Patterning piezoelectric thin film PVDF-TrFE based pressure sensor for catheter application

被引:240
作者
Sharma, Tushar [1 ]
Je, Sang-Soo [1 ]
Gill, Brijesh [2 ]
Zhang, John X. J. [1 ]
机构
[1] Univ Texas Austin, Austin, TX 78712 USA
[2] Univ Texas Hlth Sci Ctr Houston, Houston, TX USA
基金
美国国家科学基金会;
关键词
Piezoelectricity; Pressure sensor; Thin film PVDF-TrFE; Lithography; Microfabrication; Catheter;
D O I
10.1016/j.sna.2011.08.019
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report a thin PVDF-TrFE (polyvinyledenedifluoride-trifluoroethylene) copolymer film pressure sensor, fabricated using standard lithography process for cost-effective batch process, film uniformity, and high resolution of polymer patterning. PVDF-TrFE copolymer, a semi-crystalline material, was spin-coated into thin films (1 mu m thick) to tap the near beta-phase formation. Pressure measurements demonstrated that the thin film (1 mu m) show better performance compared to thick film (6 mu m) with no electrical poling or mechanical stretching. Thin film devices showed higher beta phase formation from Raman spectroscopy measurements, which translate into high piezoelectricity for sensing. The sensors can operate over a broad pressure range of 0-300 mmHg, with fast recovery time of 0.17 s, suitable for real time flow measurements in catheter applications. Published by Elsevier B.V.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 13 条
  • [1] AN ULTRAMINIATURE SOLID-STATE PRESSURE SENSOR FOR A CARDIOVASCULAR CATHETER
    CHAU, HL
    WISE, KD
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1988, 35 (12) : 2355 - 2362
  • [2] INVESTIGATION OF 3-SURFACE PROPERTIES OF SEVERAL METALS AND THEIR RELATION TO BLOOD COMPATIBILITY
    DEPALMA, VA
    BAIER, RE
    GOTT, VL
    FORD, JW
    FURUSE, A
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1972, 6 (04): : 37 - &
  • [3] Furukawa T., 1988, MEASUREMENTS PROPERT, P65
  • [4] AN ULTRAMINIATURE CMOS PRESSURE SENSOR FOR A MULTIPLEXED CARDIOVASCULAR CATHETER
    JI, J
    CHO, ST
    ZHANG, Y
    NAJAFI, K
    WISE, KD
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1992, 39 (10) : 2260 - 2267
  • [5] A new method to measure heart rate with EMFi and PVDF materials
    Kärki, S.
    Lekkala, J.
    [J]. Journal of Medical Engineering and Technology, 2009, 33 (07) : 551 - 558
  • [6] Li C., 2010, APPL PHYS LETT, V96
  • [7] Flexible dome and bump shape piezoelectric tactile sensors using PVDF-TrFE copolymer
    Li, Chunyan
    Wu, Pei-Ming
    Lee, Soohyun
    Gorton, Andrew
    Schulz, Mark J.
    Ahn, Chong H.
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (02) : 334 - 341
  • [8] INTRAVASCULAR STENTS - TISSUE-STENT INTERACTIONS AND DESIGN CONSIDERATIONS
    PALMAZ, JC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 613 - 618
  • [9] Thirty-one years of clinical experience with "nuclear-powered" pacemakers
    Parsonnet, V
    Driller, J
    Cook, D
    Rizvi, SA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (02): : 195 - 200
  • [10] A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.
    Sandham, JD
    Hull, RD
    Brant, RF
    Knox, L
    Pineo, GF
    Doig, CJ
    Laporta, DP
    Viner, S
    Passerini, L
    Devitt, H
    Kirby, A
    Jacka, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (01) : 5 - 14