An Efficient Pulse Compression Method of Chirp-Coded Excitation in Medical Ultrasound Imaging

被引:32
|
作者
Yoon, Changhan [1 ]
Lee, Wooyoul [1 ]
Chang, Jin Ho [1 ,2 ,3 ]
Song, Tai-Kyong [1 ]
Yoo, Yangmo [1 ,2 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul, South Korea
[2] Sogang Univ, Interdisciplinary Program Integrated Biotechnol, Seoul, South Korea
[3] Sogang Univ, Sogang Inst Adv Technol, Seoul, South Korea
关键词
HIGH-FRAME RATE; SYSTEM; SIGNALS;
D O I
10.1109/TUFFC.2013.2815
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Coded excitation can improve the SNR in medical ultrasound imaging. In coded excitation, pulse compression is applied to compress the elongated coded signals into a short pulse, which typically requires high computational complexity, i.e., a compression filter with a few hundred coefficients. In this paper, we propose an efficient pulse compression method of chirp-coded excitation, in which the pulse compression is conducted with complex baseband data after downsampling, to lower the computational complexity. In the proposed method, although compression is conducted with the complex data, the L-fold downsampling is applied for reducing both data rates and the number of compression filter coefficients; thus, total computational complexity is reduced to the order of 1/L-2. The proposed method was evaluated with simulation and phantom experiments. From the simulation and experiment results, the proposed pulse compression method produced similar axial resolution compared with the conventional pulse compression method with negligible errors, i.e., >36 dB in signal-to-error ratio (SER). These results indicate that the proposed method can maintain the performance of pulse compression of chirp-coded excitation while substantially reducing computational complexity.
引用
收藏
页码:2225 / 2229
页数:5
相关论文
共 50 条
  • [21] Use of a chirp-coded excitation method in order to improve geometrical and acoustical measurements in wood specimen
    Lasaygues, Philippe
    Arciniegas, Andres
    Brancheriau, Loic
    Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 : 348 - 351
  • [22] Histotripsy Bubble Cloud Contrast With Chirp-Coded Excitation in Preclinical Models
    Wallach, Emily L.
    Shekhar, Himanshu
    Flores-Guzman, Fernando
    Hernandez, Sonia L.
    Bader, Kenneth B.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (02) : 787 - 794
  • [23] Plane Wave Ultrasound Imaging Under Low Signal-to-Noise Ratio Circumstances with Delay Multiply and Sum and Chirp-Coded Excitation
    Zhang, Shun
    Wang, Yuanyuan
    Yu, Jinhua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1686 - 1691
  • [24] High-Volume-Rate 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming With Chirp-Coded Excitation
    Zhou, Jian
    Wei, Siyuan
    Jintamethasawat, Rungroj
    Sampson, Richard
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (08) : 1346 - 1358
  • [25] Potential of coded excitation in medical ultrasound imaging
    Misaridis, TX
    Gammelmark, K
    Jorgensen, CH
    Lindberg, N
    Thomsen, AH
    Pedersen, MH
    Jensen, JA
    ULTRASONICS, 2000, 38 (1-8) : 183 - 189
  • [26] Contrast-Enhanced Imaging of Histotripsy Bubble Clouds Using Chirp-Coded Excitation and Volterra Filtering
    Trivedi, Vishwas V.
    Wallach, Emily L.
    Bader, Kenneth B.
    Shekhar, Himanshu
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (09) : 989 - 998
  • [27] Chirp-coded ultrasound for localization of linear and nonlinear scatterers in isotropic media
    Lints, M.
    Salupere, A.
    dos Santos, S.
    e-Journal of Nondestructive Testing, 2024, 29 (06):
  • [28] A high frequency endoscopic ultrasound imaging method combining chirp coded excitation and compressed sensing
    Wang, Ninghao
    Li, Xinze
    Xu, Jie
    Jiao, Yang
    Cui, Yaoyao
    Jian, Xiaohua
    ULTRASONICS, 2022, 121
  • [29] Pseudo Chirp-Barker-Golay Coded Excitation in Ultrasound Imaging
    Wang, Mingquan
    Cong, Shan
    Zhang, Shi
    PROCEEDINGS OF THE 30TH CHINESE CONTROL AND DECISION CONFERENCE (2018 CCDC), 2018, : 4035 - 4039
  • [30] Chirp-coded robust synthetic aperture technique for medical endoscopic ultrasonography
    LI Ming CHEN Xiaodong LI Yan WANG Yi YU Daoyin~+ {Key Laboratory Opto-electronics Information Technology
    Chinese Journal of Acoustics, 2012, 31 (04) : 455 - 465