Power Controllability of Three-phase Converter with Unbalanced AC Source

被引:0
作者
Ma, Ke [1 ]
Liserre, Marco [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
来源
2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013) | 2013年
关键词
DC-AC converter; Unbalanced AC source; Control strategy; Fault tolerance; FAULT RIDE-THROUGH; CONTROL SCHEME; VOLTAGE; SYSTEMS; GENERATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three-phase DC-AC power converters suffer from power oscillation and overcurrent problems in case of unbalanced AC source voltage that can be caused by grid/generator faults. Existing solutions to handle these problems are properly selecting and controlling the positive and negative sequence currents. In this work a new series of control strategies which utilize the zero-sequence components are proposed to enhance the power control ability under this adverse condition. It is concluded that by introducing proper zero sequence current controls and corresponding circuit configurations, the power converter can enable more flexible control targets, achieving better performances in the delivered power and load current when suffering from unbalanced AC source.
引用
收藏
页码:342 / 350
页数:9
相关论文
共 29 条
[1]   Fault-Tolerant Torque Control of BLDC Motors [J].
Aghili, Farhad .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (02) :355-363
[2]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[3]   Overview of Recent Grid Codes for Wind Power Integration [J].
Altin, Muefit ;
Goeksu, Oemer ;
Teodorescu, Remus ;
Rodriguez, Pedro ;
Jensen, Birgitte-Bak ;
Helle, Lars .
OPTIM 2010: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, PTS I-IV, 2010, :1152-+
[4]  
[Anonymous], 5SYA204204 ABB
[5]   Three-phase four-wire shunt active filter control strategies [J].
Aredes, M ;
Hafner, J ;
Heumann, K .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) :311-318
[6]   NEW CONTROL ALGORITHMS FOR SERIES AND SHUNT 3-PHASE 4-WIRE ACTIVE POWER FILTERS [J].
AREDES, M ;
WATANABE, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1649-1656
[7]  
Blaabjerg F, 2012, PROC IEEE INT SYMP, P19, DOI 10.1109/ISIE.2012.6237053
[8]   Power Electronics Converters for Wind Turbine Systems [J].
Blaabjerg, Frede ;
Liserre, Marco ;
Ma, Ke .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (02) :708-719
[9]  
*E ON NETZ, 2006, HIGH EXTR HIGH VOLT
[10]   An Adaptive Control System for Three-Phase Photovoltaic Inverters Working in a Polluted and Variable Frequency Electric Grid [J].
Gonzalez-Espin, Fran ;
Garcera, Gabriel ;
Patrao, Ivan ;
Figueres, Emilio .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (10) :4248-4261