A novel screen-printed electrode modified with lead film for adsorptive stripping voltammetric determination of cobalt and nickel

被引:57
作者
Bobrowski, Andrzej [1 ]
Krolicka, Agnieszka [1 ]
Maczuga, Mariola [1 ]
Zarebski, Jerzy [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Bldg Mat Technol, PL-30059 Krakow, Poland
关键词
Adsorptive stripping voltammetry; Lead film screen printed electrode; Nickel; Cobalt; BISMUTH-FILM; ELECTROCHEMICAL CHARACTERIZATION; DIMETHYLGLYOXIME; SENSORS; NI(II); CO(II);
D O I
10.1016/j.snb.2013.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper presents the first report on the preparation of an in situ plated lead film screen-printed electrode (PbF-SPE) and its application for adsorptive stripping voltammetric determination of nickel and cobalt in the form of the complexes with dimethylglyoxime. The lead film was electrochemically deposited in situ on a commercially available three-electrode screen-printed electrochemical strip from a 0.2M ammonia buffer solution (pH 8.2) containing 4 x 10(-5) M Pb(NO3)(2) and 1 x 10(-5) M dimethylglyoxime. The composition of the supporting electrolyte and the influence of accumulation time on the stability of the lead coating and on the sensitivity and reproducibility of Ni and Co responses are discussed. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the lead film screen-printed electrode were equal to 4% and 3%, respectively (n = 10). The limits of detection established for simultaneous determination of Ni and Co for 90s of accumulation time were 0.2 and 0.3 mu g L-1, respectively. Voltammetric studies were complemented with optical and scanning microscopic observations. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 37 条
[1]   ASSESSMENT OF DIFFERENTIAL-PULSE ADSORPTION VOLTAMMETRY FOR THE SIMULTANEOUS DETERMINATION OF NICKEL AND COBALT IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :181-194
[2]  
[Anonymous], WHOSDEWSH050855
[3]   Electrochemical and spectroscopic investigation of the reduction of dimethylglyoxime at mercury electrodes in the presence of cobalt and nickel [J].
Baxter, LAM ;
Bobrowski, A ;
Bond, AM ;
Heath, GA ;
Paul, RL ;
Mrzljak, R ;
Zarebski, D .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :1312-1323
[4]  
Bobrowski A, 2000, ELECTROANAL, V12, P1177, DOI 10.1002/1521-4109(200010)12:15<1177::AID-ELAN1177>3.0.CO
[5]  
2-U
[6]   DETERMINATION OF COBALT BY ADSORPTIVE STRIPPING VOLTAMMETRY USING COBALT(II)-NIOXIME-NITRITE CATALYTIC-SYSTEM [J].
BOBROWSKI, A .
ANALYTICAL LETTERS, 1990, 23 (08) :1487-1503
[7]   Carbon paste electrode plated with lead film.: Voltammetric characteristics and application in adsorptive stripping voltammetry [J].
Bobrowski, Andrzej ;
Krolicka, Agnieszka ;
Lyczkowska, Ewa .
ELECTROANALYSIS, 2008, 20 (01) :61-67
[8]   Microscopic and electrochemical characterization of lead film electrode applied in adsorptive stripping analysis [J].
Bobrowski, Andrzej ;
Kalcher, Kurt ;
Kurowska, Katarzyna .
ELECTROCHIMICA ACTA, 2009, 54 (28) :7214-7221
[9]   ANALYTICAL DETERMINATION OF NICKEL IN THE ENVIRONMENT BY ADSORPTION VOLTAMMETRY USING THE MERCURY FILM ELECTRODE [J].
BRAUN, H ;
METZGER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 318 (05) :321-326
[10]   A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry [J].
Czop, Edyta ;
Economou, Anastasios ;
Bobrowski, Andrzej .
ELECTROCHIMICA ACTA, 2011, 56 (05) :2206-2212