Wavelet denoising of displacement estimates in elastography

被引:35
作者
Techavipoo, U
Varghese, T
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
关键词
elastography; elastogram; elasticity; imaging; modulus; strain; ultrasound; wavelet shrinkage; denoising; discrete wavelet transform; radiofrequency ablation;
D O I
10.1016/j.ultrasmedbio.2003.11.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Wavelet shrinkage denoising of the displacement estimates to reduce noise artefacts, especially at high overlaps in elastography, is presented in this paper. Correlated errors in the displacement estimates increase dramatically with an increase in the overlap between the data segments. These increased correlated errors (due to the increased correlation or similarity between consecutive displacement estimates) generate the so-called "worm" artefact in elastography. However, increases in overlap on the order of 90% or higher are essential to improve axial resolution in elastography. The use of wavelet denoising significantly reduces errors in the displacement estimates, thereby reducing the worm artefacts, without compromising on edge (high-frequency or detail) information in the elastogram. Wavelet denoising is a term used to characterize noise rejection by thresholding the wavelet coefficients. Worm artefacts can also be reduced using a low-pass filter; however, low-pass filtering of the displacement estimates does not preserve local information such as abrupt change in slopes, causing the smoothing of edges in the elastograms. Simulation results using the analytic 2-D model of a single inclusion phantom illustrate that wavelet denoising produces elastograms with the closest correspondence to the ideal mechanical strain image. Wavelet denoising applied to experimental data obtained from an in vitro thermal lesion phantom generated using radiofrequency (RF) ablation also illustrates the improvement in the elastogram noise characteristics. (E-mail: tvarghese@wisc.edu) (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:477 / 491
页数:15
相关论文
共 49 条
[1]   Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography [J].
Alam, SK ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :95-105
[2]   An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[3]   Elastographic axial resolution criteria: An experimental study [J].
Alam, SK ;
Ophir, J ;
Varghese, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :304-309
[4]  
ANDERSON WAD, 1953, PATHOLOGY
[5]  
[Anonymous], 1998, Wavelet Analysis: the Scalable Structure of Information
[6]  
[Anonymous], 1997, A Wavelet Tour of Signal Processing
[7]  
Bamber JC, 1996, ACOUST IMAG, V22, P285
[8]  
BERTRAND M, 1989, IEEE ULTRASON FERROE, V2, P859
[9]   Error analysis in acoustic elastography .2. Strain estimation and SNR analysis [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1147-1154
[10]   Target detectability in acoustic elastography [J].
Bilgen, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) :1128-1133