Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System

被引:5
作者
Mueller, Kerstin [1 ]
Fahrig, Rebecca [1 ]
Manhart, Michael [2 ]
Deuerling-Zheng, Yu [2 ]
Rosenberg, Jarrett [1 ]
Moore, Teri [3 ]
Ganguly, Arundhuti [1 ]
Kothary, Nishita [1 ,4 ]
机构
[1] Stanford Univ, Dept Radiol, 1201 Welch Rd, Stanford, CA 94305 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut Inc, Malvern, PA USA
[4] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
Parenchymal blood volume (PBV); CBCT; porcine study; chemoembolization; FLAT-DETECTOR CT; TRANSARTERIAL CHEMOEMBOLIZATION; HEPATOCELLULAR-CARCINOMA; COMPUTED-TOMOGRAPHY; LIVER-DISEASE; PERFUSION; TUMOR; SUITE; INTERVENTIONS; SOFTWARE;
D O I
10.1016/j.acra.2016.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Intra-procedural measurement of hepatic perfusion following liver embolization continues to be a challenge. Blood volume imaging before and after interventional procedures would allow identifying the treatment end point or even allow predicting treatment outcome. Recent liver oncology studies showed the feasibility of parenchymal blood volume (PBV) imaging using an angiographic C-arm system. This study was done to evaluate the reproducibility of PBV measurements using cone beam computed tomography (CBCT) before and after embolization of the liver in a swine model. Materials and,Methods: CBCT imaging was performed before and after partial bland embolization of the left lobe of the liver in five adult pigs. Intra-arterial injection of iodinated contrast with a 6-second x-ray delay was used with a two-sweep 8-second rotation imaging protocol. Three acquisitions, each separated by 10 minutes to allow for contrast clearance, were obtained before and after embolization in each animal. Post-processing was carried out using dedicated software to generate three-dimensional (3D) PBV maps. Two region of-interest measurements were placed on two views within the right and left lobe on each CBCT 3D PBV map. Variation in PBV for scans acquired within each animal was determined by the coefficient of variation and intraclass correlation. A Wilcoxon signed-rank test was used to test post-procedure reduction in PBV. Results: The CBCT PBV maps showed mean coefficients of variation of 7% (range: 2%-16%) and 25% (range: 13%-34%) for baseline and embolized PBV maps, respectively. The intraclass correlation for PBV measurements was 0.89, demonstrating high reproducibility, with measurable reduction in PBV displayed after embolization (P = 0.007). Conclusions: Intra-procedural acquisition of 3D PBV maps before and after liver embolization using CBCT is highly reproducible and shows promising application for obtaining intra-procedural PBV maps during locoregional therapy.
引用
收藏
页码:1441 / 1445
页数:5
相关论文
共 50 条
  • [41] A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance
    Hua, Chiaho
    Yao, Weiguang
    Kidani, Takao
    Tomida, Kazuo
    Ozawa, Saori
    Nishimura, Takenori
    Fujisawa, Tatsuya
    Shinagawa, Ryousuke
    Merchant, Thomas E.
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1079)
  • [42] C-arm Lipiodol CT in transcatheter arterial chemoembolization for small hepatocellular carcinoma
    Jian-Jun Li
    Jia-Sheng Zheng
    Shi-Chang Cui
    Xiong-Wei Cui
    Cai-Xia Hu
    Da Fang
    Lin-Chao Ye
    World Journal of Gastroenterology, 2015, (10) : 3035 - 3040
  • [43] C-arm Lipiodol CT in transcatheter arterial chemoembolization for small hepatocellular carcinoma
    Li, Jian-Jun
    Zheng, Jia-Sheng
    Cui, Shi-Chang
    Cui, Xiong-Wei
    Hu, Cai-Xia
    Fang, Da
    Ye, Lin-Chao
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (10) : 3035 - 3040
  • [44] C-arm CT for chemo-embolization of liver tumors
    Huppert, P. E.
    Firlbeck, G.
    Meissner, O. A.
    Wietholtz, H.
    RADIOLOGE, 2009, 49 (09): : 830 - 836
  • [45] C-arm CT for chemo-embolization of liver tumors
    Huppert, P. E.
    Firlbeck, G.
    Meissner, O. A.
    Wietholtz, H.
    RADIOLOGE, 2009, 49 (09): : 830 - 836
  • [46] Cardiac C-arm CT:: Image-based gating
    Rohkohl, C.
    Pruemmer, A.
    Fahrig, R.
    Lauritsch, G.
    Hornegger, J.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [47] A Novel Temporal Recovery Technique to Enable Cone Beam CT Perfusion Imaging Using an Interventional C-Arm System
    Tang, Jie
    Xu, Min
    Niu, Kai
    Royalty, Kevin
    Pulfer, Kari
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [48] Parenchymal Liver Blood Volume and Dynamic Volume Perfusion CT Measurements of Hepatocellular Carcinoma in Patients Undergoing Transarterial Chemoembolization
    Rathmann, Nils
    Kara, Kerim
    Budjan, Johannes
    Henzler, Thomas
    Smakic, Arman
    Schoenberg, Stefan O.
    Diehl, Steffen J.
    ANTICANCER RESEARCH, 2017, 37 (10) : 5681 - 5685
  • [49] Right Adrenal Venography Findings correlated with C-arm CT for Selection During C-arm CT-assisted Adrenal Vein Sampling in Primary Aldosteronism
    Park, Sung Il
    Rhee, Yumie
    Lim, Jung Soo
    Park, Sungha
    Kang, Sang Wook
    Lee, Mu Sook
    Lee, Myungsu
    Lee, Shin Jae
    Kim, Il Jung
    Lee, Do Yun
    Cho, June-Sik
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (06) : 1469 - 1475
  • [50] The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms
    Chintalapani, G.
    Chinnadurai, P.
    Maier, A.
    Xia, Y.
    Bauer, S.
    Shaltoni, H.
    Morsi, H.
    Mawad, M. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 660 - 666