Optimized electrode arrangement in solar air heater

被引:25
作者
Kasayapanand, N [1 ]
Kiatsiriroat, T
机构
[1] King Mongkuts Univ Technol Thonburi, Sch Energy & Mat, Bangkok 10140, Thailand
[2] Chiang Mai Univ, Dept Mech Engn, Chiang Mai 50200, Thailand
关键词
computational fluid dynamics; electrohydrodynamic; electric field; heat transfer enhancement; finite difference technique;
D O I
10.1016/j.renene.2005.04.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Laminar forced convection inside the solar air heater with various wire electrode arrangements are numerically examined for heat transfer enhancement using electrohydrodynamic technique. The electric field is generated by the wire electrodes charged with DC high voltage ranging from 7.5 to 17.5 M Reynolds number corresponding to the flow considered is between 100 and 2000. The numerical modeling of computational fluid dynamics includes the interactions among electric field, flow field, and temperature field. It is found that the enhancement of heat transfer coefficient with the presence of electric field increases in relation with the supplied voltage but decreases when the Reynolds number and the distance between electrode and channel surface are augmented. The optimized electrode arrangement, which obtains the best heat transfer enhancement is investigated incorporating with the pressure drop consideration. The heat transfer enhancement is also depended on the number of electrodes per length and the channel dimension. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:439 / 455
页数:17
相关论文
共 25 条
[1]   Corona discharge simulation in wire-duct electrostatic precipitator [J].
Anagnostopoulos, J ;
Bergeles, G .
JOURNAL OF ELECTROSTATICS, 2002, 54 (02) :129-147
[2]   CALCULATION OF FORCED FLOW AND HEAT-TRANSFER AROUND A CYLINDER IN CROSS-FLOW [J].
CHUN, W ;
BOEHM, RF .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1989, 15 (01) :101-122
[3]   Numerical investigation of heat transfer from a heated oscillating cylinder in a cross flow [J].
Fu, WS ;
Tong, BH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (14) :3033-3043
[4]   Numerical study on natural convection inside the channel between the flat-plate cover and sine-wave absorber of a cross-corrugated solar air heater [J].
Gao, WF ;
Lin, WX ;
Lu, ER .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (02) :145-151
[5]   MIXED-CONVECTION FLOW AND HEAT-TRANSFER IN THE ENTRY REGION OF A HORIZONTAL RECTANGULAR DUCT [J].
INCROPERA, FP ;
KNOX, AL ;
MAUGHAN, JR .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1987, 109 (02) :434-439
[6]  
KARNIADAKIS GE, 1988, INT J HEAT MASS TRAN, V31, P407
[7]   Effect of the electrode arrangements in a tube bank on the characteristic of electrohydrodynamic heat transfer enhancement: Low Reynolds number [J].
Kasayapanand, N ;
Tiansuwan, J ;
Asvapoositkul, W ;
Vorayos, N ;
Kiatsiriroat, T .
JOURNAL OF ENHANCED HEAT TRANSFER, 2002, 9 (5-6) :229-242
[8]  
KASAYAPANAND N, IN PRESS INT J COMMU
[9]   A mathematical model of electrostatic field in wires-plate electrostatic precipitators [J].
Lami, E ;
Mattachini, F ;
Sala, R ;
Vigl, H .
JOURNAL OF ELECTROSTATICS, 1997, 39 (01) :1-21
[10]  
LANDAU LD, 1963, ELECTROHYDRODYNAMICS