Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction

被引:51
作者
Chen, Beibei [1 ]
Hu, Bin [1 ]
He, Man [1 ]
Huang, Qian [1 ]
Zhang, Yuan [1 ]
Zhang, Xing [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
基金
中国博士后科学基金;
关键词
PLASMA-MASS SPECTROMETRY; AMINO-ACIDS; BIOLOGICAL SAMPLES; ISOTOPE-DILUTION; SEPARATION; SELENOMETHIONINE; BIOAVAILABILITY; NANOPARTICLES; COLUMN;
D O I
10.1039/c2ja30280b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Elemental speciation in cells is significant for metallomics research. In this study, novel methods of (on-chip) magnetic solid phase extraction (MSPE) combined with high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) were proposed for selenium speciation in selenium-enriched yeast cells. An integrated microfluidic chip consisting of reaction, mixing, and extraction units was designed and fabricated for on-chip MSPE. Sulfonated polystyrene-coated magnetic nanoparticles (Fe3O4@PSS MNPs) were prepared as adsorption material for MSPE of selenoamino acids and selenopeptide. The factors affecting the extraction performance of the target selenium species by (on-chip) MSPE-HPLC-ICP-MS were systematically investigated. The analytical performance of the (on-chip) MSPE-HPLC-ICP-MS was evaluated under individual optimal conditions. The limits of detection for five target selenium species were 0.025 mu g L-1 to 0.090 mu g L-1 and 0.057 mu g L-1 to 0.149 mu g L-1 for MSPE-HPLC-ICP-MS and on-chip MSPE-HPLC-ICP-MS, respectively. The MSPE-HPLC-ICP-MS method is sensitive, fast, easy-to-operate, and economical. The on-chip MSPE-HPLC-ICP-MS method has the unique advantages of low sample consumption and high integration; thus, it is suitable for selenium speciation in a small number (similar to 800) of selenium-enriched yeast cells. A Certified Reference Material of SELM-1 yeast was used to validate the accuracy of the developed (on-chip) MSPE-HPLC-ICP-MS methods. The proposed methods were successfully applied to the speciation of selenium in selenium-enriched yeast cells. Analysis of approximately 800 cells by on-chip MSPE-HPLC-ICP-MS revealed that the average amounts of selenocystine (SeCys(2)) and selenomethionine (SeMet) in a single selenium-enriched yeast cell are in the order of subpicograms.
引用
收藏
页码:334 / 343
页数:10
相关论文
共 29 条
[11]   Separation and detection of Se-compounds by ion pairing liquid chromatography-microwave assisted hydride generation-atomic fluorescence spectrometry [J].
Dumont, E ;
De Cremer, K ;
Van Hulle, M ;
Chéry, CC ;
Vanhaecke, F ;
Cornelis, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :167-171
[12]  
Finley JW, 2006, NUTR REV, V64, P146, DOI [10.1301/nr.2006.mar.146-151, 10.1111/j.1753-4887.2006.tb00198.x]
[13]   Magnetic bead handling on-chip: new opportunities for analytical applications [J].
Gijs, MAM .
MICROFLUIDICS AND NANOFLUIDICS, 2004, 1 (01) :22-40
[14]   Metallomics as integrated biometal science [J].
Haraguchi, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :5-14
[15]   Silica-coated magnetic nanoparticles modified with γ-mercaptopropyltrimethoxysilane for fast and selective solid phase extraction of trace amounts of Cd, CuHg, and Pb in environmental and biological samples prior to their determination by inductively coupled plasma mass spectrometry [J].
Huang, Chaozhang ;
Hu, Bin .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (03) :437-444
[16]   Speciation of inorganic tellurium from seawater by ICP-MS following magnetic SPE separation and preconcentration [J].
Huang, Chaozhang ;
Hu, Bin .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (04) :760-767
[17]   Organic and inorganic selenium speciation in environmental and biological samples by nanometer-sized materials packed dual-column separation/preconcentration on-line coupled with ICP-MS [J].
Huang, Chaozhang ;
Hu, Bin ;
He, Man ;
Duan, Jiankun .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (03) :336-345
[18]   Selenium speciation analysis of selenium-enriched supplements by HPLC with ultrasonic nebulisation ICP-MS and electrospray MS/MS detection [J].
Infante, HG ;
O'Connor, G ;
Rayman, M ;
Wahlen, R ;
Entwisle, J ;
Norris, P ;
Hearn, R ;
Catterick, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1529-1538
[19]   Selenium speciation and bioavailability in biofortified products using species-unspecific isotope dilution and reverse phase ion paidng-inductively coupled plasma-mass spectrometry [J].
Kirby, J. K. ;
Lyons, G. H. ;
Karkkainen, M. P. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (05) :1772-1779
[20]   A micropillar-integrated smart microfluidic device for specific capture and sorting of cells [J].
Liu, Yan-Jun ;
Guo, Shi-Shang ;
Zhang, Zhi-Ling ;
Huang, Wei-Hua ;
Baigl, Damien ;
Xie, Min ;
Chen, Yong ;
Pang, Dai-Wen .
ELECTROPHORESIS, 2007, 28 (24) :4713-4722