Stress distribution of two commercial dental implant systems: A three-dimensional finite element analysis

被引:45
作者
Chang, Hao-Sheng [1 ,2 ]
Chen, Yi-Chin [3 ]
Hsieh, Yao-Dung [1 ,4 ]
Hsu, Ming-Lun [5 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Dent, Kaohsiung, Taiwan
[2] Shu Zen Coll Med & Management, Kaohsiung, Taiwan
[3] Met Ind Res & Dev Ctr, Med Device & Optoelect Equipment Dept, Kaohsiung, Taiwan
[4] Natl Def Natl Med Ctr, Sch Dent, Taipei, Taiwan
[5] Natl Yang Ming Univ, Dept Dent, Taipei 112, Taiwan
关键词
dental implant; finite element analysis; platform switching; PLATFORM-SWITCHING TECHNIQUE; ORAL IMPLANTS; COMPACT-BONE; OCCLUSAL OVERLOAD; CORTICAL BONE; DESIGN; PROSTHESES; TISSUE; COMPLICATIONS; STABILITY;
D O I
10.1016/j.jds.2012.04.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: This study investigates the stress distributions in an implant, abutment, and crown restoration with different implant systems, in various bone qualities, and with different loading protocols using a three-dimensional finite element model. Materials and methods: Eight three-dimensional finite element models with 16 test conditions containing four types of dental implants embedded in two different bone qualities (types II and IV) under 100-N axial and 30 oblique loading forces were applied to analyze the stress distribution in the crown restoration, abutment, abutment screw, implant, and supporting bone. Results: The highest maximum von Mises stress was noted in the abutment of a tissue-level implant with the Straumann system (1203.04 MPa) under a 30 degrees oblique loading force. With axial load application, stresses in the screw and abutment of the NobelBiocare system were greater in the tissue-level implant (MK III) than in the bone-level implant (Active). The von Mises stresses in the cortical bone were mostly greater in the tissue-level implant (MK III) than in the bone-level implant (Active) of the NobelBiocare system. However, von Mises stresses in cancellous bone were mostly greater in the bone-level implant (Active) than in the tissue-level implant (MK III) of the NobelBiocare system. Conclusion: Within the limitations of the present study, the Straumann system produced greater stresses than the NobelBiocare system in type IV cortical bone, but they were almost equal in type II bone. By contrast, the NobelBiocare system produced greater stresses than the Straumann system in cancellous bone, regardless of the type of loading angle or bone quality. Copyright (C) 2013, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:261 / 271
页数:11
相关论文
共 42 条
[11]   Clinical complications with implants and implant prostheses [J].
Goodacre, CJ ;
Bernal, G ;
Rungcharassaeng, K ;
Kan, JYK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :121-132
[12]   COMPRESSIVE FATIGUE BEHAVIOR OF BOVINE COMPACT BONE [J].
GRAY, RJ ;
KORBACHER, GK .
JOURNAL OF BIOMECHANICS, 1974, 7 (03) :287-+
[13]   3-DIMENSIONAL FINITE-ELEMENT ANALYSIS OF GLASS CERAMIC DENTAL CROWNS [J].
HOJJATIE, B ;
ANUSAVICE, KJ .
JOURNAL OF BIOMECHANICS, 1990, 23 (11) :1157-1166
[14]  
Holmgren E P, 1998, J Oral Implantol, V24, P80, DOI 10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO
[15]  
2
[16]  
Hoshaw SJ., 1994, INT J ORAL MAXILLOFA, V9, P345
[17]  
Hsu ML, 2007, INT J ORAL MAX IMPL, V22, P301
[18]  
Huang HM, 2001, J MED BIOL ENG, V21, P61
[19]   Loss of osseointegration caused by occlusal load of oral implants - A clinical and radiographic study in monkeys [J].
Isidor, F .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (02) :143-152
[20]   Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation [J].
Isidor, F .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (01) :1-9