An integrated diabetic index using heart rate variability signal features for diagnosis of diabetes

被引:57
|
作者
Acharya, U. Rajendra [1 ]
Faust, Oliver [1 ]
Sree, S. Vinitha [2 ]
Ghista, Dhanjoo N. [3 ]
Dua, Sumeet [4 ]
Joseph, Paul [5 ]
Ahamed, V. I. Thajudin [6 ]
Janarthanan, Nittiagandhi [1 ]
Tamura, Toshiyo [7 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Commun Engn, Singapore 599489, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[3] Framingham State Coll, Framingham, MA 01701 USA
[4] Louisiana Tech Univ, Dept Comp Sci, Ruston, LA 71272 USA
[5] Natl Inst Technol, Dept Elect Engn, Calicut 673601, Kerala, India
[6] Govt Engn Coll, Dept Elect & Commun Engn, Wayanad 670644, Kerala, India
[7] Chiba Univ, Div Med Device & Technol, Chiba 263852, Japan
关键词
heart rate; diabetes; classifier; correlation dimension; recurrence plot; Poincare geometry; AUTONOMIC NEUROPATHY; SPECTRAL-ANALYSIS; RECURRENCE PLOTS; PREVALENCE; DYNAMICS; NEPHROPATHY; ALGORITHM; SYSTEMS; HUMANS;
D O I
10.1080/10255842.2011.616945
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Electrocardiogram (ECG) signals are difficult to interpret, and clinicians must undertake a long training process to learn to diagnose diabetes from subtle abnormalities in these signals. To facilitate these diagnoses, we have developed a technique based on the heart rate variability signal obtained from ECG signals. This technique uses digital signal processing methods and, therefore, automates the detection of diabetes from ECG signals. In this paper, we describe the signal processing techniques that extract features from heart rate (HR) signals and present an analysis procedure that uses these features to diagnose diabetes. Through statistical analysis, we have identified the correlation dimension, Poincare geometry properties (SD2), and recurrence plot properties (REC, DET, L mean) as useful features. These features differentiate the HR data of diabetic patients from those of patients who do not have the illness, and have been validated by using the AdaBoost classifier with the perceptron weak learner (yielding a classification accuracy of 86%). We then developed a novel diabetic integrated index (DII) that is a combination of these nonlinear features. The DII indicates whether a particular HR signal was taken from a person with diabetes. This index aids the automatic detection of diabetes, thereby allowing a more objective assessment and freeing medical professionals for other tasks.
引用
收藏
页码:222 / 234
页数:13
相关论文
共 50 条
  • [1] Automated Diagnosis of Diabetes Using Heart Rate Variability Signals
    Ahamed Seyd P.T.
    Paul K. Joseph
    Jeevamma Jacob
    Journal of Medical Systems, 2012, 36 : 1935 - 1941
  • [2] Automated Diagnosis of Diabetes Using Heart Rate Variability Signals
    Seyd, Ahamed P. T.
    Joseph, Paul K.
    Jacob, Jeevamma
    JOURNAL OF MEDICAL SYSTEMS, 2012, 36 (03) : 1935 - 1941
  • [3] POWER SPECTRUM ANALYSIS OF HEART-RATE-VARIABILITY SIGNAL IN THE DIAGNOSIS OF DIABETIC NEUROPATHY
    CERUTTI, S
    BIANCHI, A
    BONTEMPI, B
    COMI, G
    GIANOGLIO, P
    SORA, MGN
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 12 - 13
  • [4] Using Electrocardiogram Signal Features And Heart Rate Variability To Predict Epileptic Attacks
    Jiang, Ying
    Feng, Yuan
    Lu, Danni
    Yang, Lin
    Zhang, Qun
    Yang, Haiyan
    Li, Ning
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2025, 28 (08): : 1805 - 1815
  • [5] An Integrated Diabetic Retinopathy Index for the Diagnosis of Retinopathy Using Digital Fundus Image Features
    Krishnan, M. Muthu Rama
    Laude, Augustinus
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (02) : 306 - 313
  • [6] Heart rate variability analysis for diagnosis of diabetic peripheral neuropathy
    Morshed, Mohammad Golam
    Mukit, Mohammad Abdul
    Ahmed, Khawza Iftehar Uddin
    Mostafa, Raqibul
    Parveen, Sharmin
    Khandoker, Ahsan Habib
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1253 - 1256
  • [7] Fetal distress diagnosis using heart rate variability analysis: Design of a High Frequency Variability Index
    Logier, R.
    De jonckheere, J.
    Jeanne, M.
    Matis, R.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4728 - +
  • [8] Heart Rate Variability analysis using a Seismocardiogram signal
    Ramos-Castro, J.
    Moreno, J.
    Miranda-Vidal, H.
    Garcia-Gonzalez, M. A.
    Fernandez-Chimeno, Mireya
    Rodas, G.
    Capdevila, Ll.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5642 - 5645
  • [9] AUTOMATED DIAGNOSIS OF DIABETES USING ENTROPIES AND DIABETIC INDEX
    Acharya, U. Rajendra
    Fujita, Hamido
    Bhat, Shreya
    Koh, Joel Ew
    Adam, Muhammad
    Ghista, Dhanjoo N.
    Sudarshan, Vidya K.
    Poo, Chua Kok
    Chua, Chua Kuang
    Molinari, Filippo
    Ng, E. Y. K.
    San, Tan Ru
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (01)
  • [10] QUANTITATIVE-ANALYSIS OF HEART-RATE-VARIABILITY SIGNAL IN DIABETIC SUBJECTS
    CERUTTI, S
    BIANCHI, A
    BONTEMPI, B
    COMI, G
    GIANOGLIO, P
    LIBERATI, D
    MICOSSI, P
    SORA, MGN
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 145 - 146