In the Canadian residential sector, the end-uses of appliances, lighting, and plug loads (ALP) account for 16% of total end-use energy consumption. In an effort to reduce the impacts of this energy consumption, electricity technologies such as solar photovoltaics and smart appliances are being adopted. Evaluation of their performance requires an understanding of residential electricity use patterns. Building simulation tools can estimate the time-step performance of such technologies, but require accurate and representative ALP electricity profiles as an input. Sub-metered datasets lack in quantity and thus overall representativeness of the sector. Meanwhile, large, representative datasets are becoming available through electricity smart-metering programs, but usually consist only of whole-house electricity load and lack summary household characteristics (e.g. occupancy, floor space, appliance descriptions). However, homes which are not electrically heated (space, water) or cooled may function as ALP load profiles for simulation. This research addresses these loads with a new method of distinguishing non-electrically heated and cooled homes from a broad dataset of whole-house profiles. The method originates from a comparison of two electricity load datasets: (i) "smart-meter" 15-min time-step whole-house data for 160 homes spanning three years, and (ii) "sub-metered" 1-min time-step data for 23 residential homes. This comparison also speaks to the usefulness of whole-house electricity smart-meter information to building performance simulation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:212 / 222
页数:11
相关论文
共 22 条
[1]   Synthetically derived profiles for representing occupant-driven electric loads in Canadian housing [J].
Armstrong, Marianne M. ;
Swinton, Mike C. ;
Ribberink, Hajo ;
Beausoleil-Morrison, Ian ;
Millette, Jocelyn .
JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2009, 2 (01) :15-30
[2]   Time series distance-based methods for non-intrusive load monitoring in residential buildings [J].
Basu, Kaustav ;
Debusschere, Vincent ;
Douzal-Chouakria, Ahlame ;
Bacha, Seddik .
ENERGY AND BUILDINGS, 2015, 96 :109-117
[3]  
CANMET Energy Technology Center (CETC), 2016, HOT2000 V11 2B86
[4]   What can we learn from high-frequency appliance-level energy metering? Results from a field experiment [J].
Chen, Victor L. ;
Delmas, Magali A. ;
Kaiser, William J. ;
Locke, Stephen L. .
ENERGY POLICY, 2015, 77 :164-175
[5]   Identifying trends in the use of domestic appliances from household electricity consumption measurements [J].
Firth, S. ;
Lomas, K. ;
Wright, A. ;
Wall, R. .
ENERGY AND BUILDINGS, 2008, 40 (05) :926-936
[6]   Energy performance of a solar mixed-use community [J].
Hachem-Vermette, C. ;
Cubi, E. ;
Bergerson, J. .
SUSTAINABLE CITIES AND SOCIETY, 2016, 27 :145-151
[7]  
Johnson G., 2016, APPL THERM ENG
[8]   Energy, cost, and emission end-use profiles of homes: An Ontario (Canada) case study [J].
Koksal, Merih Aydinalp ;
Rowlands, Ian H. ;
Parker, Paul .
APPLIED ENERGY, 2015, 142 :303-316
[9]   Battery storage system for residential electricity peak demand shaving [J].
Leadbetter, Jason ;
Swan, Lukas .
ENERGY AND BUILDINGS, 2012, 55 :685-692
[10]   Electricity Demand Profile of Australian Low Energy Houses [J].
Lee, Seungho ;
Whaley, David ;
Saman, Wasim .
6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 :91-100