Comparison of dynamic contour tonometry and Goldmann applanation tonometry in relation to central corneal thickness in primary congenital glaucoma

被引:5
作者
Silva Jordao, Marcelo Lopes [1 ]
Costa, Vital Paulino [2 ]
Veronese Rodrigues, Maria de Lourdes [1 ]
Paula, Jayter Silva [1 ,3 ]
机构
[1] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Ophthalmol, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Sch Med Sci Campinas, Dept Ophthalmol, Campinas, SP, Brazil
[3] Hosp Clin Ribeirao Preto, Dept Oftalmol Otorrinolaringol & Cirurgia Cabeca, BR-14049900 Sao Paulo, Brazil
关键词
Intraocular pressure; Primary congenital glaucoma; Corneal thickness; Dynamic contour tonometry; OCULAR HYPERTENSION TREATMENT; INTRAOCULAR-PRESSURE MEASUREMENTS; RESPONSE ANALYZER;
D O I
10.1007/s00417-012-2027-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare intraocular pressure (IOP) measurements obtained with dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT), and to investigate their relationship to central corneal thickness (CCT) in primary congenital glaucoma (PCG) eyes. Thirty-one eyes of 31 PCG patients (25.7 +/- 7.2 years old) were examined. PCG was defined as elevated IOP, enlarged corneal diameter (buphthalmos), Haab's striae and abnormal findings at gonioscopy. The mean of three measurements of GAT, DCT (quality scores 1 and 2), and CCT were obtained and assessed for agreement by means of Bland-Altman plot and for Spearman correlation test. Mean CCT was 534 +/- 72.3 mu m (range: 430 to 610 mu m). Mean IOP measurements were 15.1 +/- 4.2 mmHg (range: 5.5 to 22.7 mmHg) for DCT and 14.5 +/- 5.6 mmHg (range: 7.0 to 34.0 mmHg) for GAT (P = 0.244). Spearman correlation tests showed that IOP difference (DCT - GAT) was not correlated with CCT (r (2) = 0.023, P = 0.417). IOP measurements by DCT were weakly but statistically correlated with those obtained with GAT (r(2) = 0.213, P = 0.0089). Bland-Altman analysis revealed poor agreement between DCT and GAT readings, considering the 95 % confidence intervals of +/- 10.45 mmHg. The differences between DCT and GAT readings were not influenced by CCT in this series of patients. Considering the weak correlation and the poor agreement observed between GAT and DCT measurements and that they both may be affected by corneal biomechanical changes, these methods should not be used interchangeably, and may possibly give no meaningful IOP values in PCG patients.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 27 条
[1]   Null Mutations in LTBP2 Cause Primary Congenital Glaucoma [J].
Ali, Manir ;
McKibbin, Martin ;
Booth, Adam ;
Parry, David A. ;
Jain, Payal ;
Riazuddin, S. Amer ;
Hejtmancik, J. Fielding ;
Khan, Shaheen N. ;
Firasat, Sabika ;
Shires, Mike ;
Gilmour, David F. ;
Towns, Katherine ;
Murphy, Anna-Louise ;
Azmanov, Dimitar ;
Tournev, Ivailo ;
Cherninkova, Sylvia ;
Jafri, Hussain ;
Raashid, Yasmin ;
Toomes, Carmel ;
Craig, Jamie ;
Mackey, David A. ;
Kalaydjieva, Luba ;
Riazuddin, Sheikh ;
Inglehearn, Chris F. .
AMERICAN JOURNAL OF HUMAN GENETICS, 2009, 84 (05) :664-671
[2]   Changes in central corneal thickness over time - The Ocular Hypertension Treatment Study [J].
Brandt, James D. ;
Gordon, Mae O. ;
Beiser, Julia A. ;
Lin, Shan C. ;
Alexander, Monica Y. ;
Kass, Michael A. .
OPHTHALMOLOGY, 2008, 115 (09) :1550-1556
[3]   Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) [J].
Brandt, JD ;
Beiser, JA ;
Kass, MA ;
Gordon, MO .
OPHTHALMOLOGY, 2001, 108 (10) :1779-1788
[4]   Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness [J].
Doyle, A ;
Lachkar, Y .
JOURNAL OF GLAUCOMA, 2005, 14 (04) :288-292
[5]   Dynamic contour tonometry for post-LASIK intraocular pressure measurements [J].
Duba, I ;
Wirthlin, AC .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (05) :347-350
[6]  
Gilbert C., 2003, VISUAL IMPAIRMENT BL
[7]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[8]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[9]   Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry [J].
Hsu, S-Y ;
Sheu, M-M ;
Hsu, A-H ;
Wu, K-Y ;
Yeh, J-I ;
Tien, J-N ;
Tsai, R-K .
EYE, 2009, 23 (07) :1582-1588
[10]   Incorporating corneal pachymetry into the management of glaucoma [J].
Iester, Michele ;
Mete, Maurizio ;
Figus, Michele ;
Frezzotti, Paolo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) :1623-1628