A Wi-Fi Cloud-Based Portable Potentiostat for Electrochemical Biosensors

被引:34
作者
Bianchi, Valentina [1 ]
Boni, Andrea [1 ]
Fortunati, Simone [2 ]
Giannetto, Marco [2 ]
Careri, Maria [2 ]
De Munari, Ilaria [1 ]
机构
[1] Univ Parma, Dept Engn & Architecture, I-43124 Parma, Italy
[2] Univ Parma, Dept Chem Life Sci & Environm Sustainabil, I-43124 Parma, Italy
关键词
Analog front end; cloud services; Internet of Things (IoT); portable potentiostat; Wi-Fi; ACID;
D O I
10.1109/TIM.2019.2928533
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurement of the analyte concentration in electrochemical biosensors traditionally requires costly laboratory equipment to obtain accurate results. Innovative portable solutions have recently been proposed, but usually, they lean on personal computers (PCs) or smartphones for data elaboration and they exhibit poor resolution or portability and proprietary software. This paper presents a low-cost portable system, assembling an ad hoc-designed analog front end (AFE) and a development board equipped with a system on chip integrating a microcontroller and a Wi-Fi network processor. The wireless module enables the transmission of measurements directly to a cloud service for sharing device outcome with users (physicians, caregivers, and so on). In doing so, the system does not require neither the customized software nor other devices involved in data acquisition. Furthermore, when any Internet connection is lost, the data are stored on board for subsequent transmission when a Wi-Fi connection is available. The noise output voltage spectrum has been characterized. Since the designed device is intended to be battery-powered to enhance portability, investigations about battery lifetime were carried out. Finally, data acquired with a conventional benchtop Autolab PGSTAT-204 electrochemical workstation are compared with the outcome of our developed device to validate the effectiveness of our proposal. To this end, we selected ferri/ferrocyanide as redox probe, obtaining the calibration curves for both the platforms. The final outcomes are shown to be feasible, accurate, and repeatable.
引用
收藏
页码:3232 / 3240
页数:9
相关论文
共 24 条
[1]   MiniStat: Development and Evaluation of a Mini-Potentiostat for Electrochemical Measurements [J].
Adams, Scott D. ;
Doeven, Egan H. ;
Quayle, Kim ;
Kouzani, Abbas Z. .
IEEE ACCESS, 2019, 7 :31903-31912
[2]   Open-Source Potentiostat for Wireless Electrochemical Detection with Smartphones [J].
Ainla, Alar ;
Mousavi, Maral P. S. ;
Tsaloglou, Maria-Nefeli ;
Redston, Julia ;
Bell, Jeffrey G. ;
Teresa Fernandez-Abedul, M. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2018, 90 (10) :6240-6246
[3]   A COTS-Based Portable System to Conduct Accurate Substance Concentration Measurements [J].
Aznar-Poveda, Juan ;
Antonio Lopez-Pastor, Jose ;
Garcia-Sanchez, Antonio-Javier ;
Garcia-Haro, Joan ;
Fernandez Otero, Toribio .
SENSORS, 2018, 18 (02)
[4]   A Plug and Play IoT Wi-Fi Smart Home System for Human Monitoring [J].
Bassoli, Marco ;
Bianchi, Valentina ;
De Munari, Ilaria .
ELECTRONICS, 2018, 7 (09)
[5]   An IoT Approach for an AAL Wi-Fi-Based Monitoring System [J].
Bassoli, Marco ;
Bianchi, Valentina ;
De Munari, Ilaria ;
Ciampolini, Paolo .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (12) :3200-3209
[6]   Optimization of the DPV potential waveform for determination of ascorbic acid on PEDOT-modified electrodes [J].
Bello, A. ;
Giannetto, M. ;
Mori, G. ;
Seeber, R. ;
Terzi, F. ;
Zanardi, C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) :430-435
[7]  
Bezuidenhout P, 2017, AFRICON, P83, DOI 10.1109/AFRCON.2017.8095460
[8]  
Chhorn S, 2018, 2018 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), P325
[9]   A low-cost miniaturized potentiostat for point-of-care diagnosis [J].
Cruz, Andres Felipe Diaz ;
Norena, Nicolas ;
Kaushik, Ajeet ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2014, 62 :249-254
[10]  
Dobbelaere T, 2017, HARDWAREX, V2, P34, DOI 10.1016/j.ohx.2017.08.001