Improved scatter correction for SPECT images: A Monte Carlo study

被引:8
作者
Bong, JK [1 ]
Son, HK [1 ]
Lee, JD [1 ]
Kim, HJ [1 ]
机构
[1] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Dept Radiol, Seoul 120751, South Korea
关键词
energy window; extended triple energy window (ETEW) scatter correction; SPECT; triple energy window (TEW) scatter correction;
D O I
10.1109/TNS.858202
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose the extended triple energy window (ETEW) method that improves quantitation and contrast in SPECT images. ETEW is a modification of the triple energy window (TEW) method which corrects for scatter by using abutted scatter rejection windows, which can overestimate or underestimate scatter. ETEW is compared to TEW using Monte Carlo simulated data for point sources as well as hot and cold spheres in a cylindrical water phantom. Various main energy window widths were simulated. Both TEW and ETEW improved image contrast and recovery coefficients. Estimated scatter components by TEW were not proportional to the true scatter components when main energy window widths of 10%, 15%, and 20% were simulated. ETEW resulted in scatter that was directly proportional to the true scatter. ETEW improves image quantitation and quality of SPECT image data by more accurately correcting for scatter.
引用
收藏
页码:1263 / 1270
页数:8
相关论文
共 25 条
[1]  
AXELSSON B, 1984, J NUCL MED, V25, P490
[2]  
BUVAT I, 1995, J NUCL MED, V36, P1476
[3]   WINDOW SELECTION FOR DUAL PHOTOPEAK WINDOW SCATTER CORRECTION IN TC-99M IMAGING [J].
DEVRIES, DJ ;
KING, MA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) :2771-2778
[4]   DEVELOPMENT AND VALIDATION OF A MONTE-CARLO SIMULATION OF PHOTON TRANSPORT IN AN ANGER CAMERA [J].
DEVRIES, DJ ;
MOORE, SC ;
ZIMMERMAN, RE ;
MUELLER, SP ;
FRIEDLAND, B ;
LANZA, RC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) :430-438
[5]   Quantitative 131I SPECT with triple energy window compton scatter correction [J].
Dewaraja, Y ;
Li, J ;
Koral, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3109-3114
[6]  
FLOYD CE, 1985, J NUCL MED, V26, P403
[7]   INFLUENCE OF PHANTOM SIZE, SHAPE, AND DENSITY, AND COLLIMATOR SELECTION ON THE DUAL PHOTOPEAK WINDOW SCATTER CORRECTION METHOD [J].
HADEMENOS, GJ ;
KING, MA ;
LJUNGBERG, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (01) :364-368
[8]   A MONTE-CARLO INVESTIGATION OF THE DUAL PHOTOPEAK WINDOW SCATTER CORRECTION METHOD [J].
HADEMENOS, GJ ;
LJUNGBERG, M ;
KING, MA ;
GLICK, SJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (02) :179-185
[9]  
ICHIHARA T, 1993, J NUCL MED, V34, P2216
[10]  
JASZCZAK RJ, 1984, J NUCL MED, V25, P893