Reproducibility of ECG-gated Ultrasound Diameter Assessment of Small Abdominal Aortic Aneurysms

被引:35
作者
Bredahl, K. [1 ]
Eldrup, N. [2 ]
Meyer, C. [3 ]
Eiberg, J. E. [1 ]
Sillesen, H. [1 ]
机构
[1] Univ Copenhagen Hosp, Dept Intervent Radiol, DK-2100 Copenhagen, Denmark
[2] Aarhus Univ Hosp, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Cardoz, Copenhagen, Denmark
关键词
Aortic aneurysm; Abdominal; Ultrasonography; Imaging; Observer variation; Electrocardiogram; RANDOMIZED CONTROLLED-TRIAL; VARIABILITY; MORTALITY; SURGERY; SURVEILLANCE;
D O I
10.1016/j.ejvs.2012.12.010
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation. Design: Prospective cornparative study. Methods: Consecutive patients (N = 27) with an AAA, attending their 6-month control as part of a medical treatment trial, were scanned twice by two ultrasound operators. Then, all ultrasound recordings were transferred to a core facility and analysed by a third person. The AAA diameter was determined in four different ways: from the leading edge of adventitia on the anterior wall to either the leading edge of the adventitia (method A) or leading edge of the intima (method B) on the posterior wall, with both measurements performed in systole and diastole. Result: Inter-operator reproducibility was +/- 3 mm for all methods applied. There was no difference in outcome between methods A and B; likewise, end-diastolic measurement did not improve reproducibility in preference to peak-systolic measurement. Conclusion: The use of a standardised ultrasound protocol including ECG-gating and subsequent off-line reading with minute calliper placement reduces variability. This may be of use in developing protocols to better detect even small AAA growth rates during clinical trials. (C) 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 16 条
  • [1] ACCURACY OF ULTRASONOGRAPHIC MEASUREMENT OF INFRARENAL ABDOMINAL AORTIC-ANEURYSM
    AKKERSDIJK, GJM
    PUYLAERT, JBCM
    COERKAMP, EG
    DEVRIES, AC
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (03) : 376 - 376
  • [2] Reproducibility of ultrasound measurement of the abdominal aorta
    Beales, L.
    Wolstenhulme, S.
    Evans, J. A.
    West, R.
    Scott, D. J. A.
    [J]. BRITISH JOURNAL OF SURGERY, 2011, 98 (11) : 1517 - 1525
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] The Cardiac Cycle is a Major Contributor to Variability in Size Measurements of Abdominal Aortic Aneurysms by Ultrasound
    Grondal, N.
    Bramsen, M. B.
    Thomsen, M. D.
    Rasmussen, C. B.
    Lindholt, J. S.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (01) : 30 - 33
  • [5] Ultrasound Measurement of Aortic Diameter in a National Screening Programme
    Hartshorne, T. C.
    McCollum, C. N.
    Earnshaw, J. J.
    Morris, J.
    Nasim, A.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (02) : 195 - 199
  • [6] RUPTURED ABDOMINAL AORTIC-ANEURYSMS - A STUDY OF INCIDENCE AND MORTALITY
    JOHANSSON, G
    SWEDENBORG, J
    [J]. BRITISH JOURNAL OF SURGERY, 1986, 73 (02) : 101 - 103
  • [7] Mortality in ruptured abdominal aortic aneurysms
    Kantonen, I
    Lepäntalo, M
    Brommels, M
    Luther, M
    Salenius, JP
    Ylönen, K
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (03) : 208 - 212
  • [8] VARIABILITY IN MEASUREMENT OF ABDOMINAL AORTIC-ANEURYSMS
    LEDERLE, FA
    WILSON, SE
    JOHNSON, GR
    REINKE, DB
    LITTOOY, FN
    ACHER, CW
    MESSINA, LM
    BALLARD, DJ
    ANSEL, HJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) : 945 - 952
  • [9] Screening for abdominal aortic aneurysms: single centre randomised controlled trial
    Lindholt, JS
    Juul, S
    Fasting, H
    Henneberg, EW
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2005, 330 (7494): : 750 - 752B
  • [10] Measuring the Maximum Diameter of Native Abdominal Aortic Aneurysms: Review and Critical Analysis
    Long, A.
    Rouet, L.
    Lindholt, J. S.
    Allaire, E.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (05) : 515 - 524