Assessment of flip angle-TR equivalence for standardized dissolved-phase imaging of the lung with hyperpolarized 129Xe MRI

被引:27
作者
Ruppert, Kai [1 ]
Amzajerdian, Faraz [1 ,2 ]
Hamedani, Hooman [1 ,2 ]
Xin, Yi [1 ,2 ]
Loza, Luis [1 ]
Achekzai, Tahmina [1 ]
Duncan, Ian F. [1 ]
Profka, Harrilla [1 ]
Siddiqui, Sarmad [1 ,2 ]
Pourfathi, Mehrdad [1 ,3 ]
Sertic, Federico [1 ]
Cereda, Maurizio F. [4 ]
Kadlecek, Stephen [1 ]
Rizi, Rahim R. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Elect & Syst Engn, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
dissolved-phase imaging; flip angle-TR equivalence; hyperpolarized xenon-129; lung MRI; XE-129; CHEMICAL-SHIFT; MAGNETIC-RESONANCE; GAS-EXCHANGE; HEALTHY-VOLUNTEERS; RAT LUNG; MODEL; SPECTROSCOPY; NMR; PHYSIOLOGY; ASTHMA;
D O I
10.1002/mrm.27538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of describing the impact of any flip angle-TR combination on the resulting distribution of the hyperpolarized xenon-129 (HXe) dissolved-phase magnetization in the chest using a single virtual parameter, TR90 degrees,equiv. Methods: HXe MRI scans with simultaneous gas- (GP) and dissolved-phase (DP) excitation were performed using 2D projection scans in mechanically ventilated rabbits. Measurements with DP flip angles ranging from 6-90 degrees and TRs ranging from 8.3-500 ms were conducted. DP maps based on acquisitions of similar radio frequency pulse-induced relaxation rates were compared. Results: The observed distribution of the DP magnetization was strongly affected by acquisition flip angle and TR. However, for flip angles up to 60 degrees, measurements with the same radio frequency pulse-induced relaxation rates, resulted in very similar DP images despite the presence of significant macroscopic gas transport processes. For flip angles approaching 90 degrees, the downstream signal component decreased noticeably relative to acquisitions with lower flip angles. Nevertheless, the total DP signal continued to follow an empirically verified conversion equation over the entire investigated parameter range, which yields the equivalent TR of a hypothetical 90 degrees measurement for any experimental flip angle-TR combination. Conclusion: We have introduced a method for converting the flip angle and TR of a given HXe DP measurement to a standardized metric based on the virtual quantity, TR90 degrees,equiv, using their equivalent RF relaxation rates. This conversion permits the comparison of measurements obtained with different pulse sequence types or by different research groups using various acquisition parameters.
引用
收藏
页码:1784 / 1794
页数:11
相关论文
共 38 条
[1]   Quantification of Human Lung Structure and Physiology Using Hyperpolarized 129Xe [J].
Chang, Yulin V. ;
Quirk, James D. ;
Ruset, Iulian C. ;
Atkinson, Jeffrey J. ;
Hersman, F. William ;
Woods, Jason C. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) :339-344
[2]   MOXE: A model of gas exchange for hyperpolarized 129Xe magnetic resonance of the lung [J].
Chang, Yulin V. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) :884-890
[3]   3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosis [J].
Cleveland, Zackary I. ;
Virgincar, Rohan S. ;
Qi, Yi ;
Robertson, Scott H. ;
Degan, Simone ;
Driehuys, Bastiaan .
NMR IN BIOMEDICINE, 2014, 27 (12) :1502-1514
[4]   In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe [J].
Cleveland, Zackary I. ;
Moeller, Harald E. ;
Hedlund, Laurence W. ;
Nouls, John C. ;
Freeman, Matthew S. ;
Qi, Yi ;
Driehuys, Bastiaan .
PLOS ONE, 2012, 7 (02)
[5]   Abnormalities in hyperpolarized 129Xe magnetic resonance imaging and spectroscopy in two patients with pulmonary vascular disease [J].
Dahhan, Talal ;
Kaushik, Shiv S. ;
He, Mu ;
Mammarappallil, Joseph G. ;
Tapson, Victor F. ;
McAdams, Holman P. ;
Sporn, Thomas A. ;
Driehuys, Bastiaan ;
Rajagopal, Sudarshan .
PULMONARY CIRCULATION, 2016, 6 (01) :126-131
[6]   Hyperpolarized 129Xe Imaging of the Rat Lung using Spiral IDEAL [J].
Doganay, Ozkan ;
Wade, Trevor ;
Hegarty, Elaine ;
McKenzie, Charles ;
Schulte, Rolf F. ;
Santyr, Giles E. .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) :566-576
[7]   Multiple-Exchange-Time Xenon Polarization Transfer Contrast (MXTC) MRI: Initial Results in Animals and Healthy Volunteers [J].
Dregely, Isabel ;
Ruset, Iulian C. ;
Mata, Jaime F. ;
Ketel, Jeffrey ;
Ketel, Steve ;
Distelbrink, Jan ;
Altes, Talissa A. ;
Mugler, John P., III ;
Miller, G. Wilson ;
Hersman, F. William ;
Ruppert, Kai .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) :943-953
[8]   Hyperpolarized Xenon-129 Gas-Exchange Imaging of Lung Microstructure: First Case Studies in Subjects With Obstructive Lung Disease [J].
Dregely, Isabel ;
Mugler, John P., III ;
Ruset, Iulian C. ;
Altes, Talissa A. ;
Mata, Jaime F. ;
Miller, G. Wilson ;
Ketel, Jeffrey ;
Ketel, Steve ;
Distelbrink, Jan ;
Hersman, F. W. ;
Ruppert, Kai .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1052-1062
[9]   Imaging alveolar-capillary gas transfer using hyperpolarized 129Xe MRI [J].
Driehuys, Bastiaan ;
Cofer, Gary P. ;
Pollaro, Jim ;
Mackel, Julie Boslego ;
Hedlund, Laurence W. ;
Johnson, G. Allan .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (48) :18278-18283
[10]   Hyperpolarized 129Xenon Magnetic Resonance Imaging to Quantify Regional Ventilation Differences in Mild to Moderate Asthma A Prospective Comparison Between Semiautomated Ventilation Defect Percentage Calculation and Pulmonary Function Tests [J].
Ebner, Lukas ;
He, Mu ;
Virgincar, Rohan S. ;
Heacock, Timothy ;
Kaushik, Suryanarayanan S. ;
Freemann, Matthew S. ;
McAdams, H. Page ;
Kraft, Monica ;
Driehuys, Bastiaan .
INVESTIGATIVE RADIOLOGY, 2017, 52 (02) :120-127