Real-time reference A-line subtraction and saturation artifact removal using graphics processing unit for high-frame-rate Fourier-domain optical coherence tomography video imaging

被引:19
作者
Huang, Yong [1 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21210 USA
关键词
optical coherence tomography; interventional imaging; reference fixed pattern artifact removal; saturation A-scan correction; graphics processing unit;
D O I
10.1117/1.OE.51.7.073203
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Variations in the spectral shape and the amplitude of the optical coherence tomography (OCT) signal and reference cause fixed-pattern noise and light reflected from a highly specular surface might cause saturation artifacts. In real-time video-rate OCT imaging, these effects make the OCT video image appear unstable and difficult to view. To eliminate these problems, we implemented real-time reference A-line subtraction and saturation detection and correction on standard Fourier-domain optical coherence tomography (FD-OCT) video imaging frame-by-frame. This real-time OCT data processing method eliminates the need for the physical reference measurement procedure and automatically detects and corrects saturated A-scans if there is any within one frame. This technique is also robust to the reference and signal amplitude variations, and provides higher signal-to-noise ratio compared to the normal fixed-reference subtraction method. To implement an effective interventional OCT imaging system, the technique was integrated along with other graphics processing unit-based OCT processing techniques [resampling, dispersion compensation, fast Fourier transform, log-scaling, and soft-thresholding]. The real-time fixed-pattern artifact-free FD-OCT imaging was achieved at 70 frames/s for a frame size of 1000 (lateral) by 1024 (axial) pixels. The theoretical maximum processing and rendering rate was measured to be 266; 000 A-scans/s. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.OE.51.7.073203]
引用
收藏
页数:5
相关论文
共 13 条
[1]   Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography [J].
Asrani, Sanjay ;
Sarunic, Marinko ;
Santiago, Cecilia ;
Izatt, Joseph .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (06) :765-771
[2]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[3]   Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source [J].
Choma, MA ;
Hsu, K ;
Izatt, JA .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[4]   Artefact reduction for cell migration visualization using spectral domain optical coherence tomography [J].
Hofer, Bernd ;
Povazay, Boris ;
Hermann, Boris ;
Rey, Sara M. ;
Kajic, Vedran ;
Tumlinson, Alexandre ;
Powell, Kate ;
Matz, Gerald ;
Drexler, Wolfgang .
JOURNAL OF BIOPHOTONICS, 2011, 4 (05) :355-367
[5]   Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming [J].
LaRocca, Francesco ;
Chiu, Stephanie J. ;
McNabb, Ryan P. ;
Kuo, Anthony N. ;
Izatt, Joseph A. ;
Farsiu, Sina .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1524-1538
[6]  
Leitgeb RA, 2008, BIOL MED PHYS BIOMED, P176
[7]   Reference spectrum extraction and fixed-pattern noise removal in optical coherence tomography [J].
Moon, Sucbei ;
Lee, Sang-Won ;
Chen, Zhongping .
OPTICS EXPRESS, 2010, 18 (24) :24395-24404
[8]   Processing and rendering of Fourier domain optical coherence tomography images at a line rate over 524 kHz using a graphics processing unit [J].
Rasakanthan, Janarthanan ;
Sugden, Kate ;
Tomlins, Peter H. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (02)
[9]   Real-time resampling in Fourier domain optical coherence tomography using a graphics processing unit [J].
Van der Jeught, Sam ;
Bradu, Adrian ;
Podoleanu, Adrian Gh .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
[10]   Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit [J].
Watanabe, Yuuki ;
Itagaki, Toshiki .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)