An Efficient Pulse Compression Method of Chirp-Coded Excitation in Medical Ultrasound Imaging

被引:32
|
作者
Yoon, Changhan [1 ]
Lee, Wooyoul [1 ]
Chang, Jin Ho [1 ,2 ,3 ]
Song, Tai-Kyong [1 ]
Yoo, Yangmo [1 ,2 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul, South Korea
[2] Sogang Univ, Interdisciplinary Program Integrated Biotechnol, Seoul, South Korea
[3] Sogang Univ, Sogang Inst Adv Technol, Seoul, South Korea
关键词
HIGH-FRAME RATE; SYSTEM; SIGNALS;
D O I
10.1109/TUFFC.2013.2815
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Coded excitation can improve the SNR in medical ultrasound imaging. In coded excitation, pulse compression is applied to compress the elongated coded signals into a short pulse, which typically requires high computational complexity, i.e., a compression filter with a few hundred coefficients. In this paper, we propose an efficient pulse compression method of chirp-coded excitation, in which the pulse compression is conducted with complex baseband data after downsampling, to lower the computational complexity. In the proposed method, although compression is conducted with the complex data, the L-fold downsampling is applied for reducing both data rates and the number of compression filter coefficients; thus, total computational complexity is reduced to the order of 1/L-2. The proposed method was evaluated with simulation and phantom experiments. From the simulation and experiment results, the proposed pulse compression method produced similar axial resolution compared with the conventional pulse compression method with negligible errors, i.e., >36 dB in signal-to-error ratio (SER). These results indicate that the proposed method can maintain the performance of pulse compression of chirp-coded excitation while substantially reducing computational complexity.
引用
收藏
页码:2225 / 2229
页数:5
相关论文
共 50 条
  • [31] The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: Implications for high-frequency nonlinear imaging
    Doyley, M.M. (m.doyley@rochester.edu), 1600, Acoustical Society of America (133):
  • [32] The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: Implications for high-frequency nonlinear imaging
    Shekhar, Himanshu
    Doyley, Marvin M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (05): : 3145 - 3158
  • [33] Coded excitation and nonlinear pulse compression in pulse-inversion fundamental imaging
    Shen, Che-Chou
    Cheng, Yun-Chien
    Li, Pai-Chi
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1744 - 1747
  • [34] A real-time chirp-coded imaging system with tissue attenuation compensation
    Ramalli, A.
    Guidi, F.
    Boni, E.
    Tortoli, P.
    ULTRASONICS, 2015, 60 : 65 - 75
  • [35] Nonlinear coded excitation method for ultrasound contrast imaging
    Borsboom, JMG
    Chin, CT
    de Jong, N
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (02): : 277 - 284
  • [36] Contrast-specific imaging of histotripsy: Chirp-coded subharmonic imaging combined with Volterra Filtering
    Trivedi, Vishwas
    Wallach, Emily
    Bader, Kenneth B.
    Shekhar, Himanshu
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [37] Quinary excitation method for pulse compression ultrasound measurements
    Cowell, D. M. J.
    Freear, S.
    ULTRASONICS, 2008, 48 (02) : 98 - 108
  • [38] Ultrasonic Imaging of Human Tooth using Chirp-Coded Nonlinear Time Reversal Acoustics
    Dos Santos, Serge
    Domenjoud, Mathieu
    Prevorovsky, Zdenek
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 913 - 918
  • [39] MEDICAL ULTRASOUND IMAGING USING PULSE-COMPRESSION
    RAO, N
    MEHRA, S
    ELECTRONICS LETTERS, 1993, 29 (08) : 649 - 651
  • [40] Pulse-Inversion Chirp-Coded Weld Harmonic Imaging (PI-CWHI) of Friction Stir Welded Butt-Joint
    Tabatabaeipour, M.
    Hettler, J.
    Sewell, N. T.
    Wright, J. R.
    Wright, J. C. S.
    Delrue, S.
    Van den Abeele, K.