Pulsed-wire system for undulator measurement

被引:0
作者
Li, Zhiqiang [1 ,2 ]
Lu, Huihua [1 ]
Chen, Wan [1 ]
Li, Yuhui [1 ]
Huang, Yongsheng [1 ]
Liu, Peng [1 ]
Gong, Lingling [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Lab Particle Accelerat Phys & Technol, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Magnetic field measurement; Undulator; Pulsed wire; Integral field measurement; Displacement;
D O I
10.1007/s41605-021-00309-x
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose More undulators are required of HEPS in future. The efficiency of traditional Hall-probe measurement method is relatively low, which is difficult to meet the measurement needs of large quantities of undulators. In order to improve debugging efficiency, the pulsed-wire method is required further improvement. Methods A pulsed-wire method is an effective method to achieve magnetic field distribution through narrow aperture of undulator. The pulsed-wire method works by sending a square current pulse through the wire, which will induce an interaction with the magnetic field due to the Lorentz force. This force causes the wire to be displaced, and this displacement travels along the wire in both directions as an acoustic wave. Measurement of the displacement in the wire over time using a motion detector yields the first or second integrals of the magnetic field. Results The accuracy and repeatability are the important requirements. The repeatability of the first field integral of the pulsed-wire system is better than 1 parts per thousand which meets the design requirements. Conclusions This paper illustrates the effectiveness of pulsed-wire system by test results. Through comparison, the accuracy of the system is proved. It provides a new important measurement system for undulators in future.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 10 条
  • [1] Fan T. C., 2001, PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268), P2775, DOI 10.1109/PAC.2001.987903
  • [2] A systematic study on the pulsed wire system for magnetic field measurements on the long undulator with high field
    Fan, TC
    Hwang, CS
    Chang, CH
    Hsu, IC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) : 1430 - 1432
  • [3] Li Yu, 2007, Nuclear Techniques, V30, P815
  • [4] High-accuracy stretched-wire measurement system for cryogenic permanent magnet undulator (CPMU) in High Energy Photon Source (HEPS)
    Li, Zhiqiang
    Chen, Wan
    Lu, Huihua
    Gong, Lingling
    Sun, Shuchen
    Zhang, Lei
    Yang, Yufeng
    Li, Xiaoyu
    Zhao, Shutao
    Zhang, Xiangzhen
    [J]. RADIATION DETECTION TECHNOLOGY AND METHODS, 2020, 4 (04) : 492 - 496
  • [5] Ngotta P., 2019, IMMW
  • [6] Tong Qu., 1995, HIGH POWER LASER PAR, V7, P165
  • [7] Development of pulsed wire field integral measurement system
    Wang T.
    Jia Q.
    [J]. Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (10): : 2421 - 2424
  • [9] Warren RW., 1990, NUCL INSTRUM METH A, V292, P794
  • [10] Preliminary R&D of vibrating wire alignment technique for HEPS
    Wu Lei
    Wang Xiao-Long
    Li Chun-Hua
    Qu Hua-Min
    [J]. CHINESE PHYSICS C, 2015, 39 (08)