Tissue mimicking materials for the detection of prostate cancer using shear wave elastography: A validation study

被引:31
|
作者
Cao, Rui [1 ]
Huang, Zhihong [1 ]
Varghese, Tomy [2 ]
Nabi, Ghulam [3 ,4 ]
机构
[1] Univ Dundee, Sch Engn Phys & Math, Dundee DD1 4HN, Scotland
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Sch Med, Acad Sect Urol, Dundee DD1 9SY, Scotland
[4] Ninewells Hosp, Dundee DD1 9SY, Scotland
关键词
ultrasound; elastography; prostate cancer; strain; shear wave elastography; ACOUSTIC RADIATION FORCE; INTENSITY-FOCUSED-ULTRASOUND; IN-VIVO DEMONSTRATION; SOFT-TISSUE; PHANTOMS; ELASTICITY; BREAST; FUSION;
D O I
10.1118/1.4773315
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Quantification of stiffness changes may provide important diagnostic information and aid in the early detection of cancers. Shear wave elastography is an imaging technique that assesses tissue stiffness using acoustic radiation force as an alternate to manual palpation reported previously with quasistatic elastography. In this study, the elastic properties of tissue mimicking materials, including agar, polyacrylamide (PAA), and silicone, are evaluated with an objective to determine material characteristics which resemble normal and cancerous prostate tissue. Methods: Acoustic properties and stiffness of tissue mimicking phantoms were measured using compressional mechanical testing and shear wave elastography using supersonic shear imaging. The latter is based on the principles of shear waves generated using acoustic radiation force. The evaluation included tissue mimicking materials (TMMs) within the prostate at different positions and sizes that could mimic cancerous and normal prostate tissue. Patient data on normal and prostate cancer tissues quantified using biopsy histopathology were used to validate the findings. Pathologist reports on histopathology were blinded to mechanical testing and elastographic findings. Results: Young's modulus values of 86.2 +/- 4.5 and 271.5 +/- 25.7 kPa were obtained for PAA mixed with 2% Al2O3 particles and silicone, respectively. Young's modulus of TMMs from mechanical compression testing showed a clear trend of increasing stiffness with an increasing percentage of agar. The silicone material had higher stiffness values when compared with PAA with Al2O3. The mean Young's modulus value in cancerous tissue was 90.5 +/- 4.5 kPa as compared to 93.8 +/- 4.4 and 86.2 +/- 4.5 kPa obtained with PAA with 2% Al2O3 phantom at a depth of 52.4 and 36.6 mm, respectively. Conclusions: PAA mixed with Al2O3 provides the most suitable tissue mimicking material for prostate cancer tumor material, while agar could form the surrounding background to simulate normal prostate tissue. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4773315]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Shear Wave Elastography for Detection of Prostate Cancer: A Preliminary Study
    Woo, Sungmin
    Kim, Sang Youn
    Cho, Jeong Yeon
    Kim, Seung Hyup
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (03) : 346 - 355
  • [2] Transrectal shear wave elastography for detection of prostate cancer
    Keskin, Emin Taha
    Kaplanoglu, Veysel
    Senocak, Cagri
    Basar, Halil
    Bozkurt, Omer Faruk
    UROLOGIA JOURNAL, 2023, 90 (02) : 230 - 235
  • [3] COMPARISON OF STRAIN AND SHEAR WAVE ELASTOGRAPHY IN PROSTATE CANCER DETECTION
    Tyloch, Dominik Janusz
    Tyloch, Janusz Ferdynand
    Adamowicz, Jan
    Neska-Dlugosz, Izabela
    Grzanka, Dariusz
    Van Breda, Shane
    Drewa, Tomasz
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (03): : 889 - 900
  • [4] A Basic Study of Ultrasonic Shear Wave Elastography in Tissue-mimicking Phantoms
    Rengaraju, V.
    da Silva, A. F. F.
    Sack, I.
    Kargel, Ch.
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 55 - +
  • [5] Radiomics Approach to the Detection of Prostate Cancer Using Multiparametric MRI: A Validation Study Using Prostate-Cancer-Tissue-Mimicking Phantoms
    Alshomrani, Faisal
    Alsaedi, Basim S. O.
    Wei, Cheng
    Szewczyk-Bieda, Magdalena
    Gandy, Stephen
    Wilson, Jennifer
    Huang, Zhihong
    Nabi, Ghulam
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [6] Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer
    Sarfraz Ahmad
    Rui Cao
    Tomy Varghese
    Luc Bidaut
    Ghulam Nabi
    Surgical Endoscopy, 2013, 27 : 3280 - 3287
  • [7] Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer
    Ahmad, Sarfraz
    Cao, Rui
    Varghese, Tomy
    Bidaut, Luc
    Nabi, Ghulam
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (09): : 3280 - 3287
  • [8] Shear Wave Elastography for Detection of Prostate Cancer: A Preliminary Study (vol 15, pg 346, 2014)
    Woo, Sungmin
    Kim, Sang Youn
    Cho, Jeong Yeon
    Kim, Seung Hyup
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1373 - 1373
  • [9] A comparison of hyperelastic constitutive models applicable to shear wave elastography (SWE) data in tissue-mimicking materials
    Rosen, D. P.
    Jiang, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05):
  • [10] Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study
    Ji, Yonghao
    Ruan, Litao
    Ren, Wei
    Dun, Guoliang
    Liu, Jianxue
    Zhang, Yaoren
    Wan, Qinyun