Radiation exposure in hand surgery: Mini versus standard C-arm

被引:52
作者
Athwal, GS
Bueno, RA
Wolfe, SW
机构
[1] Univ Western Ontario, Hand & Upper Limb Ctr, St Josephs Hlth Ctr, London, ON N6A 4L6, Canada
[2] Hosp Special Surg, Div Hand Surg, New York, NY 10021 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2005年 / 30A卷 / 06期
关键词
exposure; fluoroscopy; hand surgery; mini C-arm; radiation;
D O I
10.1016/j.jhsa.2005.06.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The use of intraoperative fluoroscopy in hand surgery is common. Two types of fluoroscopic units are available: the mini C-arm and the standard C-arm. There is little literature on the radiation exposure from the mini C-arm, therefore, the primary goal of this study was to quantify and compare the amount of radiation exposure to members of the surgical learn (surgeon, first assistant, nurse, anesthesiologist) using both standard and mini C-arms in a simulated wrist surgery setup. Mini C-arm positioning was also examined to determine the safest configuration to minimize radiation exposure to surgeons. Methods: Radiation dosimeters were used to test 2 commercially available fluoroscopy units in a simulated wrist surgery setup with a cadaveric upper extremity. Several different configurations of the C-arms were tested to determine radiation exposure rates to surgeons and the operating room staff. Results: The mean in-beam radiation exposures with the use of the mini and standard C-arms were 3,720 mR/h and 6,540 mR/h, respectively. The mini C-arm had universally less radiation exposure than the standard C-arm in the clinical configurations tested. The safest configuration of mini C-arm use to minimize radiation exposure was with the surgeon standing on the image intensifier side of the unit as compared with the source side. Mini C-arm radiation exposure to the hands, groin, chest, and thyroid of the operating surgeons were well below the National Council of Radiation Protection and Measurement's annual dose limits. Conclusions: In the clinical configurations tested in this study the mini C-arm had lower radiation exposures than the standard C-arm. To reduce radiation exposure maximally surgeons should stand behind the lead-encased image intensifier and should use techniques to reduce exposure.
引用
收藏
页码:1310 / 1316
页数:7
相关论文
共 17 条
[1]   Radiation exposure with use of the mini-c-arm for routine orthopaedic imaging procedures [J].
Badman, BL ;
Rill, L ;
Butkovich, B ;
Arreola, M ;
Griend, RAV .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :13-17
[2]  
BERAL V, 2004, LOW DOSE EXTRAPOLATI
[3]   Ionising radiation during internal fixation of extracapsular neck of femur fractures [J].
Giannoudis, PV ;
McGuigan, J ;
Shaw, DL .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :469-472
[4]   HISTORY, CURRENT STATUS, AND TRENDS OF RADIATION PROTECTION STANDARDS [J].
HENDEE, WR .
MEDICAL PHYSICS, 1993, 20 (05) :1303-1314
[5]  
Herscovici D, 2000, CLIN ORTHOP RELAT R, P126
[6]  
*HLTH PHYS SOC, 2004, HLTH PHYS SOC DIR HD
[7]  
KEREIAKES JG, 1980, HDB RAD DOSES NUCL M, P241
[8]   Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" [J].
Mehlman, CT ;
DiPasquale, TG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :392-398
[9]   Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing [J].
Muller, LP ;
Suffner, J ;
Wenda, K ;
Mohr, W ;
Rommens, PM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :461-468
[10]  
NCRP, 1993, 116 NCRP