Miniaturized fiber in-line Mach-Zehnder interferometer based on inner air cavity for high-temperature sensing

被引:81
作者
Hu, T. Y. [1 ]
Wang, Y. [1 ]
Liao, C. R. [1 ]
Wang, D. N. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
关键词
HIGH-SENSITIVITY; OPTICAL-FIBER; THERMAL-STABILITY; BRAGG GRATINGS; SENSOR;
D O I
10.1364/OL.37.005082
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a miniaturized fiber in-line Mach-Zehnder interferometer based on an inner air cavity adjacent to the fiber core for high-temperature sensing. The inner air cavity is fabricated by femtosecond laser micromachining and the fusion splicing technique. Such a device is robust and insensitive to ambient refractive index change, and has high temperature sensitivity of similar to 43.2 pm/degrees C, up to 1000 degrees C, and low cross sensitivity to strain. (C) 2012 Optical Society of America
引用
收藏
页码:5082 / 5084
页数:3
相关论文
共 15 条
  • [1] Ultrahigh-temperature regenerated gratings in boron-codoped germanosilicate optical fiber using 193 nm
    Bandyopadhyay, Somnath
    Canning, John
    Stevenson, Michael
    Cook, Kevin
    [J]. OPTICS LETTERS, 2008, 33 (16) : 1917 - 1919
  • [2] Optical fiber long-period grating sensors
    Bhatia, V
    Vengsarkar, AM
    [J]. OPTICS LETTERS, 1996, 21 (09) : 692 - 694
  • [3] Fiber Bragg gratings with enhanced thermal stability
    Brambilla, G
    Rutt, H
    [J]. APPLIED PHYSICS LETTERS, 2002, 80 (18) : 3259 - 3261
  • [4] Miniature fiber-optic high temperature sensor based on a hybrid structured Fabry-Perot interferometer
    Choi, Hae Young
    Park, Kwan Seoh
    Park, Seong Jun
    Paek, Un-Chul
    Lee, Byeong Ha
    Choi, Eun Seo
    [J]. OPTICS LETTERS, 2008, 33 (21) : 2455 - 2457
  • [5] Long-term thermal stability tests at 1000 °C of silica fibre Bragg gratings made with ultrafast laser radiation
    Grobnic, D.
    Smelser, C. W.
    Mihailov, S. J.
    Walker, R. B.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (05) : 1009 - 1013
  • [6] Fiber Mach-Zehnder interferometer based on microcavities for high-temperature sensing with high sensitivity
    Jiang, L.
    Yang, J.
    Wang, S.
    Li, B.
    Wang, M.
    [J]. OPTICS LETTERS, 2011, 36 (19) : 3753 - 3755
  • [7] Prestressed Fiber Bragg Grating With High Temperature Stability
    Li, Yuhua
    Yang, Minwei
    Liao, Changrui
    Wang, Dongning
    Lu, Jian
    Lu, Peixiang
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2011, 29 (10) : 1555 - 1559
  • [8] High-temperature sensing with tapers made of microstructured optical fiber
    Monzón-Hernández, D
    Minkovich, VP
    Villatoro, J
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2006, 18 (1-4) : 511 - 513
  • [9] High temperature fiber sensor with high sensitivity based on core diameter mismatch
    Nguyen, Linh Viet
    Hwang, Dusun
    Moon, Sucbei
    Moon, Dae Seung
    Chung, Youngjoo
    [J]. OPTICS EXPRESS, 2008, 16 (15): : 11369 - 11375
  • [10] Ultracompact Intrinsic Micro Air-Cavity Fiber Mach-Zehnder Interferometer
    Park, Minkyu
    Lee, Sejin
    Ha, Woosung
    Kim, Dae-Kyu
    Shin, Woojin
    Sohn, Ik-Bu
    Oh, Kyunghwan
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2009, 21 (15) : 1027 - 1029