Improvement of Flow Fairness in Quantized Congestion Notification for Data Center Networks

被引:6
作者
Hayashi, Yuki [1 ]
Itsumi, Hayato [1 ]
Yamamoto, Miki [2 ]
机构
[1] Kansai Univ, Grad Sch Sci & Engn, Suita, Osaka 5648680, Japan
[2] Kansai Univ, Fac Engn Sci, Suita, Osaka 5648680, Japan
关键词
QCN; data center; LAN-SAN integration; congestion control;
D O I
10.1587/transcom.E96.B.99
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In large-scale data centers, two types of network are implemented: local area networks (LANs) and storage area networks (SANs). To achieve simple network management, integration of these two networks by Ethernet technology is of great interest. A SAN requires a significantly low frame loss rate. To integrate LANs and SANs, a multi-hop Ethernet configuration is generally used, and congestion may occur in traffic hot spots. Therefore, layer-2 congestion control that prevents frame loss in multi-hop Ethernet, Quantized Congestion Notification (QCN), is now discussed in IEEE 802.1Qau. In this paper, we evaluate QCN's throughput performance and reveal a technical problem with fairness among active flows. We also propose Adaptive BC_LIMIT for QCN where BC_LIMIT is adaptively decided according to current transmission rate of flows. Simulation results show that our proposed method significantly improves fairness among QCN flows.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 17 条
  • [1] Alizadeh M., 2010, P ACM SIGCOMM AUG
  • [2] Alizadeh M., 2008, P ANN ALL C SEPT
  • [3] Chen Y., 2009, P ACM WREN AUG
  • [4] Hayashi Y., 2010, NS2010288 IEICE
  • [5] Hayashi Y., 2011, P IEEE DCPERF JUN
  • [6] Hays R., 2007, IEEE 802 3 HSSG INT
  • [7] Jiang J., 2007, P IEEE INFOCOM
  • [8] Jiang J., 2008, P INT C COMM ICC MAY
  • [9] Kabbani A., 2010, P IEEE HOT INT AUG
  • [10] Pan R., 2001, QCN PSEUDE CODE VERS