, D .
SCIENCE, 1991, 251 (4995) :767-773
[13]  
Golden J.P., 1998, US patent, Patent No. [5827748, 5,827,748]
[14]  
Herron J.N., 1996, US patent, Patent No. [5512492, 5,512,492]
[15]  
Herron J.N., 1997, US patent, Patent No. [5677196, 5,677,196]
[16]  
Kapur R, 1996, J BIOMED MATER RES, V33, P205, DOI 10.1002/(SICI)1097-4636(199624)33:4<205::AID-JBM1>3.0.CO
[17]  
2-T
[18]  
Katerkamp A., 1997, [No title captured], Patent No. [WO 9802732, 9802732]
[19]   Two- and three-dimensional crystallization of polymeric microspheres by micromolding in capillaries [J].
Kim, E ;
Xia, YN ;
Whitesides, GM .
ADVANCED MATERIALS, 1996, 8 (03) :245-&
[20]   Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor [J].
King, KD ;
Anderson, GP ;
Bullock, KE ;
Regina, MJ ;
Saaski, EW ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (02) :163-170