R22 that has been used predominantly in air conditioning and in medium and low-temperature applications contains ozone depleting chlorine atoms and hence will be phased out eventually. This paper presents the experimental performance study of a split-air-conditioner using ozone friendly alternative refrigerants. The existing split-air-conditioner originally designed for R22 as the working fluid was retrofitted with R410A and R417A respectively, and the performance of the system was evaluated and compared with its performance when R22 was used. Experimental results showed that with R417A, the system had 1.9% higher refrigeration capacity and 14.2% lower with R410A when compared to that of R22. The average discharge pressure of the compressor obtained with R417A and R410A were 3.8% lower and 10.3% higher, respectively, than with R22. The lowest compressor power consumption and pressure ratio were obtained with the R417A retrofitted system. The average coefficient of performance (COP) obtained using R417A is 2.9% higher, while that of R410A is 8.4% lower than that of R22. Generally, with R417A the system consistently had the best performance in comparison to both R22 and R410A, indicating that R417A would be a better choice for retrofitting existing split-air-conditioners originally designed to use R22 as working fluid.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 21 条
  • [1] Performance investigation of ozone-friendly R404A and R507 refrigerants as alternatives to R22 in a window air-conditioner
    Bolaji, Bukola Olalekan
    ENERGY AND BUILDINGS, 2011, 43 (11) : 3139 - 3143
  • [2] A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners
    Chen, W.
    APPLIED THERMAL ENGINEERING, 2008, 28 (01) : 1 - 7
  • [3] Investigations on charge reduction strategies to use R290 as an alternative to R22 in a split air conditioner
    Saravanan, A. L.
    Murugan, R. S.
    Lal, D. M.
    EXPERIMENTAL HEAT TRANSFER, 2017, 30 (02) : 126 - 138
  • [4] Performance of air cooled heat pump Air Conditioner with Natural Refrigerant R1270 and R290 to Replace R22
    Chen, Jianbo
    Li, He
    Xi, Ling
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 484 - 487
  • [5] Thermodynamic Analysis of Ejector as an Expansion Device on Split-type Air Conditioner Using R410A as Working Fluid
    Sumeru
    Nasution, Henry
    An, Farid Nasir
    ADVANCES IN APPLIED MECHANICS AND MATERIALS, 2014, 493 : 227 - +
  • [6] Experimental Study on Pool Boiling Heat Transfer for R22, R407c, and R410a on a Horizontal Tube Bundle With Enhanced Tubes
    Li, Qianxia
    Zhang, Zhengguo
    Gao, Xuenong
    HEAT TRANSFER ENGINEERING, 2011, 32 (11-12) : 943 - 948
  • [7] Performance assessment of HCFC-22 window air conditioner retrofitted with R-407C
    Devotta, S
    Padalkar, AS
    Sane, NK
    APPLIED THERMAL ENGINEERING, 2005, 25 (17-18) : 2937 - 2949
  • [8] Artificial neural network models for depicting mass flow rate of R22, R407C and R410A through electronic expansion valves
    Saleh, B.
    Aly, Ayman A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 63 : 113 - 124
  • [9] EXPERIMENTAL RESEARCH OF R1234YF FOR REPALCING R22 USED IN A WINDOW-TYPE AIR CONDITIONER
    Jin, Tingxiang
    Xu, Ran
    Lv, Zijian
    3RD IIR CONFERENCE ON HFO REFRIGERANTS AND LOW GWP BLENDS, 2023, : 150 - 156
  • [10] Thermodynamic analysis of an air conditioner using R22/HC blend with TiO2/Mineral oil nanolubricant to retrofit R22/POE oil
    Razzaq, Moham Ed Abdur
    Ahamed, Jamal Uddin
    RESULTS IN ENGINEERING, 2020, 8