Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction

被引:51
作者
Chen, Beibei [1 ]
Hu, Bin [1 ]
He, Man [1 ]
Huang, Qian [1 ]
Zhang, Yuan [1 ]
Zhang, Xing [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
基金
中国博士后科学基金;
关键词
PLASMA-MASS SPECTROMETRY; AMINO-ACIDS; BIOLOGICAL SAMPLES; ISOTOPE-DILUTION; SEPARATION; SELENOMETHIONINE; BIOAVAILABILITY; NANOPARTICLES; COLUMN;
D O I
10.1039/c2ja30280b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Elemental speciation in cells is significant for metallomics research. In this study, novel methods of (on-chip) magnetic solid phase extraction (MSPE) combined with high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) were proposed for selenium speciation in selenium-enriched yeast cells. An integrated microfluidic chip consisting of reaction, mixing, and extraction units was designed and fabricated for on-chip MSPE. Sulfonated polystyrene-coated magnetic nanoparticles (Fe3O4@PSS MNPs) were prepared as adsorption material for MSPE of selenoamino acids and selenopeptide. The factors affecting the extraction performance of the target selenium species by (on-chip) MSPE-HPLC-ICP-MS were systematically investigated. The analytical performance of the (on-chip) MSPE-HPLC-ICP-MS was evaluated under individual optimal conditions. The limits of detection for five target selenium species were 0.025 mu g L-1 to 0.090 mu g L-1 and 0.057 mu g L-1 to 0.149 mu g L-1 for MSPE-HPLC-ICP-MS and on-chip MSPE-HPLC-ICP-MS, respectively. The MSPE-HPLC-ICP-MS method is sensitive, fast, easy-to-operate, and economical. The on-chip MSPE-HPLC-ICP-MS method has the unique advantages of low sample consumption and high integration; thus, it is suitable for selenium speciation in a small number (similar to 800) of selenium-enriched yeast cells. A Certified Reference Material of SELM-1 yeast was used to validate the accuracy of the developed (on-chip) MSPE-HPLC-ICP-MS methods. The proposed methods were successfully applied to the speciation of selenium in selenium-enriched yeast cells. Analysis of approximately 800 cells by on-chip MSPE-HPLC-ICP-MS revealed that the average amounts of selenocystine (SeCys(2)) and selenomethionine (SeMet) in a single selenium-enriched yeast cell are in the order of subpicograms.
引用
收藏
页码:334 / 343
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 2012, Molecular Cloning: A Laboratory Manual
[2]   Selenium speciation analysis using inductively coupled plasma-mass spectrometry [J].
B'Hymer, C ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :1-20
[3]   Magnetic ion-exchange nanoparticles and their application in proton exchange membranes [J].
Brijmohan, Smita B. ;
Shaw, Montgomery T. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 303 (1-2) :64-71
[4]   Nanoparticle labelling-based magnetic immunoassay on chip combined with electrothermal vaporization - inductively coupled plasma mass spectrometry for the determination of carcinoembryonic antigen in human serum [J].
Chen, Beibei ;
Hu, Bin ;
Jiang, Ping ;
He, Man ;
Peng, Hanyong ;
Zhang, Xing .
ANALYST, 2011, 136 (19) :3934-3942
[5]   Ionic liquids improved reversed-phase HPLC on-line coupled with ICP-MS for selenium speciation [J].
Chen, Beibei ;
He, Man ;
Mao, Xiangju ;
Cui, Ran ;
Pang, Daiwen ;
Hu, Bin .
TALANTA, 2011, 83 (03) :724-731
[6]   Magnetic solid phase microextraction on a microchip combined with electrothermal vaporization-inductively coupled plasma mass spectrometry for determination of Cd, Hg and Pb in cells [J].
Chen, Beibei ;
Heng, Shujing ;
Peng, Hanyong ;
Hu, Bin ;
Yu, Xu ;
Zhang, Zhiling ;
Pang, Daiwen ;
Yue, Xin ;
Zhu, Ying .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (12) :1931-1938
[7]   Adsorptions of heavy metal ions by a magnetic chelating resin containing hydroxy and iminodiacetate groups [J].
Chen, Chuh-Yean ;
Chiang, Chen-Li ;
Huang, Po-Chen .
SEPARATION AND PURIFICATION TECHNOLOGY, 2006, 50 (01) :15-21
[8]   Evaluation of porous graphitic carbon stationary phase for simultaneous preconcentration and separation of organic and inorganic selenium species in "clean" water systems [J].
Dauthieu, M ;
Bueno, M ;
Darrouzes, K ;
Gilon, N ;
Potin-Gautier, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :34-39
[9]   Speciation of selenomethionine and selenocystine using online micro-column containing Cu(II) loaded nanometer-sized Al2O3 coupled with ICP-MS detection [J].
Duan, Jiankun ;
Hu, Bin .
TALANTA, 2009, 79 (03) :734-738
[10]   Separation and determination of seleno amino acids using gas chromatography hyphenated with inductively coupled plasma mass spectrometry after hollow fiber liquid phase microextractiion [J].
Duan, Jiankun ;
Hu, Bin .
JOURNAL OF MASS SPECTROMETRY, 2009, 44 (05) :605-612