Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom

被引:3
作者
de las Heras, Hugo [1 ]
Minniti, Ronaldo [2 ]
Wilson, Sean [3 ]
Mitchell, Chad [3 ]
Skopec, Marlene [4 ]
Brunner, Claudia C. [1 ]
Chakrabarti, Kish [1 ]
机构
[1] US FDA, Silver Spring, MD 20993 USA
[2] NIST, Gaithersburg, MD 20899 USA
[3] Walter Reed Natl Mil Med Ctr, Bethesda, MD 20889 USA
[4] NIH, Bethesda, MD 20892 USA
关键词
PERFUSION COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; RADIOCHROMIC FILM; ENERGY-DEPENDENCE; DOSIMETRY; PATIENT;
D O I
10.1093/rpd/nct171
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A straightforward method is presented to estimate peak skin doses (PSDs) delivered by computed tomography (CT) scanners. The measured PSD values are related to the well-known volume CT dose index (CTDIvol), displayed on the console of CT scanners. PSD measurement estimates were obtained, in four CT units, by placing radiochromic film on the surface of a CTDI head phantom. Six different X-ray tube currents including the maximum allowed value were used to irradiate the phantom. PSD and CTDIvol were independently measured and later related to the CTDIvol value displayed on the console. A scanner-specific relationship was found between the measured PSD and the associated CTDIvol displayed on the console. The measured PSD values varied between 27 and 136 mGy among all scanners when the routine head scan parameters were used. The results of this work allow relating the widely used CTDIvol to an actual radiation dose delivered to the skin of a patient.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 40 条
[1]  
American Association of Physicists in Medicine, 2011, AAPM DOS CHECK GUID
[2]  
American Association of Physicists in Medicine, 2012, ARD BRAIN PERF CT PR
[3]  
American Association of Physicists in Medicine, 2011, 204 AM ASS PHYS
[4]  
American Association of Physicists in Medicine, 2008, 96 AM ASS PSYCH MED
[5]  
[Anonymous], 2009, 160 NCRP
[6]  
[Anonymous], 2009, N13112009 ANSI
[7]   Radiation doses in cerebral perfusion computed tomography: patient and phantom study [J].
Arandjic, D. ;
Bonutti, F. ;
Biasizzo, E. ;
Ciraj-Bjelac, O. ;
Floreani, M. ;
Giustizieri, M. ;
Iaiza, F. ;
Inkoom, S. ;
Tommasini, G. ;
Padovani, R. .
RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) :459-464
[8]   Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair [J].
Balter, Stephen ;
Hopewell, John W. ;
Miller, Donald L. ;
Wagner, Louis K. ;
Zelefsky, Michael J. .
RADIOLOGY, 2010, 254 (02) :326-341
[9]   CT dosimetry: comparison of measurement techniques and devices [J].
Bauhs, John A. ;
Vrieze, Thomas J. ;
Primak, Andrew N. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2008, 28 (01) :245-253
[10]   DOSES TO SKIN DURING DYNAMIC PERFUSION COMPUTED TOMOGRAPHY OF THE LIVER [J].
Beganovic, Adnan ;
Sefic-Pasic, Irmina ;
Skopljak-Beganovic, Amra ;
Kristic, Spomenka ;
Sunjic, Svjetlana ;
Mekic, Amra ;
Gazdic-Santic, Maja ;
Drljevic, Advan ;
Samek, Davorin .
RADIATION PROTECTION DOSIMETRY, 2013, 153 (01) :106-111