Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH

被引:120
作者
Sun, Phillip Zhe [1 ]
Sorensen, A. Gregory [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Athinoula A Martinos Ctr Biomed Imaging,Dept Radi, Charlestown, MA 02129 USA
关键词
amide proton transfer; APT; chemical exchange saturation transfer; CEST; pH;
D O I
10.1002/mrm.21653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical exchange saturation transfer (CEST) MRI has been shown capable of detecting dilute labile protons and abnormal tissue glucose/oxygen metabolism, and thus, may serve as a complementary imaging technique to the conventional MRI methods. CEST imaging, however, is also dependent on experimental parameters such as the power, duration, and waveform of the irradiation RF pulse. As a result, its sensitivity and specificity for microenvironment properties such as pH is not optimal. In this study, the dependence of CEST contrast on experimental parameters was solved and an iterative compensation algorithm was proposed that corrects the experimentally measured CEST contrast from the concomitant RF irradiation effects. The proposed algorithm was verified with both numerical simulation and experimental measurements from a tissue-like pH phantom, and showed that pH derived from the compensated CEST imaging agrees reasonably well with pH-electrode measurements within 0.1 pH unit. In sum, our study validates the use of a correction algorithm to compensate CEST imaging from concomitant RF irradiation effects for accurate calibration of the chemical exchange rate, and demonstrates the feasibility of pH imaging with CEST MRI.
引用
收藏
页码:390 / 397
页数:8
相关论文
共 40 条
[1]   Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications [J].
Aime, S ;
Barge, A ;
Delli Castelli, D ;
Fedeli, F ;
Mortillaro, A ;
Nielsen, FU ;
Terreno, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :639-648
[2]   A paramagnetic MRI-CEST agent responsive to lactate concentration [J].
Aime, S ;
Delli Castelli, D ;
Fedeli, F ;
Terreno, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (32) :9364-9365
[3]   Magnetic resonance imaging profiles predict clinical response to early reperfusion: The diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) study [J].
Albers, Gregory W. ;
Thijs, Vincent N. ;
Wechsle, Lawrence ;
Kemp, Stephanie ;
Schlaug, Gottfried ;
Skalabrin, Elaine ;
Bammer, Roland ;
Kakuda, Wataru ;
Lansberg, Maarten G. ;
Shuaib, Ashfaq ;
Coplin, William ;
Hamilton, Scott ;
Moseley, Michael ;
Marks, Michael P. .
ANNALS OF NEUROLOGY, 2006, 60 (05) :508-517
[4]   TRITIUM PROTON MAGNETIZATION TRANSFER AS A PROBE OF CROSS RELAXATION IN AQUEOUS LIPID BILAYER SUSPENSIONS [J].
CECKLER, TL ;
BALABAN, RS .
JOURNAL OF MAGNETIC RESONANCE, 1991, 93 (03) :572-588
[5]   HYDROGEN-EXCHANGE [J].
ENGLANDER, SW ;
DOWNER, NW ;
TEITELBAUM, H .
ANNUAL REVIEW OF BIOCHEMISTRY, 1972, 41 :903-+
[6]   STUDY OF MODERATELY RAPID CHEMICAL EXCHANGE REACTIONS BY MEANS OF NUCLEAR MAGNETIC DOUBLE RESONANCE [J].
FORSEN, S ;
HOFFMAN, RA .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (11) :2892-&
[7]  
González RG, 2006, AM J NEURORADIOL, V27, P728
[8]  
Gröhn OHJ, 1998, J CEREBR BLOOD F MET, V18, P911
[9]   A reproducible model of middle cerebral artery occlusion in mice: Hemodynamic, biochemical, and magnetic resonance imaging [J].
Hata, R ;
Mies, G ;
Wiessner, C ;
Fritze, K ;
Hesselbarth, D ;
Brinker, G ;
Hossmann, KA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (04) :367-375
[10]   Magnetization transfer in MRI: a review [J].
Henkelman, RM ;
Stanisz, GJ ;
Graham, SJ .
NMR IN BIOMEDICINE, 2001, 14 (02) :57-64