A novel extraction and preconcentration of ultra-trace levels of uranium ions in natural water samples using functionalized magnetic-nanoparticles prior to their determination by inductively coupled plasma-optical emission spectrometry

被引:40
作者
Rezaei, Ali [1 ]
Khani, Hadi [2 ]
Masteri-Farahani, Majid [1 ]
Rofouei, Mohammad Kazem [1 ]
机构
[1] Tarbiat Moallem Univ, Fac Chem, Tehran, Iran
[2] ACECR, Iranian Res & Dev Ctr Chem Ind, Tehran, Iran
关键词
SOLID-PHASE EXTRACTION; HEAVY-METAL IONS; SPECTROPHOTOMETRIC DETERMINATION; ENVIRONMENTAL-SAMPLES; SILICA-GEL; SEPARATION; THORIUM(IV); REMOVAL; ACID; ADSORPTION;
D O I
10.1039/c2ay25664a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New modified magnetic nanoparticles functionalized with salicylaldehyde groups were designed and synthesized to produce a Schiff base-sorbent for extraction/preconcentration of sub-ppb levels of uranium ions in water samples prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). In the separation process, an aqueous solution of U(VI) ions was mixed with 100 mg of functionalized Fe3O4 magnetic nanoparticles with salicylaldehyde groups (Sal-APS-FMNPs) and then an external magnetic field was applied for isolation of Sal-APS-FMNPs containing uranium ions. Experimental conditions for an effective adsorption including pH, sample volume, eluent concentration, and presence of co-existing ions have been studied and established. Under the optimal extraction and preconcentration conditions, a limit of detection (LOD) of 0.24 ng mL(-1) and a relative standard deviation (RSD) of 1.5% (n = 8) were achieved by ICP-OES. The analytical curve was linear in the range 1-5000 ng mL(-1). Under the optimum conditions, the sorption capacity of Sal-APS-FMNPs has been found to be 49 mg of U(VI) ions per gram at pH 7 with a preconcentration factor of 1000 (1 mL of elution for a 1000 mL sample volume). The proposed method is characterized with high enrichment factor, easy preparation and regeneration of sorbent, short time of sample pretreatment, fast and really clean separation, high extraction yields, wide linear curve, and low detection limits. Finally, the proposed method was successfully used for extraction, preconcentration, and determination of U(VI) ions in some real samples.
引用
收藏
页码:4107 / 4114
页数:8
相关论文
共 50 条
[31]   Highly selective preconcentration of ultra-trace amounts of lead ions in real water and food samples by dispersive solid phase extraction using modified magnetic graphene oxide as a novel sorbent [J].
Akbarzade, S. ;
Chamsaz, M. ;
Rounaghi, G. H. .
ANALYTICAL METHODS, 2018, 10 (18) :2081-2087
[32]   Ligandless-ultrasound-assisted emulsification microextraction followed by inductively coupled plasma-optical emission spectrometry for simultaneous determination of heavy metals in water samples [J].
Karimi, Maryam ;
Sereshti, Hassan ;
Khojeh, Vahid ;
Samadi, Soheila .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (04) :401-415
[33]   Extraction of trace amounts of mercury with sodium dodecyle sulphate-coated magnetite nanoparticles and its determination by flow injection inductively coupled plasma-optical emission spectrometry [J].
Faraji, Mohammad ;
Yamini, Yadollah ;
Rezaee, Mohammad .
TALANTA, 2010, 81 (03) :831-836
[34]   Time-based on-line preconcentration cold vapour generation procedure for ultra-trace mercury determination - with inductively coupled plasma atomic emission spectrometry [J].
Anthemidis, AN ;
Zachariadis, GA ;
Michos, CE ;
Stratis, JA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (5-6) :764-769
[35]   Time-based on-line preconcentration cold vapour generation procedure for ultra-trace mercury determination with inductively coupled plasma atomic emission spectrometry [J].
Aristidis N. Anthemidis ;
George A. Zachariadis ;
Christos E. Michos ;
John A. Stratis .
Analytical and Bioanalytical Chemistry, 2004, 379 :764-769
[36]   Ferrofluid-Based Preconcentration and Ultra-Trace Determination of Pt, Pd, Au, and Ag in Complex Matrices Using Inductively Coupled Plasma Mass Spectrometry [J].
Gotame, Yam Nath ;
Gandolfi, Vivien ;
Beauchemin, Diane .
ATOMIC SPECTROSCOPY, 2022, 43 (06) :443-449
[37]   A nanoparticle-based solid-phase extraction procedure followed by flow injection inductively coupled plasma-optical emission spectrometry to determine some heavy metal ions in water samples [J].
Faraji, Mohammad ;
Yamini, Yadollah ;
Saleh, Abolfazl ;
Rezaee, Mohammad ;
Ghambarian, Mahnaz ;
Hassani, Rahim .
ANALYTICA CHIMICA ACTA, 2010, 659 (1-2) :172-177
[38]   Cloud point extraction combined with flow injection vapor generation inductively coupled plasma mass spectrometry for preconcentration and determination of ultra trace Cd, Sb and Hg in water samples [J].
Liao, Pei-Han ;
Jiang, Shiuh-Jen ;
Sahayam, A. C. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (09) :1518-1524
[39]   Determination of cadmium in water and environmental samples by inductively coupled plasma atomic emission spectrometry after solid phase extraction using thiosemicarbazide derivative on alumina [J].
Sabermahani, F. ;
Askari, R. ;
Hosseinifard, S. J. ;
Saeidi, M. .
SCIENTIA IRANICA, 2014, 21 (06) :2012-2020
[40]   Silica-coated magnetic graphene oxide nanocomposite based magnetic solid phase extraction of trace amounts of heavy metals in water samples prior to determination by inductively coupled plasma mass spectrometry [J].
Suo, Lingzhe ;
Dong, Xinyi ;
Gao, Xun ;
Xu, Jianfeng ;
Huang, Zhen ;
Ye, Jing ;
Lu, Xiumei ;
Zhao, Longshan .
MICROCHEMICAL JOURNAL, 2019, 149