Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System

被引:5
作者
Mueller, Kerstin [1 ]
Fahrig, Rebecca [1 ]
Manhart, Michael [2 ]
Deuerling-Zheng, Yu [2 ]
Rosenberg, Jarrett [1 ]
Moore, Teri [3 ]
Ganguly, Arundhuti [1 ]
Kothary, Nishita [1 ,4 ]
机构
[1] Stanford Univ, Dept Radiol, 1201 Welch Rd, Stanford, CA 94305 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut Inc, Malvern, PA USA
[4] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
Parenchymal blood volume (PBV); CBCT; porcine study; chemoembolization; FLAT-DETECTOR CT; TRANSARTERIAL CHEMOEMBOLIZATION; HEPATOCELLULAR-CARCINOMA; COMPUTED-TOMOGRAPHY; LIVER-DISEASE; PERFUSION; TUMOR; SUITE; INTERVENTIONS; SOFTWARE;
D O I
10.1016/j.acra.2016.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Intra-procedural measurement of hepatic perfusion following liver embolization continues to be a challenge. Blood volume imaging before and after interventional procedures would allow identifying the treatment end point or even allow predicting treatment outcome. Recent liver oncology studies showed the feasibility of parenchymal blood volume (PBV) imaging using an angiographic C-arm system. This study was done to evaluate the reproducibility of PBV measurements using cone beam computed tomography (CBCT) before and after embolization of the liver in a swine model. Materials and,Methods: CBCT imaging was performed before and after partial bland embolization of the left lobe of the liver in five adult pigs. Intra-arterial injection of iodinated contrast with a 6-second x-ray delay was used with a two-sweep 8-second rotation imaging protocol. Three acquisitions, each separated by 10 minutes to allow for contrast clearance, were obtained before and after embolization in each animal. Post-processing was carried out using dedicated software to generate three-dimensional (3D) PBV maps. Two region of-interest measurements were placed on two views within the right and left lobe on each CBCT 3D PBV map. Variation in PBV for scans acquired within each animal was determined by the coefficient of variation and intraclass correlation. A Wilcoxon signed-rank test was used to test post-procedure reduction in PBV. Results: The CBCT PBV maps showed mean coefficients of variation of 7% (range: 2%-16%) and 25% (range: 13%-34%) for baseline and embolized PBV maps, respectively. The intraclass correlation for PBV measurements was 0.89, demonstrating high reproducibility, with measurable reduction in PBV displayed after embolization (P = 0.007). Conclusions: Intra-procedural acquisition of 3D PBV maps before and after liver embolization using CBCT is highly reproducible and shows promising application for obtaining intra-procedural PBV maps during locoregional therapy.
引用
收藏
页码:1441 / 1445
页数:5
相关论文
共 50 条
  • [31] C-arm CT for planning and guidance of extrahepatic embolizations
    Wacker, F. K.
    Meissner, O. A.
    Meyer, B. C.
    RADIOLOGE, 2009, 49 (09): : 842 - 847
  • [32] Performance evaluation of a C-Arm CT perfusion phantom
    Boese, Axel
    Gugel, Sebastian
    Serowy, Steffen
    Purmann, Jonas
    Rose, Georg
    Beuing, Oliver
    Skalej, Martin
    Kyriakou, Yiannis
    Yu Deuerling-Zheng
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (05) : 799 - 807
  • [33] Parenchymal hyperdensity on C-arm CT images after endovascular therapy for acute ischaemic stroke predicts a poor prognosis
    Chen, W-H
    Yi, T-Y
    Wu, Y-M
    Zhang, M-F
    Lin, D-L
    Lin, X-H
    CLINICAL RADIOLOGY, 2019, 74 (05) : 399 - 404
  • [34] Performance evaluation of a C-Arm CT perfusion phantom
    Axel Boese
    Sebastian Gugel
    Steffen Serowy
    Jonas Purmann
    Georg Rose
    Oliver Beuing
    Martin Skalej
    Yiannis Kyriakou
    Yu Deuerling-Zheng
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 799 - 807
  • [35] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [36] Closed Sinusoid Trajectory for C-Arm CT Imaging
    Yang, Haiquan
    Li, Meihua
    Koizumi, Kazuhito
    Kudo, Hiroyuki
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3480 - 3484
  • [37] C-arm CT for planning and guidance of extrahepatic embolizations
    Wacker, F. K.
    Meissner, O. A.
    Meyer, B. C.
    RADIOLOGE, 2009, 49 (09): : 842 - 847
  • [38] Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement
    van den Hoven, Andor F.
    Prince, Jip F.
    de Keizer, Bart
    Vonken, Evert-Jan P. A.
    Bruijnen, Rutger C. G.
    Verkooijen, Helena M.
    Lam, Marnix G. E. H.
    van den Bosch, Maurice A. A. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (01) : 64 - 73
  • [39] Spatially regularized region-based perfusion estimation in peripherals using angiographic C-arm systems
    Giordano, M.
    Vonken, E. P. A.
    Bertram, M.
    Mali, W. P. T. M.
    Viergever, M. A.
    Neukirchen, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) : 7239 - 7259
  • [40] Analyzed outcome for embolization of hepatic carcinoma by C-arm angiographic computed tomography
    Kuo, Jen-Chen
    Lu, Nan-Han
    Huang, Yung-Hui
    Hshiao, Ming-Hong
    Lin, Yao-Nan
    Lee, Chen-Chang
    Chao, Shih-Yu
    Chen, Tai-Been
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (05) : 645 - 651