Simulation of PD Pulse Propagation in MV XLPE Cable

被引:0
|
作者
Liu, Hong-Jing [1 ]
Ren, Zhi-Gang [1 ]
Zhou, Feng [1 ]
Wu, Lin-Lin [1 ]
Huang, Shan [1 ]
Gao, Xu-Ze [2 ]
机构
[1] Beijing Elect Power Co, Res Inst, Beijing 100075, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian, Shaanxi, Peoples R China
来源
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING 2018 (ICITEE '18) | 2018年
关键词
XLPE cable; PD pulse; high frequency attenuation;
D O I
10.1145/3148453.3306288
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Partial discharge is a useful diagnostic method for a wide range of power apparatus. In the case of XLPE cable, partial discharge can detect various insulation defects, for example workmanship-induced defects, as well as cavities and electrical trees in the dielectric. When a PD pulse propagates trough a cable, caused by the attenuation, the waveform of PD pulse is changed. For a PD measurement, it is critical to know what happens when a PD pulse propagates through a cable, therefore this paper give a direction that the shape and the amplitude of PD pulse changes during its propagation, in particular high frequency content of a PD pulse is attenuated relatively fast, and compared with the cable without joint, when PD pulse propagates through a joint, the amplitude will decay very seriously.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Analysis of electrical tree propagation in XLPE power cable insulation
    Bao, Minghui
    Yin, Xiaogen
    He, Junjia
    PHYSICA B-CONDENSED MATTER, 2011, 406 (08) : 1556 - 1560
  • [22] Analytic solutions for pulse propagation in shielded power cable for symmetric and asymmetric PD pulses
    Oussalah, Naima
    Zebboudj, Youcef
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (05) : 1264 - 1270
  • [23] Comparing wave propagation characteristics of MV XLPE cable and covered-conductor overhead line using time domain refiectometry technique
    Hashmi, G. M.
    Papazyan, R.
    Lehtonen, M.
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, 2007, : 350 - +
  • [24] Investigation of PD signal propagation characteristics in XLPE cables
    Vakilian, M
    Blackburn, TR
    Phung, BT
    Zhang, H
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1863 - 1868
  • [25] A study on the correlation between the PD pattern and the aspect of electrical trees propagation in the XLPE insulation of the underground power transmission cable
    Koo, JY
    Lee, JS
    Kim, JT
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 161 - 164
  • [26] Assessment of MV XLPE cable aging state based on PSO-XGBoost algorithm
    Pan, Qiaosheng
    Zhang, Chi
    Wei, Xinyuan
    Wan, Aode
    Wei, Zeping
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
  • [27] Simulation of transformer PD pulse propagation and monitoring for a 500 kV substation
    Dong, XZ
    Zhu, DH
    Wang, CC
    Tan, KX
    Liu, YL
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (06) : 803 - 813
  • [28] Inference of PD pulse propagation in polymeric cables through computer simulation
    Cavallini, A.
    Montanari, G. C.
    Chandrasekar, S.
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 581 - +
  • [29] Diagnosis on MV XLPE power cable by using frequency variance leakage current analysis
    Rahman, Muhammad Azizi Abdul
    Ghosh, Prodipto Sankar
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1154 - +
  • [30] Research on condition assessment of XLPE cable based on signal propagation characteristics
    Chi, Peng
    Qin, Yuxuan
    Tao, Yunchun
    Liang, Rui
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195