Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone

被引:55
作者
Hawks, Michael A. [1 ]
Kim, Hyunchul [2 ]
Strauss, Joseph E. [1 ]
Oliphant, Bryant W. [1 ]
Golden, Robert D. [1 ]
Hsieh, Adam H. [2 ]
Nascone, Jason W. [1 ]
O'Toole, Robert V. [1 ]
机构
[1] Univ Maryland, Sch Med, R Adams Cowley Shock Trauma Ctr, Dept Orthopaed, Baltimore, MD 21201 USA
[2] Univ Maryland, Fischell Dept Bioengn, Orthopaed Mechanobiol Lab, College Pk, MD 20742 USA
关键词
Trochanteric lag screw; Inverted triangle construct; Femoral neck fracture;
D O I
10.1016/j.clinbiomech.2013.08.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: We assessed the biomechanical performances of a trochanteric lag screw construct and a traditional inverted triangle construct in the treatment of simulated Pauwels type 3 femoral neck fractures. Methods: An inverted triangle construct (three 7.3-mm cannulated screws placed in inverted triangle orientation) and a trochanteric lag screw construct (two 7.3-mm cannulated screws placed across the superior portion of the femoral neck and one 4.5-mm lag screw placed perpendicular to the fracture in superolateral to inferomedial orientation) were tested in nine matched pairs of non-osteoporotic human cadaveric femora. We used a previously described vertically oriented femoral neck fracture model and testing protocol that incrementally loaded the constructs along the mechanical axis of the femur to 1400 N. Specimens that survived incremental loading underwent cyclic loading. Apparent construct stiffness, force at 3 mm of displacement, and survival of incremental loading were recorded. Findings: The trochanteric lag screw group had a 70% increase in stiffness (261 N/mm [29 standard deviation] versus 153 N/mm [16 standard deviation]; P = 0.026) and a 43% increase in force required for displacement (620 N versus 435 N; P = 0.018) compared with the inverted triangle group. One trochanteric lag screw and no inverted triangle specimen survived incremental loading. Interpretation: A trochanteric lag screw construct applied to vertically oriented femoral neck fractures provides marked improvement in mechanical performance compared with the inverted triangle construct. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:886 / 891
页数:6
相关论文
共 32 条
  • [21] Biomechanical comparison of fixation methods on third-generation femoral composite bone models in Pauwels type 3 femoral neck fractures: Contribution of the medial buttress plate to fixation
    Kilic, Feyzi
    Polat, Abdulkadir
    Yamak, Fatih
    Bozdag, Ergun
    Fidan, Firat
    Basar, Hakan
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2023, 57 (05) : 243 - 249
  • [22] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Jichao Liu
    Zhengwei Li
    Jie Ding
    Bingzhe Huang
    Chengdong Piao
    [J]. BMC Musculoskeletal Disorders, 23
  • [23] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Liu, Jichao
    Li, Zhengwei
    Ding, Jie
    Huang, Bingzhe
    Piao, Chengdong
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [24] Biomechanical evaluation of two modified intramedullary fixation system for treating unstable femoral neck fractures: A finite element analysis
    Huang, Qiang
    Zhang, CongMing
    Bai, HuanAn
    Wang, Qian
    Li, Zhong
    Lu, Yao
    Ma, Teng
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [25] Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis
    Adamovic, Petra
    Kodvanj, Janos
    Blazevic, Dejan
    Sabalic, Srecko
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (05) : 1005 - 1015
  • [26] Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis
    Petra Adamović
    Janoš Kodvanj
    Dejan Blažević
    Srećko Sabalić
    [J]. Medical & Biological Engineering & Computing, 2023, 61 : 1005 - 1015
  • [27] In vitro biomechanical analysis of a locking self-compression screw model applied to Pauwels III and comminuted femoral neck fractures
    de Oliveira, Matheus Moreno
    Freitas, Anderson
    Giordano, Vincenzo
    da Costa Moura, Carlos Magno
    Ferreira, Breno Lima
    Lucas, Luan de Gois
    Pires, Robinson Esteves
    Belangero, William Dias
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [28] Parallel and non-parallel cannulated screw fixation complications in femoral neck fractures: A systematic review and meta-analysis
    Lim, Eic Ju
    Kim, Beom-Su
    Kim, Chul-Ho
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (06)
  • [29] Biomechanical study of a biplanar double support screw (BDSF) technique based on Pauwels angle in femoral neck fractures: finite element analysis
    Tang, Zhongjian
    Zhang, Yazhong
    Huang, Shaolong
    Zhu, Zhexi
    Zhou, Chengqiang
    Zhu, Ziqiang
    Wang, Yunqing
    Wang, Bin
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [30] Gamma Nail Combined with One Cannulated Compression Screw Fixation for Treating Pauwels Type III Femoral Neck Fractures in Young and Middle-Aged Adults: Clinical Follow-Up and Biomechanical Studies
    Wen, Qiangqiang
    Gu, Feng
    Su, Zilong
    Zhang, Ke
    Xie, Xiaoping
    Li, Jiangbi
    Sui, Zhenjiang
    Yu, Tiecheng
    [J]. ORTHOPAEDIC SURGERY, 2023, 15 (04) : 1045 - 1052