Experimental study of the hygrothermal behaviour of External Thermal Insulation Composite Systems (ETICS)

被引:82
作者
Barreira, Eva [1 ]
de Freitas, Vasco P. [1 ]
机构
[1] Univ Porto, Fac Engn, Dept Civil Engn, Bldg Phys Lab LFC, P-4200465 Oporto, Portugal
关键词
External Thermal Insulation Composite Systems (ETICS); Hygrothermal behaviour; In situ" measurements; External surface condensation; Wind-driven rain; SURFACE;
D O I
10.1016/j.buildenv.2013.02.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
External Thermal Insulation Composite Systems - ETICS are, now-a-days, quite common in European buildings, used both in new constructions and refurbishment. Unfortunately, ETICS can have serious problems of biological growth causing the cladding defacement. It is known that biological growth is due to high values of surface moisture content, which results mostly from surface condensation and wind-driven rain. If the drying process is not sufficiently fast, the surface moisture content remains high for longer periods and consequently increases the risk of biological growth. This paper presents the results of a detailed experimental study that was carried out by the Building Physics Laboratory of Porto University (UP), in order to assess the hygrothermal behaviour of facades covered with ETICS, namely to evaluate the influence of orientation on surface humidification, by external condensation and by wind-driven rain. A building located in UP campus, with its four facades facing the cardinal directions, was monitored during one year. The exterior surface parameters under study were temperature, long wave radiation, wind-driven rain and relative humidity. The exterior climate was also measured to evaluate surface condensation. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 18 条
[1]  
[Anonymous], 13 NORW BUILD RES I
[2]   An assessment of facade coatings against colonisation by aerial algae and cyanobacteria [J].
Barberousse, Helene ;
Ruot, Bertrand ;
Yepremian, Claude ;
Boulon, Gilbert .
BUILDING AND ENVIRONMENT, 2007, 42 (07) :2555-2561
[3]  
Barreira E, 2010, P 1 CENTR EUR S CRAC, P289
[4]  
Barreira E, 2011, P 12DBMC INT C DUR B, V1, P393
[5]  
BECKER R., 2003, Journal of Thermal Envelopes and Building Science, V26, P321, DOI [10.1177/1097196303026004001, DOI 10.1177/1097196303026004001]
[6]  
BLAICH J., 1999, La deterioration des batiments - Analyse et prevention
[7]  
Hagentoft C-E., 2001, INTRO BUILDING PHYS
[8]  
HENRIQUES F., 1993, Quantificacao da Chuva Incidente em Paredes
[9]  
Holm A., 2004, P PERF EXT ENV WHOL
[10]   Estimation of mould growth levels on rendered facades based on surface relative humidity and surface temperature measurements [J].
Johansson, Sanne ;
Wadso, Lars ;
Sandin, Kenneth .
BUILDING AND ENVIRONMENT, 2010, 45 (05) :1153-1160