Enhanced removal of Se(VI) from water via pre-corrosion of zero-valent iron using H2O2/HCl: Effect of solution chemistry and mechanism investigation

被引:47
|
作者
Shan, Chao [1 ,3 ]
Chen, Jiajia [1 ]
Yang, Zhe [1 ]
Jia, Huichao [1 ]
Guan, Xiaohong [2 ]
Zhang, Weiming [1 ,3 ]
Pan, Bingcai [1 ,3 ]
机构
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] Tongji Univ, State Key Lab Pollut Control & Resources Reuse, Coll Environm Sci & Engn, Shanghai 200092, Peoples R China
[3] Nanjing Univ, Res Ctr Environm Nanotechnol ReCENT, Nanjing 210023, Jiangsu, Peoples R China
基金
国家重点研发计划; 中国博士后科学基金;
关键词
Selenate; ZVI; Corrosion; Hydrogen peroxide; Adsorption; Reduction; WEAK MAGNETIC-FIELD; NITRATE REDUCTION; ZEROVALENT IRON; SELENATE REMOVAL; AQUEOUS FE2+; ENVIRONMENTAL REMEDIATION; SELENITE REMOVAL; ELEMENTAL IRON; FERRIC-OXIDE; ADSORPTION;
D O I
10.1016/j.watres.2018.01.038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Although the removal of Se(VI) from water by using zero-valent iron (ZVI) is a promising method, passivation of ZVI severely inhibits its performance. To overcome such issue, we proposed an efficient technique to enhance Se(VI) removal via pre-corrosion of ZVI with H2O2/HCl in a short time (15 min). The resultant pcZVI suspension was weakly acidic (pH 4.56) and contained abundant aqueous Fe2+. Fe-57 Mossbauer spectroscopy showed that pcZVI mainly consisted of Fe-0 (66.2%), hydrated ferric oxide (26.3%), and Fe3O4 (7.5%). Efficient removal of Se(VI) from sulfate-rich solution was achieved by pcZVI compared with ZVI (in the absence and presence of H2O2) and acid-pretreated ZVI. Moreover, the efficient removal of Se(VI) by pcZVl sustained over a broad pH range (3-9) due to its strong buffering power. The presence of chloride, carbonate, nitrate, and common cations (Na+, K+, Ca2+, and Mg2+) posed negligible influence on the removal of Se(VI) by pcZVI, while the inhibitory effect induced by sulfate, silicate, and phosphate indicated the significance of Se(VI) adsorption as a prerequisite step for its removal. The consumption of aqueous Fe2+ was associated with Se(VI) removal, and X-ray absorption near edge structure revealed that the main pathway for Se(VI) removal by pcZVI was a stepwise reduction of Se(VI) to Se(IV) and then Se-0 as the dominant final state (78.2%). Moreover, higher electron selectivity of pcZVI was attributed to the enhanced enrichment of Se oxyanions prior to their reduction. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 46 条
  • [21] Effects of physicochemical factors on Cr(VI) removal from leachate by zero-valent iron and α-Fe2O3 nanoparticles
    Liu, T. Y.
    Zhao, L.
    Tan, X.
    Liu, S. J.
    Li, J. J.
    Qi, Y.
    Mao, G. Z.
    WATER SCIENCE AND TECHNOLOGY, 2010, 61 (11) : 2759 - 2767
  • [22] Kaolinite-supported nanoscale zero-valent iron for removal of Pb2+ from aqueous solution: Reactivity, characterization and mechanism
    Zhang, Xin
    Lin, Shen
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravendra
    WATER RESEARCH, 2011, 45 (11) : 3481 - 3488
  • [23] Integration of nanosized zero-valent iron particles addition with UV/H2O2 process for purification of azo dye Acid Black 24 solution
    Shu, Hung-Yee
    Chang, Ming-Chin
    Chang, Chi-Chen
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) : 1178 - 1184
  • [24] An insight in magnetic field enhanced zero-valent iron/H2O2 Fenton-like systems: Critical role and evolution of the pristine iron oxides layer
    Xiang, Wei
    Zhang, Beiping
    Zhou, Tao
    Wu, Xiaohui
    Mao, Juan
    SCIENTIFIC REPORTS, 2016, 6
  • [25] An insight in magnetic field enhanced zero-valent iron/H2O2 Fenton-like systems: Critical role and evolution of the pristine iron oxides layer
    Wei Xiang
    Beiping Zhang
    Tao Zhou
    Xiaohui Wu
    Juan Mao
    Scientific Reports, 6
  • [26] Investigation of zero-valent iron (ZVI)/H2O continuous processes using multivariate analysis and artificial neural networks
    Berardozzi, Eliana
    Donadelli, Jorge A.
    Teixeira, Antonio C. S. C.
    Guardani, Roberto
    Einschlag, Fernando S. Garcia
    CHEMICAL ENGINEERING JOURNAL, 2023, 453
  • [27] Methylene blue treatment with zero-valent iron/pyrite/H2O2 system under static and continuous flow conditions: Reaction mechanism and toxicity evaluation
    Oral, Ozlem
    Arslan, Sevki
    Dogan, Nazime Mercan
    Yildiz, Ilker
    Kantar, Cetin
    Abdelsalam, Amine Hafis
    Kuzucu, Volkan
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2024, 139 : 149 - 161
  • [28] Enhanced removal of Cr(VI) from aqueous solutions using a zero-valent nickel/iron-PDA@PVDF membrane prepared via a simple blending method
    Bi, Mingchun
    Liang, Yuning
    Chi, Weimeng
    Liu, Hongya
    Chen, Ying
    CHEMICAL ENGINEERING JOURNAL, 2024, 502
  • [29] Chromium(VI) removal from synthetic solution using novel zero-valent iron biochar composites derived from iron-rich sludge via one-pot synthesis
    Zhang, Qi
    Ye, Xuezhu
    Chen, De
    Xiao, Wendan
    Zhao, Shouping
    Li, Jun
    Li, Hui
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [30] Selective removal of nitroaromatic compounds from wastewater in an integrated zero valent iron (ZVI) reduction and ZVI/H2O2 oxidation process
    Liu, Jianguo
    Ou, Changjin
    Han, Weiqing
    Faheem
    Shen, Jinyou
    Bi, Huiping
    Sun, Xiuyun
    Li, Jiansheng
    Wang, Lianjun
    RSC ADVANCES, 2015, 5 (71) : 57444 - 57452