Wound-Rotor Induction Machine Model With Saturation and High-Frequency Effects

被引:0
|
作者
Xu, Yuanzhen [1 ]
Aliprantis, Dionysios C. [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
来源
2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM) | 2014年
关键词
Electromagnetic interference; generators; induction motors; modeling; saturation magnetization; wind power generation; MOTOR MODEL; PARAMETERIZATION; OVERVOLTAGE; SYSTEMS; CABLE; TIME;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper sets forth a novel model of a woundrotor induction machine, which incorporates magnetic saturation of the main flux path and high-frequency effects. The model's experimental parameterization procedure is described in detail. This consists of standstill frequency response tests, and a test for determining the machine's magnetizing characteristic and turns ratio. Time-domain simulations are used to highlight the capabilities of the proposed model, and to compare its predictions with those of a classical model at both transient and steady states.
引用
收藏
页码:1838 / 1844
页数:7
相关论文
共 50 条
  • [1] Thermal Model and Analysis of Wound-Rotor Induction Machine
    Boglietti, Aldo
    Cavagnino, Andrea
    Popescu, Mircea
    Staton, Dave
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (05)
  • [2] Control of wound-rotor induction machine
    Ruppert, E
    Sanchez, B
    1997 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, PROCEEDINGS, VOLS 1 AND 2, 1997, : 97 - 102
  • [3] On the wound-rotor induction machine control
    Filho, ER
    Sanchez, VAB
    1997 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE RECORD, 1997, : TB391 - TB393
  • [4] Leakage flux saturation effects on the transient performance of wound-rotor induction motors
    Jabr, Hany A.
    Kar, Narayan C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (07) : 1280 - 1289
  • [5] Wound-rotor synchronous machine dq modeling with saturation for transient analysis
    Wisniewski, Teodor
    Vannier, Jean-Claude
    Lorcet, Bruno
    Saint-Michel, Jacques
    Jannot, Xavier
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [6] A New Reliable Fault Index for Rotor Dissymmetry Detection in Wound-Rotor Induction Machine
    Gritli, Y.
    Rossi, C.
    Casadei, D.
    Filippetti, F.
    Bellini, A.
    Capolino, G. -A.
    2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2015, : 468 - 473
  • [7] Accurate Rotor Fault Detection in Doubly-Fed Wound-Rotor Induction Machine
    Gritli, Y.
    Tani, A.
    Rossi, C.
    Casadei, D.
    Filippetti, F.
    2017 6TH INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP): RENEWABLE ENERGY IMPACT, 2017, : 756 - 760
  • [8] Experimental Identification of a Coupled-Circuit Model for the Digital Twin of a Wound-Rotor Induction Machine
    Aboubi, Fatma Zohra
    Maiga, Abdrahamane
    Cros, Jerome
    Kamwa, Innocent
    ENERGIES, 2024, 17 (08)
  • [9] Vector Control for Double-Inverter-Fed Wound-Rotor Induction Machine
    Mykhalskyi, V. M.
    Sobolev, V. M.
    Chopyk, V. V.
    Polishchuk, S. Y.
    Shapoval, I. A.
    2018 IEEE 38TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2018, : 552 - 557
  • [10] A Measurement-Based Wide-Frequency Model for Aircraft Wound-Rotor Synchronous Machine
    Zhao, Dan
    Shen, Ke
    Liu, Weiguo
    Lang, Lang
    Liang, Peixin
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (07)