Monocyte Chemoattractant Protein 1 Expression in Synovial Fluid of Patients With Total Hip Arthroplasty

被引:4
作者
Montesi, Monica [1 ]
Beraudi, Alina [1 ]
Stea, Susanna [1 ]
Ancarani, Cristina [1 ]
Traina, Francesco [1 ,2 ]
Toni, Aldo [1 ,2 ]
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli Ortopedia Traumatol & Chirurg, Bologna, Italy
关键词
Total hip arthroplasty; Chemokines; Monocyte chemoattractant protein; Synovial fluid; Ceramic bearings; Metal bearings; Wear particles; INDUCE CHEMOKINE SECRETION; ON-METAL BEARINGS; RHEUMATOID-ARTHRITIS; DISEASE-ACTIVITY; REPLACEMENT; OSTEOLYSIS; ALUMINA; MARKERS; JOINTS; BONE;
D O I
10.1111/j.1525-1594.2011.01400.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monocyte chemoattractant protein 1 (MCP-1) is a member of the chemokines family that stimulates monocyte chemotaxis and whose expression is induced during osseous inflammation. Total hip arthroplasty (THA) now uses ceramic-on-ceramic (cer-cer) or metal-on-metal (met-met) coupling that is considered the bearing of new generation, with improved performance compared with the previous polyethylene bearings. While the ceramic on ceramic is universally considered highly biocompatible, met-met coupling can induce hypersensitivity correlated to immunological response. This study aimed at quantifying the MCP-1 levels in synovial fluid of THA patients with these two articular couplings; synovial fluid of osteoarthritic patients who underwent primary THA was used as a control. The presence of wear particles originating from the prostheses was also assessed in the synovial fluid by scanning electron microscopy and energy dispersive X-ray spectroscopy. The MCP-1 levels in the synovial fluid of 17 patients with met-met coupling were significantly higher than in 13 patients with cer-cer coupling and in seven controls; median MCP-1 level was 919 pg/mL in the cer-cer group, 4274 pg/mL in the met-met group, and 326 pg/mL in the control group. No correlation was found between MCP-1 levels and the presence of wear particles in the synovial fluid, time from surgery, or periprosthetic osteolysis. We conclude that the presence of the prosthesis is responsible for an increase in the level of MCP-1; moreover, the significantly higher level of this chemokine in met-met coupling can be related to inflammatory and possibly hypersensitivity processes induced by metal ions.
引用
收藏
页码:487 / 491
页数:5
相关论文
共 30 条
  • [1] Immunologic Adverse Reaction Associated with Low-carbide Metal-on-metal Bearings in Total Hip Arthroplasty
    Aroukatos, Panagiotis
    Repanti, Maria
    Repantis, Thomas
    Bravou, Vassiliki
    Korovessis, Panagiotis
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (08) : 2135 - 2142
  • [2] Assessment of Five Interleukins in Human Synovial Fluid as Possible Markers for Aseptic Loosening of Hip Arthroplasty
    Beraudi, Alina
    Stea, Susanna
    Cremonini, Sara
    Visentin, Manuela
    Toni, Aldo
    [J]. ARTIFICIAL ORGANS, 2009, 33 (07) : 538 - 543
  • [3] THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT
    BOUTIN, P
    CHRISTEL, P
    DORLOT, JM
    MEUNIER, A
    DEROQUANCOURT, A
    BLANQUAERT, D
    HERMAN, S
    SEDEL, L
    WITVOET, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12): : 1203 - 1232
  • [4] Metal is not inert: Role of metal ions released by biocorrosion in aseptic loosening-Current concepts
    Cadosch, Dieter
    Chan, Erwin
    Gautschi, Oliver P.
    Filgueira, Luis
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 91A (04) : 1252 - 1262
  • [5] Cobalt ions induce chemokine secretion in a variety of systemic cell lines
    Devitt, Brian M.
    Queally, Joseph M.
    Vioreanu, Mihai
    Butler, Joseph S.
    Murray, David
    Doran, Peter P.
    O'Byrne, John M.
    [J]. ACTA ORTHOPAEDICA, 2010, 81 (06) : 756 - 764
  • [6] In vitro cytotoxicity evaluation of elemental ions released from different prosthodontic materials
    Elshahawy, Waleed M.
    Watanabe, Ikuya
    Kramer, Phillip
    [J]. DENTAL MATERIALS, 2009, 25 (12) : 1551 - 1555
  • [7] POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS
    ENGH, CA
    BOBYN, JD
    GLASSMAN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 45 - 55
  • [8] Bone remodeling, particle disease and individual susceptibility to periprosthetic osteolysis
    Gallo, J.
    Raska, M.
    Mrazek, F.
    Petrek, M.
    [J]. PHYSIOLOGICAL RESEARCH, 2008, 57 (03) : 339 - 349
  • [9] The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
    Gallo, Jiri
    Slouf, Miroslav
    Goodman, Stuart B.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (01) : 171 - 177
  • [10] Cellular chemotaxis induced by wear particles from joint replacements
    Goodman, Stuart B.
    Ma, Ting
    [J]. BIOMATERIALS, 2010, 31 (19) : 5045 - 5050