Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography

被引:33
作者
Freitas, Deborah Queiroz [1 ]
Vasconcelos, Taruska Ventorini [2 ]
Noujeim, Marcel [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Av Limeira 901, BR-13414903 Piracicaba, SP, Brazil
[2] Univ Fed Bahia, Sch Dent, Div Oral Radiol, Rua Araujo Pinho 62, BR-40110040 Salvador, BA, Brazil
[3] Univ Texas Hlth Sci Ctr San Antonio, Div Oral & Maxillofacial Radiol, Dept Comprehens Dent, 7707 Floyd Curl Dr, San Antonio, TX 78229 USA
关键词
Vertical root fracture; Cone beam computed tomography; Artifact; Kilovoltage; Artifact reduction tool; PERIAPICAL RADIOGRAPHY; REDUCTION ALGORITHM; ZIRCONIUM; ACCURACY; TITANIUM; EFFICACY; CBCT;
D O I
10.1007/s00784-018-2558-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo evaluate the influence of artifacts produced by zirconium implant on the diagnosis of vertical root fracture (VRF) in teeth close and distant to the implant in cone beam computed tomography (CBCT) images. We also determined if kilovoltage (kVp) and metal artifact reduction (MAR) tool could influence this diagnosis.Materials and methodsTwenty single-root teeth were divided in control and fractured groups (n=10). The teeth were randomly positioned in the first and second and right and left pre-molar alveoli of a dry human mandible. CBCT exams were acquired using a ProMax 3D unit with varying kVp (70, 80, or 90kVp), with or without MAR, and with and without a zirconium implant placed in the alveolus of first right molar. The images were evaluated by five observers. The area under the receiver operating characteristic curve (ROC), sensitivity, and specificity were calculated and compared by analysis of variance with a significance level of 5%.ResultsIn general, ROC and sensitivity were not affected by the factors studied (p>0.05). The main effects occurred in specificity; when implant was used without MAR, the values were lower for tooth 45 for all kVps (p=0.0001).ConclusionsArtifacts produced in the vicinity of teeth with suspected VRF impair the diagnosis by decreasing the specificity, because they can mimic the VRF line generating false positives. However, MAR improves the specificity, being its use recommended when metallic objects are present near teeth with suspected VRF.Clinical RelevanceSince nowadays, many patients who undergo CBCT show implants and they definitively produce artifacts, it is important to evaluate the influence of such artifacts in the diagnosis of teeth that are close to the generator-artifact object.
引用
收藏
页码:1263 / 1270
页数:8
相关论文
共 36 条
  • [1] [Anonymous], 2012, RAD PROT CON BEAM CT
  • [2] Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth
    Bechara, B.
    McMahan, C. Alex
    Moore, W. S.
    Noujeim, M.
    Teixeira, F. B.
    Geha, H.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [3] Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts
    Bezerra, I. S. Q.
    Neves, F. S.
    Vasconcelos, T. V.
    Ambrosano, G. M. B.
    Freitas, D. Q.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
  • [4] A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth
    Brady, E.
    Mannocci, F.
    Brown, J.
    Wilson, R.
    Patel, S.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (08) : 735 - 746
  • [5] Bragatto Fernanda Paula, 2016, J Conserv Dent, V19, P573
  • [6] Detection of Vertical Root Fractures by Using Cone-beam Computed Tomography: A Clinical Study
    Edlund, Mitchell
    Nair, Madhu K.
    Nair, Umadevi P.
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (06) : 768 - 772
  • [7] Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts
    Ferreira, L. M.
    Visconti, M. A. P. G.
    Nascimento, H. A.
    Dallemolle, R. R.
    Ambrosano, G. M.
    Freitas, D. Q.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (05)
  • [8] Magnitude of cone beam CT image artifacts related to zirconium and titanium implants: impact on image quality
    Fontenele, Rocharles C.
    Nascimento, Eduarda H. L.
    Vasconcelos, Taruska V.
    Noujeim, Marcel
    Freitas, Deborah Q.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (06)
  • [9] Optimization of Tube Current in Cone-beam Computed Tomography for the Detection of Vertical Root Fractures with Different Intracanal Materials
    Gaeta-Araujo, Hugo
    Silva de Souza, Gabriela Queiroz
    Freitas, Deborah Queiroz
    de Oliveira-Santos, Christiano
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (10) : 1668 - 1673
  • [10] Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings
    Helvacioglu-Yigit, Dilek
    Kocasarac, Husniye Demirturk
    Bechara, Boulos
    Noujeim, Marcel