A Fractional Order PI (FOPI) Controller Design For Shunt Active Power Filter To Improve The Power Quality

被引:0
|
作者
Srivastava, Abhishek [1 ]
Das, Dushmanta Kumar [1 ]
Gurumurthy, Gandikota [1 ]
机构
[1] NIT Nagaland, Dept EEE, Nagaland 797103, India
关键词
Harmonic Elimination; Power Quality Improvement; Shunt Active Power Filter (SAPF); Fractional order Proportional Integral (FOPI) controller; SLIDING-MODE; IMPLEMENTATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a Fractional Order Proportional Integral (FOPI) controller based shunt active power filter (SAPF) is proposed. The FOPI controller is designed to have a constant voltage of the DC-Link of the SAPF which is used for the elimination of harmonics and there by to improve the power quality. To design the FOPI controller, phase margin, gain crossover frequency and velocity error constant are taken as desired specifications. For harmonic current extraction and gate signal generation, instantaneous active and reactive power (P-Q) approach and pulse width modulation technique (PWM) have been used. In order to show the effectiveness of the proposed FOPI controller in maintaining the a constant voltage and in eliminating harmonics thereby improving the power quality of the system, SAPF model is developed in MATLAB/SIMULINK and the effectiveness of the designed FOPI controller is analyzed. The results obtained with FOPI controller illustrates that the FOPI makes the system to have a the constant voltage of the DC-Link and compensates the harmonic components present in the system.
引用
收藏
页码:2761 / 2766
页数:6
相关论文
共 50 条
  • [21] A developed DQ control method for shunt active power filter to improve power quality in transformers
    Al-Gahtani, Saad F.
    Elbarbary, Z. M. S.
    Irshad, Shaik Mohammad
    PLOS ONE, 2024, 19 (07):
  • [22] Power Quality Improvement Using Shunt Active Power Filter
    Patil, Sagar S.
    Metri, R. A.
    2017 1ST IEEE INTERNATIONAL CONFERENCE ON DATA MANAGEMENT, ANALYTICS AND INNOVATION (ICDMAI), 2017, : 152 - 156
  • [23] Fuzzy logic PWM current controller based shunt active power filter for power quality compensation
    Bayindir, K. Cagatay
    Tuemay, Mehmet
    Cuma, M. Ugras
    ENGINEERING INTELLIGENT SYSTEMS FOR ELECTRICAL ENGINEERING AND COMMUNICATIONS, 2008, 16 (01): : 5 - 16
  • [24] Shunt Active Power filter Apparent Power For Design Process
    Kouzou, A.
    Khaldi, B. S.
    Mahmoudi, M. O.
    Boucherit, M. S.
    2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 1402 - +
  • [25] Advanced Active Power Filter to Improve Power Quality
    Gurguiatu, Gelu
    Balanuta, Ciprian
    Rosu, Emil
    Munteanu, Toader
    Dumitrescu, Mariana
    Raducan, Elena
    INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION JOINT CONFERENCE, 2011, : 484 - 489
  • [26] Adaptive Current Control with PI-Fuzzy Compound Controller for Shunt Active Power Filter
    Fei, Juntao
    Ma, Kaiqi
    Zhang, Shenglei
    Yan, Weifeng
    Yuan, Zhuli
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [27] Simulation of DC-side Voltage for Shunt Active Power Filter with Fuzzy PI Controller
    Zhou, Kaijie
    Cao, Peipei
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 771 - 774
  • [28] An Intelligent PI Controller-Based Hybrid Series Active Power Filter for Power Quality Improvement
    Baliyan, Arjun
    Jamil, Majid
    Rizwan, M.
    Alsaidan, Ibrahim
    Alaraj, Muhannad
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [29] A Modified Fuzzy Hysteresis Controller For Shunt Active Power Filter
    Koya, Shameer A.
    Alsumiri, Mohammed
    2018 RENEWABLE ENERGIES, POWER SYSTEMS & GREEN INCLUSIVE ECONOMY (REPS-GIE), 2018,
  • [30] Application of the automatic disturbance controller in the shunt active power filter
    Zhong, Qing
    Wu, Jie
    Xu, Zheng
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2002, 26 (16): : 22 - 25