Recovering intrinsic fluorescence by Monte Carlo modeling

被引:14
|
作者
Muller, Manfred [1 ]
Hendriks, Benno H. W. [1 ]
机构
[1] Philips Res, Minimally Invas Healthcare Dept, NL-5656 AE Eindhoven, Netherlands
关键词
biomedical optics; fluorescence spectroscopy; laser-induced fluorescence; simulations; multiple scattering; fiber optic applications; DIFFUSION-THEORY MODEL; OPTICAL SPECTROSCOPY; TURBID MEDIA; IN-VIVO; TISSUE; REFLECTANCE; LIGHT;
D O I
10.1117/1.JBO.18.2.027009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a novel way to recover intrinsic fluorescence in turbid media based on Monte Carlo generated look-up tables and making use of a diffuse reflectance measurement taken at the same location. The method has been validated on various phantoms with known intrinsic fluorescence and is benchmarked against photon-migration methods. This new method combines more flexibility in the probe design with fast reconstruction and showed similar reconstruction accuracy as found in other reconstruction methods. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.18.2.027009]
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Mesh-based Monte Carlo code for fluorescence modeling in complex tissues with irregular boundaries
    Wilson, Robert H.
    Chen, Leng-Chun
    Lloyd, William
    Kuo, Shiuhyang
    Marcelo, Cynthia
    Feinberg, Stephen E.
    Mycek, Mary-Ann
    NOVEL BIOPHOTONIC TECHNIQUES AND APPLICATIONS, 2011, 8090
  • [32] Fluorescence fluctuation spectroscopy with strong background fluorescence - An Monte Carlo approach
    Liu, G
    Chen, B
    Meng, FB
    Ma, H
    Chen, DY
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (11) : 1379 - 1383
  • [33] Intrinsic Auger signal profiles derived by Monte Carlo analysis
    Ding, ZJ
    Shimizu, R
    Goto, K
    APPLIED SURFACE SCIENCE, 1996, 100 : 15 - 19
  • [34] Monte Carlo simulation of zinc protoporphyrin fluorescence in the retina
    Chen, Xiaoyan
    Lane, Stephen
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2010, 7572
  • [35] Simulation of Intrinsic Resolution of Scintillation Camera in Monte Carlo Environment
    Dong, Xianling
    Saad, Wira Hidayat Mohd
    Adnan, Wan Azizun Wan
    Hashim, Suhairul
    Hassan, Nor Pai'za Mohd.
    Nordin, Abd Jalil
    Saripan, M. Iqbal
    2013 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING APPLICATIONS (IEEE ICSIPA 2013), 2013, : 11 - 14
  • [36] A Monte Carlo study of the intrinsic viscosity of semiflexible ring polymers
    Ono, Yuki
    Ida, Daichi
    POLYMER JOURNAL, 2015, 47 (07) : 487 - 492
  • [37] A Monte Carlo study of the intrinsic viscosity of semiflexible ring polymers
    Yuki Ono
    Daichi Ida
    Polymer Journal, 2015, 47 : 487 - 492
  • [38] MONTE CARLO SIMULATION OF FLUORESCENCE CORRELATION SPECTROSCOPY DATA
    Kosovan, Peter
    Uhlik, Filip
    Kuldova, Jitka
    Stepanek, Miroslav
    Limpouchova, Zuzana
    Prochazka, Karel
    Benda, Ales
    Humpolickova, Jana
    Hof, Martin
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (03) : 207 - 222
  • [39] Skin fluorescence model based on the Monte Carlo technique
    Churmakov, DY
    Meglinski, IV
    Piletsky, SA
    Greenhalgh, DA
    SARATOV FALL MEETING 2002: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE IV, 2002, 5068 : 326 - 333
  • [40] Uncertainty Analysis for Fluorescence Tomography with Monte Carlo Method
    Reinbacher-Koestinger, Alice
    Freiberger, Manuel
    Scharfetter, Hermann
    DIFFUSE OPTICAL IMAGING III, 2011, 8088