Tissue mimicking materials for the detection of prostate cancer using shear wave elastography: A validation study

被引:32
作者
Cao, Rui [1 ]
Huang, Zhihong [1 ]
Varghese, Tomy [2 ]
Nabi, Ghulam [3 ,4 ]
机构
[1] Univ Dundee, Sch Engn Phys & Math, Dundee DD1 4HN, Scotland
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Sch Med, Acad Sect Urol, Dundee DD1 9SY, Scotland
[4] Ninewells Hosp, Dundee DD1 9SY, Scotland
关键词
ultrasound; elastography; prostate cancer; strain; shear wave elastography; ACOUSTIC RADIATION FORCE; INTENSITY-FOCUSED-ULTRASOUND; IN-VIVO DEMONSTRATION; SOFT-TISSUE; PHANTOMS; ELASTICITY; BREAST; FUSION;
D O I
10.1118/1.4773315
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Quantification of stiffness changes may provide important diagnostic information and aid in the early detection of cancers. Shear wave elastography is an imaging technique that assesses tissue stiffness using acoustic radiation force as an alternate to manual palpation reported previously with quasistatic elastography. In this study, the elastic properties of tissue mimicking materials, including agar, polyacrylamide (PAA), and silicone, are evaluated with an objective to determine material characteristics which resemble normal and cancerous prostate tissue. Methods: Acoustic properties and stiffness of tissue mimicking phantoms were measured using compressional mechanical testing and shear wave elastography using supersonic shear imaging. The latter is based on the principles of shear waves generated using acoustic radiation force. The evaluation included tissue mimicking materials (TMMs) within the prostate at different positions and sizes that could mimic cancerous and normal prostate tissue. Patient data on normal and prostate cancer tissues quantified using biopsy histopathology were used to validate the findings. Pathologist reports on histopathology were blinded to mechanical testing and elastographic findings. Results: Young's modulus values of 86.2 +/- 4.5 and 271.5 +/- 25.7 kPa were obtained for PAA mixed with 2% Al2O3 particles and silicone, respectively. Young's modulus of TMMs from mechanical compression testing showed a clear trend of increasing stiffness with an increasing percentage of agar. The silicone material had higher stiffness values when compared with PAA with Al2O3. The mean Young's modulus value in cancerous tissue was 90.5 +/- 4.5 kPa as compared to 93.8 +/- 4.4 and 86.2 +/- 4.5 kPa obtained with PAA with 2% Al2O3 phantom at a depth of 52.4 and 36.6 mm, respectively. Conclusions: PAA mixed with Al2O3 provides the most suitable tissue mimicking material for prostate cancer tumor material, while agar could form the surrounding background to simulate normal prostate tissue. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4773315]
引用
收藏
页数:9
相关论文
共 50 条
  • [21] CORRELATION OF STIFFNESS OF PROSTATE CANCER MEASURED BY SHEAR WAVE ELASTOGRAPHY WITH GRADE GROUP: A PRELIMINARY STUDY
    Dai, Wen-Bin
    Xu, Jun
    Yu, Bo
    Chen, Lin
    Chen, Yue
    Zhan, Jiaz
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02) : 288 - 295
  • [22] Elastography in prostate gland imaging and prostate cancer detection
    Tyloch, Dominik
    Tyloch, Janusz
    Adamowicz, Jan
    Juszczak, Kajetan
    Ostrowski, Adam
    Warsinski, Patryk
    Wilamowski, Jacek
    Ludwikowska, Joanna
    Drewa, Tomasz
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (04) : 515 - 523
  • [23] Validation of shear wave elastography in skeletal muscle
    Eby, Sarah F.
    Song, Pengfei
    Chen, Shigao
    Chen, Qingshan
    Greenleaf, James F.
    An, Kai-Nan
    JOURNAL OF BIOMECHANICS, 2013, 46 (14) : 2381 - 2387
  • [24] Assessment of Tumor Stiffness With Shear Wave Elastography in a Human Prostate Cancer Xenograft Implantation Model
    Wang, Yiru
    Yao, Binwei
    Li, Hongfei
    Zhang, Yan
    Gao, Hanjing
    Gao, Yabin
    Peng, Ruiyun
    Tang, Jie
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (05) : 955 - 963
  • [25] Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study
    Ji, Yonghao
    Ruan, Litao
    Ren, Wei
    Dun, Guoliang
    Liu, Jianxue
    Zhang, Yaoren
    Wan, Qinyun
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1097)
  • [26] Accuracy of shear wave elastography for the diagnosis of prostate cancer: A meta-analysis
    Sang, Liang
    Wang, Xue-mei
    Xu, Dong-yang
    Cai, Yun-fei
    SCIENTIFIC REPORTS, 2017, 7
  • [27] Evaluation of materials used for vascular anastomoses using shear wave elastography
    Bernal, Miguel
    Sen, Indrani
    Urban, Matthew W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (07)
  • [28] Histoscanning and shear wave ultrasound elastography for prostate cancer diagnosis
    Amosov, A. V.
    Krupinov, G. E.
    Arkad'ev, A. M.
    Semendiev, R. I.
    Vorob'ev, A. V.
    Lumpov, I. S.
    ONKOUROLOGIYA, 2016, 12 (02): : 74 - 79
  • [29] Integrating shear wave elastography and multiparametric MRI for accurate prostate cancer diagnosis
    Jiang, Wei
    Lai, Bingjia
    Li, Xiumei
    Liu, Yuanfang
    Xu, Longjiahui
    He, Shaoyun
    Gao, Ming
    AMERICAN JOURNAL OF CANCER RESEARCH, 2025, 15 (01): : 348 - 362
  • [30] Characterization of ventral incisional hernia and repair using shear wave elastography
    Chaudhry, Anuj
    Fernandez-Moure, Joseph S.
    Shajudeen, Peer Shafeeq
    Van Eps, Jeffrey L.
    Cabrera, Fernando J.
    Weiner, Bradley K.
    Dunkin, Brian J.
    Tasciotti, Ennio
    Righetti, Raffaella
    JOURNAL OF SURGICAL RESEARCH, 2017, 210 : 244 - 252