Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System

被引:5
作者
Mueller, Kerstin [1 ]
Fahrig, Rebecca [1 ]
Manhart, Michael [2 ]
Deuerling-Zheng, Yu [2 ]
Rosenberg, Jarrett [1 ]
Moore, Teri [3 ]
Ganguly, Arundhuti [1 ]
Kothary, Nishita [1 ,4 ]
机构
[1] Stanford Univ, Dept Radiol, 1201 Welch Rd, Stanford, CA 94305 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Siemens Med Solut Inc, Malvern, PA USA
[4] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
Parenchymal blood volume (PBV); CBCT; porcine study; chemoembolization; FLAT-DETECTOR CT; TRANSARTERIAL CHEMOEMBOLIZATION; HEPATOCELLULAR-CARCINOMA; COMPUTED-TOMOGRAPHY; LIVER-DISEASE; PERFUSION; TUMOR; SUITE; INTERVENTIONS; SOFTWARE;
D O I
10.1016/j.acra.2016.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Intra-procedural measurement of hepatic perfusion following liver embolization continues to be a challenge. Blood volume imaging before and after interventional procedures would allow identifying the treatment end point or even allow predicting treatment outcome. Recent liver oncology studies showed the feasibility of parenchymal blood volume (PBV) imaging using an angiographic C-arm system. This study was done to evaluate the reproducibility of PBV measurements using cone beam computed tomography (CBCT) before and after embolization of the liver in a swine model. Materials and,Methods: CBCT imaging was performed before and after partial bland embolization of the left lobe of the liver in five adult pigs. Intra-arterial injection of iodinated contrast with a 6-second x-ray delay was used with a two-sweep 8-second rotation imaging protocol. Three acquisitions, each separated by 10 minutes to allow for contrast clearance, were obtained before and after embolization in each animal. Post-processing was carried out using dedicated software to generate three-dimensional (3D) PBV maps. Two region of-interest measurements were placed on two views within the right and left lobe on each CBCT 3D PBV map. Variation in PBV for scans acquired within each animal was determined by the coefficient of variation and intraclass correlation. A Wilcoxon signed-rank test was used to test post-procedure reduction in PBV. Results: The CBCT PBV maps showed mean coefficients of variation of 7% (range: 2%-16%) and 25% (range: 13%-34%) for baseline and embolized PBV maps, respectively. The intraclass correlation for PBV measurements was 0.89, demonstrating high reproducibility, with measurable reduction in PBV displayed after embolization (P = 0.007). Conclusions: Intra-procedural acquisition of 3D PBV maps before and after liver embolization using CBCT is highly reproducible and shows promising application for obtaining intra-procedural PBV maps during locoregional therapy.
引用
收藏
页码:1441 / 1445
页数:5
相关论文
共 50 条
  • [21] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Phan, Catherine M.
    Macklin, Eric A.
    Bredella, Miriam A.
    Dadrich, Monica
    Flechsig, Paul
    Yoo, Albert J.
    Hirsch, Joshua A.
    Gupta, Rajiv
    SKELETAL RADIOLOGY, 2011, 40 (08) : 1065 - 1072
  • [22] C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
    Niu, K.
    Yang, P.
    Wu, Y.
    Struffert, T.
    Doerfler, A.
    Schafer, S.
    Royalty, K.
    Strother, C.
    Chen, G. -H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (07) : 1303 - 1309
  • [23] Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)
    Vogl, Thomas J.
    Schaefer, Patrik
    Lehnert, Thomas
    Nour-Eldin, A.
    Ackermann, Hanns
    Mbalisike, Emmanuel
    Hammerstingl, Renate
    Eichler, Katrin
    Zangos, Stephan
    Naguib, Nagy N. N.
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 755 - 763
  • [24] Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)
    Thomas J. Vogl
    Patrik Schaefer
    Thomas Lehnert
    Nour-Eldin A. Nour-Eldin
    Hanns Ackermann
    Emmanuel Mbalisike
    Renate Hammerstingl
    Katrin Eichler
    Stephan Zangos
    Nagy N. N. Naguib
    European Radiology, 2016, 26 : 755 - 763
  • [25] Digital volume tomography. Dedicated scanner and cone beam CT with C-arm systems
    Fiebich, M.
    Weber, D.
    RADIOLOGE, 2018, 58 (03): : 194 - 201
  • [26] Scatter correction using a primary modulator on a clinical angiography C-arm CT system
    Bier, Bastian
    Berger, Martin
    Maier, Andreas
    Kachelriess, Marc
    Ritschl, Ludwig
    Mueller, Kerstin
    Choi, Jang-Hwan
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2017, 44 (09) : E125 - E137
  • [27] Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT
    Xia, Y.
    Bauer, S.
    Maier, A.
    Berger, M.
    Hornegger, J.
    MEDICAL PHYSICS, 2015, 42 (04) : 1787 - 1796
  • [28] Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology
    Tanaka, T.
    Arai, Y.
    Inaba, Y.
    Inoue, M.
    Nishiofuku, H.
    Anai, H.
    Hori, S.
    Sakaguchi, H.
    Kichikawa, K.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
  • [29] Assessment of a photon-counting detector for a dual-energy C-arm angiographic system
    Ahmad, Moiz
    Fahrig, Rebecca
    Pung, Leland
    Spahn, Martin
    Koester, Niko S.
    Reitz, Silke
    Moore, Teri
    Choi, Jang-Hwan
    Hinshaw, Waldo
    Xia, Yan
    Mueller, Kerstin
    MEDICAL PHYSICS, 2017, 44 (11) : 5938 - 5948
  • [30] Voxel-Based Mapping of C-arm CT Cerebral Blood Volume to Infarct Probability in a Canine Model of Ischemic Stroke
    van der Marel, Kajo
    Chueh, Ju-Yu
    Wakhloo, Ajay K.
    Gounis, Matthew J.
    STROKE, 2015, 46