Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy

被引:24
作者
Palmer, Antony [1 ,2 ]
Hayman, Orla [1 ]
Muscat, Sarah [1 ]
机构
[1] Portsmouth Hosp NHS Trust, Queen Alexandra Hosp, Dept Med Phys, Portsmouth PO6 3LY, Hants, England
[2] Univ Surrey, Fac Engn & Phys Sci, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
high dose-rate (HDR); brachytherapy; cervix cancer; Co-60; treatment plan; TECHNICAL NOTE; RECOMMENDATIONS; DISTRIBUTIONS;
D O I
10.5114/jcb.2012.27952
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate whether Co-60 is equivalent to Ir-192 for HDR cervical brachytherapy, through 3D-DVH dose comparisons in standard and optimised plans. Previous studies have only considered 2D dosimetry, point dose comparisons or identical loading. Typical treatment times and economics are considered. Material and methods: Plans were produced for eight cervix patients using Co-60 and Ir-192 sources, CT imaging and IU/two-channel-ring applicator (Eckert Ziegler BEBIG). The comparison was made under two conditions: (A) identical dwell positions and loading, prescribed to Point A and (B) optimised source dwells, prescribed to HR-CTV. This provided a direct comparison of inherent differences and residual differences under typical clinical plan optimisation. The DVH (target and OAR), ICRU reference points and isodose distributions were compared. Typical treatment times and source replacement costs were compared. Results: Small differences (p < 0.01) in 3D dosimetry exist when using Co-60 compared to Ir-192, prescribed to Point A with identical loading patterns, particularly 3.3% increase in rectum D2cc. No significant difference was observed in this parameter when prescribing to the HR-CTV using dwell-time optimisation. There was no statistically significant difference in D90 between the two isotopes. Co-60 plans delivered consistently higher V150% (mean +4.4%, p = 0.03) and V400% (mean +11.6%, p < 0.01) compared to Ir-192 in optimised plans. Differences in physical source properties were overwhelmed by geometric effects. Conclusions: Co-60 may be used as an effective alternative to Ir-192 for HDR cervix brachytherapy, producing similar plans of equivalent D90, but with logistical benefits. There is a small dose increase along the extension of the source axis when using Co-60 compared to Ir-192, leading to small rectal dose increases for identical loading patterns. This can be eliminated by planning optimisation techniques. Such optimisation may also be associated with increases in the overdose volume (V150-V400) with Co-60 compared to Ir-192.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2011, J CONTEMP BRACHYTHER
[2]  
Chassagne D, 1985, ICRU report no. 38: Dose and volume specification for reporting intracavitary therapy in gynecology
[4]   Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources [J].
Granero, D. ;
Perez-Calatayud, J. ;
Ballester, F. .
MEDICAL PHYSICS, 2008, 35 (04) :1280-1287
[5]   Technical note:: Dosimetric study of a. new Co-60 source used in brachytherapy [J].
Granero, D. ;
Perez-Calatayud, J. ;
Ballester, F. .
MEDICAL PHYSICS, 2007, 34 (09) :3485-3488
[6]   REMOTE AFTERLOADING WITH INTRACAVITARY APPLICATORS [J].
HENSCHKE, UK ;
HILARIS, BS ;
MAHAN, GD .
RADIOLOGY, 1964, 83 (02) :344-345
[7]   High-dose rate brachytherapy in the treatment of carcinoma of uterine cervix: twenty-year experience with cobalt after-loading system [J].
Mosalaei, A ;
Mohammadianpanah, M ;
Omidvari, S ;
Ahmadloo, N .
INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2006, 16 (03) :1101-1105
[8]   The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for carcinoma of the cervix [J].
Nag, S ;
Erickson, B ;
Thomadsen, E ;
Orton, C ;
Demanes, JD ;
Petereit, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :201-211
[9]  
Ntekim A, 2010, CLIN MED INSIGHTS-ON, V4, P89
[10]   A comparison of dose distributions of HDR intracavitary brachytherapy using different sources and treatment planning systems [J].
Park, Dong-Wook ;
Kim, Young Seok ;
Park, Sung Ho ;
Choi, Eun Kyung ;
Do Ahn, Seung ;
Lee, Sang-Wook ;
Song, Si Yeol ;
Kim, Jong Hoon .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) :1426-1431