Regions of Active Damping Control for LCL Filters

被引:0
作者
Parker, S. G. [1 ]
McGrath, B. P. [1 ]
Holmes, D. G. [1 ]
机构
[1] RMIT Univ, Sch Elect & Comp Engn, Melbourne, Vic, Australia
来源
2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2012年
关键词
STABILITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The control of a grid connected voltage source inverter (VSI) with an LCL filter is a very challenging task, since the LCL network causes a resonance phenomenon near to the control stability boundary. While many active damping methods have been proposed to overcome this issue, the role that PWM transport delay plays in the effectiveness of these strategies is still not fully resolved. This paper presents a theoretical discrete time analysis frame work that identifies three distinct regions of LCL filter resonance - a high resonant frequency region where active damping isn't required; a critical resonant frequency where a controller cannot stabilise the system; and a low resonant frequency region where active damping is essential. Suitable controllers are then proposed for the two stable regions, with gain calculations that allow for the greatest system bandwidth and damping. Simulation and experimental results verify the presented analysis.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
[21]   Sensorless Active Damping Strategy for Parallel Interleaved Voltage Source Power Converters with LCL Filter [J].
Samanes, Javier ;
Gubia, Eugenio .
2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, :3632-3639
[22]   Discrete-Time Active Damping of LCL-Resonance by Proportional Capacitor Current Feedback [J].
Wagner, Martin ;
Barth, Tobias ;
Alvarez, Rodrigo ;
Ditmanson, Chester ;
Bernet, Steffen .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (06) :3911-3920
[23]   A Systematic Approach via IIR Filters for Enhancing the Robustness of LCL-Type Shunt Active Power Filters to Grid Impedance [J].
Yang, Lei ;
Yang, Jiaqiang ;
Gao, Min ;
Chen, Yunlong ;
Zhang, Xiang .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (05) :5095-5107
[24]   Internal Model-Based Active Resonance Damping Current Control of a Grid-Connected Voltage-Sourced Converter With an LCL Filter [J].
Leitner, Stefan ;
Yazdanian, Mehrdad ;
Ziaeinejad, Saleh ;
Mehrizi-Sani, Ali ;
Muetze, Annette .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (06) :6025-6036
[25]   Enhanced Stability of Capacitor-Current Feedback Active Damping for LCL-Filtered Grid Converters [J].
Xin, Zhen ;
Wang, Xiongfei ;
Loh, Poh Chiang ;
Blaabjerg, Frede .
2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, :4729-4736
[26]   On the Limits of the Capacitor-Voltage Active Damping for Grid-Connected Power Converters with LCL Filter [J].
Samanes, Javier ;
Gubia, Eugenio .
2018 IEEE 19TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2018,
[27]   State-Space Control for LCL Filters: Converter Versus Grid Current Measurement [J].
Rahman, F. M. Mahafugur ;
Pirsto, Ville ;
Kukkola, Jarno ;
Routimo, Mikko ;
Hinkkanen, Marko .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (06) :6608-6618
[28]   A Time Delay Compensation Method Based on Area Equivalence For Active Damping of an LCL-Type Converter [J].
Chen, Chen ;
Xiong, Jian ;
Wan, Zhiqiang ;
Lei, Ji ;
Zhang, Kai .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :762-772
[29]   Active Damping of LCL-Filter Resonance Using a Digital Resonant-Notch (Biquad) Filter [J].
Pan, Donghua ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Gong, Hong .
2018 20TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'18 ECCE EUROPE), 2018,
[30]   A Capacitor-Current-Feedback Positive Active Damping Control Strategy for LCL-Type Grid-Connected Inverter to Achieve High Robustness [J].
Li, Shaojie ;
Lin, Hua .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) :6462-6474