State of Harmonization of 24 Serum Albumin Measurement Procedures and Implications for Medical Decisions

被引:44
作者
Bachmann, Lorin M. [1 ]
Yu, Min [2 ]
Boyd, James C. [2 ]
Bruns, David E. [2 ]
Miller, W. Greg [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Pathol, 403 N 13th St,Rm 620G, Richmond, VA 23298 USA
[2] Univ Virginia, Dept Pathol, Charlottesville, VA 22903 USA
关键词
INTRADIALYTIC PARENTERAL-NUTRITION; RENAL-DISEASE; PREDICTOR; TESTOSTERONE; PERFORMANCE; INDICATORS; MORTALITY; EQUATION; CALCIUM; IMPACT;
D O I
10.1373/clinchem.2016.262899
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Measurements of serum and plasma albumin are widely used in medicine, including as indicators of quality of patient care in renal dialysis centers. METHODS: Pools were prepared from residual patient serum (n = 50) and heparin plasma (n = 48) from patients without renal disease, and serum from patients with kidney failure before hemodialysis (n = 53). Albumin was measured in all samples and in ERM-DA470k/IFCC reference material (RM) by 3 immunochemical, 9 bromcresol green (BCG), and 12 bromcresol purple (BCP) methods. RESULTS: Two of 3 immunochemical procedures, 5 of 9 BCG, and 10 of 12 BCP methods recovered the RM value within its uncertainty. One immunochemical and 3 BCG methods were biased vs the RM value. Random error components were small for all measurement procedures. The Tina-quant immunochemical method was chosen as the reference measurement procedure based on recovery and results of error analyses. Mean biases for BCG vs Tina-quant were 1.5% to 13.9% and were larger at lower albumin concentrations. BCP methods' mean biases were -5.4% to 1.2% irrespective of albumin concentration. Biases for plasma samples were generally higher than for serum samples for all method types. For most measurement procedures, biases were lower for serum from patients on hemodialysis vs patients without kidney disease. CONCLUSIONS: Significant differences among immunochemical, BCG, and BCP methods compromise interpretation of serum. albumin results. Guidelines and calculations for clinical management of kidney and other diseases must consider the method used for albumin measurement until harmonization can be achieved. (C) 2016 American Association for Clinical Chemistry
引用
收藏
页码:770 / 779
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 2000, Am J Kidney Dis, V35, pS1, DOI DOI 10.1053/AJKD.2000.V35.AAJKD03517
[2]   State of the Art for Measurement of Urine Albumin: Comparison of Routine Measurement Procedures to Isotope Dilution Tandem Mass Spectrometry [J].
Bachmann, Lorin M. ;
Nilsson, Goran ;
Bruns, David E. ;
McQueen, Matthew J. ;
Lieske, John C. ;
Zakowski, Jack J. ;
Miller, W. Greg .
CLINICAL CHEMISTRY, 2014, 60 (03) :471-480
[3]   Intradialytic parenteral nutrition does not improve survival in malnourished hemodialysis patients: A 2-year multicenter, prospective, randomized study [J].
Cano, Noel J. M. ;
Fouque, Denis ;
Roth, Hubert ;
Aparicio, Michel ;
Azar, Raymond ;
Canaud, Bernard ;
Chauveau, Philippe ;
Combe, Christian ;
Laville, Maurice ;
Leverve, Xavier M. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 18 (09) :2583-2591
[4]  
Centers for Medicare and Medicaid Services, FISC YEAR FY 2016 EN
[5]  
Centers for Medicare & Medicaid Services, END STAG REN DIS ESR
[6]  
Centers for Medicare &Medicaid Services, 2008, ESRD SURV TRAIN INT
[7]   Albumin-corrected calcium and ionized calcium in stable haemodialysis patients [J].
Clase, CM ;
Norman, GL ;
Beecroft, ML ;
Churchill, DN .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (11) :1841-1846
[8]   Conversion between bromcresol green- and bromcresol purple-measured albumin in renal disease [J].
Clase, CM ;
St Pierre, MW ;
Churchill, DN .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (09) :1925-1929
[9]  
Corbello J, 2009, PRACT GASTROENTEROL, V33, P13
[10]  
Daugirdas JT, 2015, AM J KIDNEY DIS, V66, P884, DOI 10.1053/j.ajkd.2015.07.015