Invasive assessment of the coronary microcirculation - Superior reproducibility and less hemodynamic dependence of index of microcirculatory resistance compared with coronary flow reserve

被引:347
作者
Ng, MKC
Yeung, AC
Fearon, WF
机构
[1] Stanford Univ, Med Ctr, Div Cardiovasc Med, Stanford, CA 94305 USA
[2] Royal Prince Alfred Hosp, Dept Cardiol, Sydney, NSW, Australia
关键词
microcirculation; pressure; coronary disease;
D O I
10.1161/CIRCULATIONAHA.105.603522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - A simple, reproducible invasive method for assessing the coronary microcirculation is lacking. A novel index of microcirculatory resistance (IMR) has been shown in animals to correlate with true microvascular resistance and, unlike coronary flow reserve (CFR), to be independent of the epicardial artery. We sought to compare the reproducibility and hemodynamic dependence of IMR with CFR in humans. Methods and Results - Using a pressure-temperature sensor-tipped coronary wire, thermodilution-derived CFR and IMR were measured, along with fractional flow reserve (FFR), in 15 coronary arteries (15 patients) under the following hemodynamic conditions: (1) twice at baseline; (2) during right ventricular pacing at 110 bpm; (3) during intravenous infusion of nitroprusside; and (4) during intravenous dobutamine infusion. Mean CFR did not change during baseline measurements or during nitroprusside infusion but decreased during pacing (from 3.1 +/- 1.1 at baseline to 2.3 +/- 1.2 during pacing, P < 0.05) and during dobutamine infusion (from 3.0 +/- 1.0 to 1.7 +/- 0.6 with dobutamine, P < 0.0001). By comparison, mean values for IMR and FFR remained similar throughout all hemodynamic conditions. The mean coefficient of variation between 2 baseline measurements was significantly lower for IMR (6.9 +/- 6.5%) and FFR (1.6 +/- 1.6%) than for CFR (18.6 +/- 9.6%; P < 0.01). Mean correlation between baseline measurements and each hemodynamic intervention was superior for IMR (r = 0.90 +/- 0.05) and FFR (r = 0.86 +/- 0.12) compared with CFR (r = 0.70 +/- 0.05; P < 0.05). Conclusions - Compared with CFR, IMR provides a more reproducible assessment of the microcirculation, which is independent of hemodynamic perturbations. Simultaneous measurement of FFR and IMR may provide a comprehensive and specific assessment of coronary physiology at both epicardial and microvascular levels, respectively.
引用
收藏
页码:2054 / 2061
页数:8
相关论文
共 21 条
[1]   Epicardial stenosis severity does not affect minimal microcirculatory resistance [J].
Aarnoudse, W ;
Fearon, WF ;
Manoharan, G ;
Geven, M ;
van de Vosse, F ;
Rutten, M ;
De Bruyne, B ;
Pijls, NHJ .
CIRCULATION, 2004, 110 (15) :2137-2142
[2]   Association between coronary lesion severity and distal microvascular resistance in patients with coronary artery disease [J].
Chamuleau, SAJ ;
Siebes, M ;
Meuwissen, M ;
Koch, KT ;
Spaan, JAE ;
Piek, JJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (05) :H2194-H2200
[3]  
Chilian WM, 1997, CIRCULATION, V95, P522
[4]   Coronary thermodilution to assess flow reserve - Experimental validation [J].
De Bruyne, B ;
Pijls, NHJ ;
Smith, L ;
Wievegg, M ;
Heyndrickx, GR .
CIRCULATION, 2001, 104 (17) :2003-2006
[5]   Simultaneous coronary pressure and flow velocity measurements in humans - Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve [J].
deBruyne, B ;
Bartunek, J ;
Sys, SU ;
Pijls, NHJ ;
Heyndrickx, GR ;
Wijns, W .
CIRCULATION, 1996, 94 (08) :1842-1849
[6]   Microvascular resistance is not influenced by epicardial coronary artery stenosis severity - Experimental validation [J].
Fearon, WF ;
Aarnoudse, W ;
Pijls, NHJ ;
De Bruyne, B ;
Balsam, LB ;
Cooke, DT ;
Robbins, RC ;
Fitzgerald, PJ ;
Yeung, AC ;
Yock, PG .
CIRCULATION, 2004, 109 (19) :2269-2272
[7]   Comparison of coronary thermodilution and Doppler velocity for assessing coronary flow reserve [J].
Fearon, WF ;
Farouque, HMO ;
Balsam, LB ;
Cooke, DT ;
Robbins, RC ;
Fitzgerald, PJ ;
Yeung, AC ;
Yock, PG .
CIRCULATION, 2003, 108 (18) :2198-2200
[8]   Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients - Physiologic investigation for transplant arteriopathy (PITA study) [J].
Fearon, WF ;
Nakamura, M ;
Lee, DP ;
Rezaee, M ;
Vagelos, RH ;
Hunt, SA ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 108 (13) :1605-1610
[9]   Novel index for invasively assessing the coronary microcirculation [J].
Fearon, WF ;
Balsam, LB ;
Farouque, HMO ;
Robbins, RC ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 107 (25) :3129-3132
[10]   MECHANISMS OF DISEASE - THE PATHOGENESIS OF CORONARY-ARTERY DISEASE AND THE ACUTE CORONARY SYNDROMES .1. [J].
FUSTER, V ;
BADIMON, L ;
BADIMON, JJ ;
CHESEBRO, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (04) :242-250