Multiobjective optimization framework for landmark measurement error correction in three-dimensional cephalometric tomography

被引:10
|
作者
DeCesare, A. [1 ]
Secanell, M. [1 ]
Lagravere, M. O. [2 ]
Carey, J. [1 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB T6G 1C9, Canada
[2] Univ Alberta, Fac Med & Dent, Dept Dent, Orthodont Grad Program, Edmonton, AB T6G 1C9, Canada
关键词
cone beam computed tomography; orthodontics; maxillary expansion treatment; landmark optimization procedure; BEAM COMPUTERIZED-TOMOGRAPHY; PLANE ORIENTATION; ORTHOGNATHIC SURGERY; MAXILLARY EXPANSION; CRANIAL BASE; CLEFT-LIP; GROWTH; IMAGES; SUPERIMPOSITION; RELIABILITY;
D O I
10.1259/dmfr.20130035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study is to minimize errors that occur when using a four vs six landmark superimpositioning method in the cranial base to define the co-ordinate system. Cone beam CT volumetric data from ten patients were used for this study. Co-ordinate system transformations were performed. A co-ordinate system was constructed using two planes defined by four anatomical landmarks located by an orthodontist. A second co-ordinate system was constructed using four anatomical landmarks that are corrected using a numerical optimization algorithm for any landmark location operator error using information from six landmarks. The optimization algorithm minimizes the relative distance and angle between the known fixed points in the two images to find the correction. Measurement errors and co-ordinates in all axes were obtained for each co-ordinate system. Significant improvement is observed after using the landmark correction algorithm to position the final co-ordinate system. The errors found in a previous study are significantly reduced. Errors found were between 1 mm and 2 mm. When analysing real patient data, it was found that the 6-point correction algorithm reduced errors between images and increased intrapoint reliability. A novel method of optimizing the overlay of three-dimensional images using a 6-point correction algorithm was introduced and examined. This method demonstrated greater reliability and reproducibility than the previous 4-point correction algorithm.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Cephalometric Screening Assessment for Superior Airway Space Narrowing-Added Value of Three-Dimensional Imaging
    Meisgeier, Axel
    Duerrschnabel, Florian
    Pienkohs, Simon
    Weiser, Annabell
    Neff, Andreas
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (09)
  • [42] A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry
    Janalt Damstra
    Zacharias Fourie
    Marnix De Wit
    Yijin Ren
    Clinical Oral Investigations, 2012, 16 : 285 - 294
  • [43] Three-dimensional regional displacement after surgical-orthodontic correction of Class III malocclusion
    Koerich, L.
    Ruellas, A. C. O.
    Paniagua, B.
    Styner, M.
    Turvey, T.
    Cevidanes, L. H. S.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2016, 19 (02) : 65 - 73
  • [44] A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry
    Damstra, Janalt
    Fourie, Zacharias
    De Wit, Marnix
    Ren, Yijin
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (01) : 285 - 294
  • [45] Repeatability and reproducibility of landmarks-a three-dimensional computed tomography study
    Titiz, Irem
    Laubinger, Michala
    Keller, Thomas
    Hertrich, Klaus
    Hirschfelder, Ursula
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (03) : 276 - 286
  • [46] Application of three-dimensional computed tomography in craniofacial clinical practice and research
    Anderson, P. J.
    Yong, R.
    Surman, T. L.
    Rajion, Z. A.
    Ranjitkar, S.
    AUSTRALIAN DENTAL JOURNAL, 2014, 59 : 174 - 185
  • [47] Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo
    Chien, P. C.
    Parks, E. T.
    Eraso, F.
    Hartsfield, J. K., Jr.
    Roberts, W. E.
    Ofner, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) : 262 - 273
  • [48] Evaluating the Anatomical Traits of Lip on Three-Dimensional Computed Tomography Images
    Babacan, Serdar
    Isiklar, Sefa
    Kafa, Ilker Mustafa
    Gokalp, Gokhan
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (02) : E163 - E166
  • [49] Head positioning in a cone beam computed tomography unit and the effect on accuracy of the three-dimensional surface mode
    Stamatakis, Harry C.
    Steegman, Ralph
    Dusseldorp, Joost
    Ren, Yijin
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2019, 127 (01) : 72 - 80
  • [50] Reproducibility of three-dimensional posterior cranial base angles using low-dose computed tomography
    Olszewski, R.
    Frison, L.
    Schoenarts, N.
    Khonsari, R. H.
    Odri, G. A.
    Zech, F.
    Reychler, H.
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2407 - 2414