Long-term outcomes after valve replacement for low-gradient aortic stenosis - Impact of prosthesis-patient mismatch

被引:100
|
作者
Kulik, Alexander
Burwash, Ian G.
Kapila, Varun
Mesana, Thierry G.
Ruel, Marc
机构
[1] Univ Ottawa, Inst Heart, Div Cardiac Surg, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Div Cardiol, Ottawa, ON K1Y 4W7, Canada
[3] Univ Ottawa, Dept Epidemiol, Ottawa, ON K1Y 4W7, Canada
关键词
aortic stenosis; aortic valve replacement; prosthesis-patient mismatch;
D O I
10.1161/CIRCULATIONAHA.105.001180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The long-term outcomes of patients with low-gradient aortic stenosis (LGAS) after aortic valve replacement (AVR) are poorly defined. The purpose of this study was to define the long-term outcomes of LGAS patients after AVR and to evaluate the potential impact of prosthesis-patient mismatch (PPM) in these patients. Methods and Results - A cohort of 664 patients undergoing AVR for aortic stenosis after 1990 were followed-up prospectively with annual clinical assessment and echocardiography (total follow-up 3447 patient-years; mean follow- up 5.2 +/- 3.3 years). LGAS was defined as an aortic valve area < 1.2 cm(2), a mean transvalvular pressure gradient < 40 mm Hg, and a left ventricular (LV) ejection fraction < 50%, and was present in 79 patients. Rates and correlates of survival, freedom from congestive heart failure (CHF), and LV mass regression after AVR were determined using multivariate regression methods. Ten-year survival and freedom from CHF after AVR were 72.7 +/- 7.5% and 68.2 +/- 9.5%, respectively, for patients with LGAS, compared with 89.6 +/- 1.8% and 84.1 +/- 4.2% for patients without LGAS (hazard ratio [HR] for death and postoperative CHF, 3.1 +/- 1.1 and 2.7 +/- 0.9, respectively; P < 0.01). In LGAS patients, PPM, defined as an indexed effective orifice area <= 0.85 cm(2)/ m(2), was independently associated with increased rates of CHF ( HR, 3.6 +/- 2.2; P = 0.039), impaired LV mass regression (P = 0.037), and a trend toward increased late mortality (HR, 3.0 +/- 1.9; P = 0.084). Conclusions - Patients with LGAS have worse long-term outcomes after AVR compared with patients without LGAS. PPM adversely affects the long-term outcomes of LGAS patients and should be avoided in this population.
引用
收藏
页码:I553 / I558
页数:6
相关论文
共 50 条
  • [1] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [2] Effect of Prosthesis-Patient Mismatch on Long-Term Clinical Outcomes After Bioprosthetic Aortic Valve Replacement
    Dismorr, Michael
    Glaser, Natalie
    Franco-Cereceda, Anders
    Sartipy, Ulrik
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (10) : 964 - 975
  • [3] Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement
    Compagnone, Miriam
    Marchetti, Giulia
    Taglieri, Nevio
    Ghetti, Gabriele
    Bruno, Antonio Giulio
    Orzalkiewicz, Mateusz
    Marrozzini, Cinzia
    Reggiani, Maria-Letizia Bacchi
    Palmerini, Tullio
    Galie, Nazzareno
    Saia, Francesco
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 318 : 27 - 31
  • [4] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [5] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [6] Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality
    Mannacio, Vito
    Mannacio, Luigi
    Mango, Emilo
    Antignano, Anita
    Mottola, Michele
    Caparrotti, Sergio
    Musumeci, Francesco
    Vosa, Carlo
    JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) : 333 - 339
  • [7] Sex-related differences in prosthesis-patient mismatch after surgical aortic valve replacement and long-term outcomes
    Springhetti, Paolo
    Abdoun, Kathia
    Dumont, Eric
    Dagenais, Francois
    Kalavrouziotis, Dimitri
    Mohammadi, Siamak
    Pibarot, Philippe
    Clavel, Marie-Annick
    EUROPEAN HEART JOURNAL, 2025,
  • [8] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [9] Long-term outcomes of measured and predicted prosthesis-patient mismatch following transcatheter aortic valve replacement
    Tomii, Daijiro
    Okuno, Taishi
    Heg, Dik
    Nakase, Masaaki
    Lanz, Jonas
    Praz, Fabien
    Stortecky, Stefan
    Reineke, David
    Windecker, Stephan
    Pilgrim, Thomas
    EUROINTERVENTION, 2023, 19 (09) : 746 - +
  • [10] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60