Validation of a high throughput method for serum/plasma testosterone using liquid chromatography tandem mass spectrometry (LC-MS/MS)

被引:49
作者
Singh, Ravinder J. [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Lab Med & Pathol, Rochester, MN 55905 USA
关键词
Testosterone; Tandem mass spectrometry; Immunoassay; Precision; Coefficient of variation; Androgen;
D O I
10.1016/j.steroids.2008.07.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Testosterone, the major androgenic hormone in humans, is commonly measured to aid in the diagnosis of clinical conditions related to its excess or deficiency. in addition, testosterone measurements are used to monitor testosterone replacement-, or antiandrogen therapy. Most commonly, automated direct immunoassays have been used to measure testosterone in human serum. Their advantage compared with other methodologies, lies in high- and rapid sample throughput with minimal human intervention. However, many automated testosterone immunoassays suffer from poor accuracy at the low concentration levels (<50 ng/dL) seen in women and children, or in men undergoing anti-androgen therapy. Our objective was to develop a LC-MS/MS method which measures testosterone in human serum while fulfilling the following criteria: Rapid pre-analytical sample processing with minimal manual sample manipulation; Minimize sample volume requirements; Accurate, precise and unambiguous measurement; Functional sensitivity of 5-10 ng/dL; Sample throughput of at least 30 samples per hour. Our validation criteria for precision, accuracy, and linearity was to have accuracy and linearity within mean limits of +/- 10%; Intra and inter-assay precision of <15% throughout the reporting range. We also wanted to compare our results to a previously validated LC-MS/MS assay which utilized a manual liquid-liquid extraction and to an automated commercial immunoassay (Bayer ACS:180). We describe here a sensitive and rapid testosterone assay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing on-line sample extraction and multiplexing. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:1339 / 1344
页数:6
相关论文
共 17 条
[1]  
Albrecht Lindsey, 2007, Pediatr Endocrinol Rev, V5 Suppl 1, P599
[2]   Column-switching LC-MS/MS analysis for quantitative determination of testosterone in human serum [J].
Borrey, Danielle ;
Moerman, Elke ;
Cockx, An ;
Engelrelst, Veronique ;
Langlois, Michel R. .
CLINICA CHIMICA ACTA, 2007, 382 (1-2) :134-137
[3]  
Botelho JC, 2008, CLIN CHEM, V54, pA122
[4]  
Cao Z, 2008, CLIN CHEM, V54, pA113
[5]   The vallidity of androgen assays [J].
Carruthers, Malcolm ;
Trinick, Tom R. ;
Wheeler, Michael J. .
AGING MALE, 2007, 10 (03) :165-172
[6]   Reproducibility of serum sex steroid assays in men by RIA and mass spectrometry [J].
Hsing, Ann W. ;
Stanczyk, Frank Z. ;
Belanger, Alain ;
Schroeder, Paul ;
Chang, Lilly ;
Falk, Roni T. ;
Fears, Thomas R. .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2007, 16 (05) :1004-1008
[7]  
JOELLE T, 2003, CLIN CHEM, V49, P1381
[8]   Measurement of serum testosterone in women; what should we do? [J].
Kane, John ;
Middle, Jonathan ;
Cawood, Marion .
ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 :5-15
[9]   Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone [J].
Kushnir, MM ;
Rockwood, AL ;
Roberts, WL ;
Pattison, EG ;
Bunker, AM ;
Fitzgerald, RL ;
Meikle, AW .
CLINICAL CHEMISTRY, 2006, 52 (01) :120-128
[10]   Low serum testosterone assayed by liquid chromatography-tandem mass spectrometry.: Comparison with five immunoassay techniques [J].
Moal, Valerie ;
Mathieu, Elisabeth ;
Reynier, Pascal ;
Malthiery, Yves ;
Gallois, Yves .
CLINICA CHIMICA ACTA, 2007, 386 (1-2) :12-19