Structures of MRI contrast agents in solution

被引:0
|
作者
Frullano, L
Rohovec, J
Peters, JA
Geraldes, CFGC
机构
[1] Delft Univ Technol, Lab Appl Organ Chem & Catalysis, NL-2628 BL Delft, Netherlands
[2] Charles Univ Prague, Dept Inorgan Chem, CZ-12840 Prague 2, Czech Republic
[3] Univ Coimbra, Fac Sci & Technol, Dept Biochem, P-3000 Coimbra, Portugal
[4] Univ Coimbra, Fac Sci & Technol, Ctr Neurosci, P-3000 Coimbra, Portugal
关键词
lanthanide chelates; chirality; conformations; molecular recognition; dynamics;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Contrast agents for magnetic resonance imaging are mainly Gd3+ complexes of octadentate polyaminopolycarboxylates and one water molecule in the first coordination sphere of the metal ion. Both the Ln(3+) ion and the nitrogen atoms in these complexes may be chiral. Therefore, various isomers may occur for these complexes, which interconvert in aqueous solution. Here studies on the configurations and conformations of Ln(3+) complexes of acyclic and cyclic ligands are reviewed. Furthermore, the structures of new generations of contrast agents that are able to target organs or to sense their biochemical environment are discussed. Molecular recognition is an important issue for these compounds.
引用
收藏
页码:25 / 60
页数:36
相关论文
共 50 条
  • [1] Macromolecular MRI contrast agents: Structures, properties and applications
    Tang, Jianbin
    Sheng, Yuqi
    Hu, Hongjie
    Shen, Youqing
    PROGRESS IN POLYMER SCIENCE, 2013, 38 (3-4) : 462 - 502
  • [2] Contrast agents for MRI
    Emily A. Waters
    Samuel A. Wickline
    Basic Research in Cardiology, 2008, 103 : 114 - 121
  • [3] Contrast agents for MRI
    Shokrollahi, H.
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4485 - 4497
  • [4] Contrast Agents in MRI
    Sobol, W. T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Contrast agents for MRI
    Waters, Emily A.
    Wickline, Samuel A.
    BASIC RESEARCH IN CARDIOLOGY, 2008, 103 (02) : 114 - 121
  • [6] MOLECULAR AND CRYSTAL-STRUCTURES OF 2 CHELATING-AGENTS FOR USE IN MRI CONTRAST AGENTS
    EHNEBOM, L
    PEDERSEN, BF
    KLAVENESS, J
    ACTA CHEMICA SCANDINAVICA, 1993, 47 (10): : 965 - 970
  • [7] OVERVIEW OF MRI CONTRAST AGENTS
    DUROUX, M
    RADIOLOGE, 1995, 35 (11): : S247 - S248
  • [8] METALLOPORPHYRIN CONTRAST AGENTS FOR MRI
    FIEL, RJ
    MAZURCHUK, R
    BUTTON, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 15 - INOR
  • [9] MRI Contrast Agents in Glycobiology
    Geraldes, Carlos F. G. C.
    Peters, Joop A.
    MOLECULES, 2022, 27 (23):
  • [10] Bioactivated MRI contrast agents
    McMurry, TJ
    Nivorozhkin, AL
    Kolodziej, AF
    Caravan, P
    Greenfield, MT
    Dunham, SU
    Dumas, SA
    Murr, MM
    Scott, DM
    Lauffer, RB
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2001, 86 (01) : 73 - 73